The 2016 Central Italy seismic sequence: linear and non-linear interpretation models for damage evolution in S. Agostino’s church in Amatrice

被引:0
|
作者
M. Acito
M. S. Garofane
E. Magrinelli
G. Milani
机构
[1] Politecnico di Milano,Department of Architecture, Built Environment and Construction Engineering
[2] Politecnico di Milano,undefined
来源
Bulletin of Earthquake Engineering | 2021年 / 19卷
关键词
2016–2017 Italy seismic sequence; Strong-motion parameters; Historical masonry buildings; 3D finite elements; Non-linear dynamic analysis; Damage analysis;
D O I
暂无
中图分类号
学科分类号
摘要
An extensive numerical investigation of the structural behavior of the masonry church of Sant’Agostino in Amatrice (Italy) during the 2016–2017 seismic sequence is presented. The seismic performance of the church is studied in relation to the most energetic shocks of the sequence, occurred on August 24th, 2016, and October 30th, 2016, whose seismic parameters (PGA, Trifunac duration, Arias intensity, destructiveness potential factor) are analyzed in detail. In particular, a comparison between ground motion data recorded by different stations is presented in order to evaluate the influence of local amplification effects on the structural behavior. To achieve this goal, the ground motion data recorded by the permanent accelerometric station (AMT) located in Amatrice on type B soil and belonging to the National Accelerometric Network (RAN) are firstly considered. Then, they are critically compared with those provided by an accelerometric station temporarily installed after the first main shock in the downtown area close to the church site, showing a clear amplification due to the site effects. The dynamic behavior of S. Agostino’s church is numerically investigated by carrying out a set of non-linear dynamic analyses on the 3D finite element model of the church developed in Abaqus CAE and considering as seismic input both the accelerograms recorded by the AMT fixed station and those including the local amplification effects. Non-linear properties of materials are taken into account by defining an elasto-plastic constitutive law with reasonable damage parameters in tension. Numerical results are evaluated in terms of displacement time-history of some relevant control points located on the masonry walls and maps of tensile damage cumulated at the end of the simulations. Numerical results are in good agreement with the evidence based behavior of the structure, thus validating numerical simulations as effective tools for seismic analysis of masonry buildings. Furthermore, a hypothetical strengthening intervention concerning the improvement in masonry mechanical properties is implemented in the model to investigate its positive role in preventing collapse. In the latter case, the approach provides useful hints in interpreting the behavior of the church under the application of repeated accelerograms.
引用
收藏
页码:1467 / 1507
页数:40
相关论文
共 47 条
  • [1] The 2016 Central Italy seismic sequence: linear and non-linear interpretation models for damage evolution in S. Agostino's church in Amatrice
    Acito, M.
    Garofane, M. S.
    Magrinelli, E.
    Milani, G.
    BULLETIN OF EARTHQUAKE ENGINEERING, 2021, 19 (03) : 1467 - 1507
  • [2] Seismic sequence of 2016-17: Linear and non-linear interpretation models for evolution of damage in San Francesco church, Amatrice
    Jain, Avni
    Acito, Maurizio
    Chesi, Claudio
    ENGINEERING STRUCTURES, 2020, 211
  • [3] MULTITEMPORAL 3D MODELLING FOR CULTURAL HERITAGE EMERGENCY DURING SEISMIC EVENTS: DAMAGE ASSESMENT OF S. AGOSTINO CHURCH IN AMATRICE (RI)
    Chiabrando, F.
    Di Lolli, A.
    Patrucco, G.
    Spano, A.
    Sammartano, G.
    Lose, L. Teppati
    GEOMATICS & RESTORATION - CONSERVATION OF CULTURAL HERITAGE IN THE DIGITAL ERA, 2017, 42-5 (W1): : 69 - 76
  • [4] Damage Assessment by Numerical Modeling of Sant'Agostino's Sanctuary in Offida During the Central Italy 2016-2017 Seismic Sequence
    Giordano, Ersilia
    Clementi, Francesco
    Nespeca, Andrea
    Lenci, Stefano
    FRONTIERS IN BUILT ENVIRONMENT, 2019, 4
  • [5] Damage Assessment by the Non-Smooth Contact Dynamics Method of the Iconic Crumbling Of the Clock Tower in Amatrice after the 2016 Central Italy Seismic Sequence
    Clementi, Francesco
    Milani, Gabriele
    Gazzani, Valentina
    Poiani, Marina
    Lenci, Stefano
    INTERNATIONAL CONFERENCE ON NUMERICAL ANALYSIS AND APPLIED MATHEMATICS (ICNAAM-2018), 2019, 2116
  • [6] The theory of the S-N fatigue damage envelope: Generalization of linear, double-linear, and non-linear fatigue damage models
    Pavlou, Dimitrios G.
    INTERNATIONAL JOURNAL OF FATIGUE, 2018, 110 : 204 - 214
  • [7] S-AMP for Non-linear Observation Models
    Cakmak, Burak
    Winther, Ole
    Fleury, Bernard H.
    2015 IEEE INTERNATIONAL SYMPOSIUM ON INFORMATION THEORY (ISIT), 2015, : 2807 - 2811
  • [8] Theoretical models and recorded response in the estimation of cumulative seismic damage on non-linear structures
    Heredia-Zavoni, E.
    Zeballos, A.
    Esteva, L.
    Earthquake Engineering and Structural Dynamics, 2000, 29 (12) : 1779 - 1796
  • [9] Theoretical models and recorded response in the estimation of cumulative seismic damage on non-linear structures
    Heredia-Zavoni, E
    Zeballos, A
    Esteva, L
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2000, 29 (12): : 1779 - 1796
  • [10] Forecast of Chile's tourism demand based on linear and non-linear seasonal models
    Colther, Cristian
    Arriagada-Millaman, Ailin
    PASOS-REVISTA DE TURISMO Y PATRIMONIO CULTURAL, 2021, 19 (02) : 323 - 336