Determination of selenium in sediment by isotope-dilution inductively coupled plasma mass spectrometry with an octapole reaction cell

被引:0
作者
Kazumi Inagaki
Akiko Takatsu
Atsuko Nakama
Sakae Eyama
Takashi Yarita
Kensaku Okamoto
Koichi Chiba
机构
[1] National Institute of Advanced Industrial Science and Technology,Environmental Standards Section, National Metrology Institute of Japan (NMIJ)
来源
Analytical and Bioanalytical Chemistry | 2006年 / 385卷
关键词
Selenium; Sediment; Isotope dilution; ICPMS; Cation-exchange disk filtration;
D O I
暂无
中图分类号
学科分类号
摘要
A method is described for determination of selenium in sediment by isotope-dilution inductively coupled plasma mass spectrometry with an octapole reaction cell (ID–ICP–ORCMS). Sediment samples were digested with HNO3, HClO4, and HF, and the digestion included an elaborate evaporation process to remove bromine from the digested solution. Simple strong cation-exchange disk filtration was used to remove rare earth elements (REE) from the digested solution, because REE2+ seriously interfere with Se isotopes (i.e. 156Gd2+ with 78Se+, 160Gd2+ with 80Se+). Addition of acetic acid to the filtrate was examined to improve the sensitivity of ICP–ORCMS measurement of Se+ by means of a carbon-enhancement effect. The interfering \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$Ar_{2}^{ + }$$\end{document} for selenium isotopes were almost eliminated by use of H2 as reaction gas. Interference from BrH+ formed in the reaction cell was negligible because the Br was removed in the evaporation process. Approximately 99.5% of REE were removed by cation-exchange disk filtration yet more than 99% of Se remained in the filtrate solution. The intensity for Se+ was enhanced approximately fourfold by addition of 5% (v/v) of acetic acid whereas that for \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$Ar^{ + }_{2}$$\end{document} was barely enhanced. Measured 80Se/78Se ratios in unspiked digested solutions of the sample were in good agreement with that for an Se standard solution. The analytical results for Se in the certified reference materials MESS-3 and PACS-1 were in good agreement with their certified values, with small uncertainties.
引用
收藏
页码:67 / 75
页数:8
相关论文
共 127 条
[1]  
Navarro-Alarcón M(2003)undefined Sci Total Environ 249 347-371
[2]  
López-Martínez MC(1996)undefined Environ Sci Technol 31 1419-1425
[3]  
Tokunaga TK(1999)undefined Fresenius J Anal Chem 364 521-526
[4]  
Brown GE(1987)undefined Spectrochim Acta B43 413-420
[5]  
Pickering IJ(2000)undefined Fresenius J Anal Chem 368 362-1374
[6]  
Sutton SR(2001)undefined J Anal At Spectrom 16 1370-288
[7]  
Bajt S(2001)undefined J Anal At Spectrom 16 285-453
[8]  
Townsend AT(1999)undefined Spectrochim Acta B54 443-124
[9]  
McLaren JW(2005)undefined Spectrochim Acta B60 117-708
[10]  
Beauchemin D(1989)undefined Anal Chem 61 701-729