Reusable immunomagnetic beads in an enzyme immunoassay

被引:0
|
作者
F. C. Han
J. Luo
H. F. Guo
W. H. Zhang
D. C. He
X. J. Yan
机构
[1] The Fourth Military Medical University,Institute of Genetic Diagnosis
[2] The Fourth Military Medical University,State Key Laboratory of Cancer Biology
[3] Beijing Normal University,Institute of Life Science
来源
World Journal of Microbiology and Biotechnology | 2007年 / 23卷
关键词
Epitope; Multiple antigen peptides; Immunomagnetic beads; Antibody; Enzyme immunoassay;
D O I
暂无
中图分类号
学科分类号
摘要
Multiple antigen peptides (MAPs) were synthesized according to the epitope sequence of human cytomegalovirus phosphoprotein pp150 and used as antigens to coat the surface of Dynabeads M-450 Tosylactivated covalently. The coating efficiency peaked at 79% when the concentration of MAP8 was 100 μg/ml. Based on the immunomagnetic beads, an enzyme immunoassay was established to detect anti-MAP8 immunoglobulin G in sera of Balb/c mice, which were immunized with MAP8. We showed in this study that, with optimized working conditions, the immunomagnetic beads could be regenerated after removal of the antibody complexes from their surface with 0.2 M citric acid buffer (pH 2.5) and reused at least 16 times without significantly influencing the antibody binding efficiency. The results suggest the possibility of developing reusable immuno-diagnostic kits in the near future.
引用
收藏
页码:1041 / 1045
页数:4
相关论文
共 50 条
  • [31] STROPHANTHIN-K DETERMINATION BY ENZYME-IMMUNOASSAY USING ANTIBODIES IMMOBILIZED ON ACTIVATED POLYSTYRENE BEADS
    TARUN, EI
    SAVENKOVA, MI
    METELITSA, DI
    JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 48 (01) : 106 - 109
  • [32] SHAKING POLYSTYRENE BEADS DURING COATING WITH ANTIBODY - EFFECT ON THE PRECISION PROFILE OF ENZYME-IMMUNOASSAY OF TRIIODOTHYRONINE
    KOTHARI, K
    SIVAPRASAD, N
    MANI, RS
    CLINICAL CHEMISTRY, 1989, 35 (04) : 701 - 701
  • [33] SANDWICH ENZYME-IMMUNOASSAY OF HUMAN CHORIONIC-GONADOTROPIN USING POLYSTYRENE BEADS AS SOLID SUPPORT
    GUPTA, SK
    GUESDON, JL
    AVRAMEAS, S
    TALWAR, GP
    ANNALES DE L INSTITUT PASTEUR-IMMUNOLOGY, 1985, D136 (01): : 47 - 55
  • [34] REUSABLE CDNA LIBRARIES COUPLED TO MAGNETIC BEADS
    LEE, YH
    VACQUIER, VD
    ANALYTICAL BIOCHEMISTRY, 1992, 206 (01) : 206 - 207
  • [35] Fullerene-ccated beads as reusable catalysts
    Jensen, AW
    Daniels, C
    JOURNAL OF ORGANIC CHEMISTRY, 2003, 68 (02): : 207 - 210
  • [36] Enhanced Competitive Immunomagnetic Beads Assay Assisted with PAMAM-Gold Nanoparticles Multi-Enzyme Probes for Detection of Deoxynivalenol
    Zeng, Kun
    Yang, Jian
    Su, Hao
    Yang, Sheng
    Gu, Xinkai
    Zhang, Zhen
    Zhao, Hongjun
    BIOSENSORS-BASEL, 2023, 13 (05):
  • [37] Preparation of reusable enzyme strips using alkylamine and arylamine glass beads affixed on plastic strips for urea determination
    Sharma, Minakshi
    Kumar, Vijay
    Kumar, Jitender
    Pundir, C. S.
    INDIAN JOURNAL OF CHEMICAL TECHNOLOGY, 2009, 16 (04) : 357 - 360
  • [38] Application of an automated immunomagnetic separation-enzyme immunoassay for the detection of Salmonella enterica subspecies enterica from poultry environmental swabs
    Leon-Velarde, Carlos G.
    Zosherafatein, Leila
    Odumeru, Joseph A.
    JOURNAL OF MICROBIOLOGICAL METHODS, 2009, 79 (01) : 13 - 17
  • [39] Application of an automated immunomagnetic separation-enzyme immunoassay for the detection of Salmonella spp. during an outbreak associated with a retail premises
    Duncanson, P
    Wareing, DRA
    Jones, O
    LETTERS IN APPLIED MICROBIOLOGY, 2003, 37 (02) : 144 - 148
  • [40] A rapid immunomagnetic-bead-based immunoassay for triazophos analysis
    Du, Pengfei
    Jin, Maojun
    Yang, Lihua
    Du, Xinwei
    Chen, Ge
    Zhang, Chan
    Jin, Fen
    Shao, Hua
    She, Yongxin
    Wang, Shanshan
    Zheng, Lufei
    Wang, Jing
    RSC ADVANCES, 2015, 5 (99) : 81046 - 81051