On-line adaptive repetitive controller for power factor correction systems

被引:0
作者
Ju J. [1 ]
Liu B. [1 ]
Li J. [1 ]
Hu Z. [1 ]
Wan H. [1 ]
机构
[1] School of Information Engineering, Nanchang Hangkong University, Nanchang
关键词
adaptive repetitive controller; frequency shifting; harmonics;
D O I
10.1007/s12204-016-1721-4
中图分类号
学科分类号
摘要
When the fundamental frequency is shifting, it is hard for traditional repetitive controller to work at the resonant frequencies. In this paper, a novel adaptive repetitive controller for power factor correction systems is proposed to suppress the current harmonics. Through the controller, the shifting sampling times of the repetitive controller in a fundamental period can be obtained. Mathematical analysis, simulations and physical experiments have validated the effectiveness of the adaptive repetitive controller. © 2016, Shanghai Jiaotong University and Springer-Verlag Berlin Heidelberg.
引用
收藏
页码:263 / 269
页数:6
相关论文
共 10 条
[1]  
Wei Z., Chen X., Chen J., Et al., Input current phase lag and closed loop compensation for three-phase PFC rectifiers based on one-cycle control strategy [J], Proceedings of the CSEE, 33, 33, pp. 42-49, (2013)
[2]  
Wei W., Research on harmonic technology [J], Electrical Engineering, 35, 6, pp. 19-23, (2009)
[3]  
Zhang P.G., Li X.Y., Li Z., Research on frequency stability and control strategy in isolated power grid [J], Power System Protection and Control, 40, 15, pp. 143-149, (2012)
[4]  
Wang C.K., Yin H.J., System design and PI parameter calibration of three-phase voltage source PWM rectifier [J], Electric Drive, 41, 3, pp. 41-45, (2011)
[5]  
Zhang W., Wang W.Y., He Y.K., Parameter design of voltage source converter under unbalance grid voltage [J], Automation of Electric Power Systems, 36, 2, pp. 91-95, (2012)
[6]  
Liu B., Xie J.J., Xu H.B., Et al., Novel grid-connected control strategies based on self-adaptive proportional resonant [J], Transactions of China Electrotechnical Society, 28, 9, pp. 186-195, (2011)
[7]  
Li Y.T., Lu H.F., Qu W.L., Et al., Improved repetitive control for inverter current harmonics suppression [J], Journal of Tsinghua University (Science and Technology), 53, 7, pp. 1030-1035, (2013)
[8]  
Geng P., Dai K., Wei X.L., Et al., The repetitive control algorithm based current waveform correction for shunt active power filter [J], Transactions of China Electrotechnical Society, 22, 2, pp. 127-131, (2007)
[9]  
Yan Y.Z., Guo L.P., Huang Z., Et al., 3-phase power factor correction based on harmonic injection [J], Microelectronics, 38, 1, pp. 96-99, (2008)
[10]  
Wei Y.F., Zhao L.H., Rong X.L., The isolate 100 kW PV inverter based on double-loop control and repetitive control [J], Renewble Energy Resources, 30, 4, pp. 6-9, (2012)