Utilising of water hammer effect for surface roughening of Ti6Al4V

被引:0
作者
Dagmar Klichova
Akash Nag
Jakub Poloprudský
Josef Foldyna
Frank Pude
Libor Sitek
Sergej Hloch
机构
[1] Institute of Geonics,The Czech Academy of Sciences
[2] VSB-Technical University of Ostrava,Faculty of Mechanical Engineering
[3] Institute of Physics of Materials,Faculty of Manufacturing Technologies
[4] Czech Academy of Sciences,undefined
[5] Institute of Machine Tools and Manufacturing (IWF),undefined
[6] ETH Zürich,undefined
[7] Steinbeis High-Pressure Waterjet Technology Consulting Centre,undefined
[8] Technical University of Kosice with a seat in Presov,undefined
来源
The International Journal of Advanced Manufacturing Technology | 2023年 / 126卷
关键词
Surface activation; Implants; Pulsating water jet; Titanium alloy; Surface roughness; Trabecular shape;
D O I
暂无
中图分类号
学科分类号
摘要
There are many technological ways to activate biocompatible surfaces, but in some cases, there are not reliable for elderly patients. It has been found that surfaces created using pulsating water jets have a structure similar to trabecular bone structures. Such a similar shape to the endoprosthesis stems would enable faster fixation. The paper presents a novel way of utilizing the water hammer effect caused by forced multiple droplet impingement with a spatial frequency of 40,000 i/s on Ti6Al4V titanium alloy surface under different technological conditions. The objective was to create a structured surface with desired values of surface profile parameters Ra and Rz to increase the possible potential for implant osseointegration, fixation and stability. Pulsating water jet was generated at pressures from 20 to 100 MPa using a circular nozzle with a diameter of 1.32 mm. Two different strategies of the jet trajectory, namely linear and cross-hatch strategy, were investigated. Results were compared with grit blasted followed by plasma spray-coated femoral stem for cementless total hip arthroplasty. It has been found that variation in the input parameters results in significant changes in the surface generated. Samples whose surfaces were generated using energy intensity lower than 5 KJ/mm2 and have surface roughness in the range Ra = 4 – 8 μm were selected for surface topography and morphology analysis along with the commercial femoral stem. SEM analysis revealed the absence of foreign contamination and steeper surface heights on pulsating water jet treated samples compared to standard femoral prosthetic. The cross-section images showed the presence of sub-surface voids and craters of different sizes due to the jet's action. Surface topology is similar to trabecular shape. This indicates that roughening the surface increases the surface area and thus has potential bone tissue ingrowth during osseointegration.
引用
收藏
页码:5633 / 5647
页数:14
相关论文
共 181 条
[1]  
Kieswetter K(1996)The role of implant surface characteristics in the healing of bone Crit Rev Oral Biol Med 7 329-345
[2]  
Schwartz Z(2015)The effect of titanium surface modifications on dental implant osseointegration Biomater Oral Craniomaxillofacial Appl 17 62-77
[3]  
Dean DD(2009)Effects of titanium surface topography on bone integration: a systematic review Clin Oral Implants Res 20 172-184
[4]  
Boyan BD(2017)Implant surface roughness and patient factors on long-term peri-implant bone loss Periodontol 2000 218-227
[5]  
Annunziata M(2015)On the mechanical integrity of retrieved dental implants J Mech Behav Biomed Mater 49 290-299
[6]  
Guida L(2014)Differential regulation of osteogenic differentiation of stem cells on surface roughness gradients Biomaterials 35 9023-9032
[7]  
Wennerberg A(2012)The influence of surface treatment on the implant roughness pattern J Appl Oral Sci 20 550-555
[8]  
Albrektsson T(2007)On the relationship between common amplitude surface roughness parameters and surface area: Implications for the study of cell–material interactions Int Biodeterior Biodegradation 59 245-251
[9]  
De Bruyn H(2000)Waterjet machining and peening of metals J Press Vessel Technol 122 90-95
[10]  
Christiaens V(2007)Surface treatments of titanium dental implants for rapid osseointegration Dent Mater 23 844-854