Biomechanical changes in the proximal femur before and after removal of femoral neck system

被引:0
|
作者
Nan, Chong [1 ]
Liu, Yuxiu [1 ]
Zhang, Di [2 ]
Qin, Yazhuo [1 ]
Yu, Hetong [1 ]
Ma, Zhanbei [1 ]
机构
[1] Baoding 1 Cent Hosp, Dept Orthoped, Baoding 071000, Hebei, Peoples R China
[2] Hebei Med Univ, Hosp 3, Dept Spinal Surg, Shijiazhuang 050000, Hebei, Peoples R China
来源
JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH | 2024年 / 19卷 / 01期
关键词
Femoral neck system; Cannulated screw removal; Biomechanical effect; Finite element analysis; FINITE-ELEMENT-ANALYSIS; FRACTURE;
D O I
10.1186/s13018-024-04769-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background As an innovative internal fixation system, FNS (femoral neck system) is increasingly being utilized by surgeons for the treatment of femoral neck fractures. At present, there have been numerous finite element analysis experiments studying the immediate stability of FNS and CSS in treating femoral neck fractures. However, there is scarce mechanical analysis available regarding the effects post internal fixation removal. This study aimed to investigate the alterations in mechanical parameters of the proximal femur before and after the removal of FNS (femoral neck system), and to assess potential distinctions in indicators following the extraction of CSS (Cannulated Screws).Methods A proximal femur model was reconstructed using finite element numerical techniques. The models for CSS and FNS were formulated utilizing characteristics and parametric definitions. The internal fixation was combined with a normal proximal femur model to simulate the healing state after fracture surgery. Within the framework of static analysis, consistent stress burdens were applied across the entirety of the models. The total deformation and equivalent stress of the proximal femur were recorded before and after the removal of internal fixation.Results Under the standing condition, the total deformation of the model before and after removing CSS was 0.99 mm and 1.10 mm, respectively, indicating an increase of 12%. The total deformation of the model before and after removing FNS was 0.65 mm and 0.76 mm, respectively, indicating an increase of 17%. The equivalent stress for CSS and FNS were 55.21 MPa and 250.67 MPa, respectively. The average equivalent stress on the cross-section of the femoral neck before and after removal of CSS was 7.76 MPa and 6.11 MPa, respectively. The average equivalent stress on the cross-section of the femoral neck before and after removal of FNS was 9.89 MPa and 8.79 MPa, respectively.Conclusions The retention of internal fixation may contribute to improved stability of the proximal femur. However, there still existed risks of stress concentration in internal fixation and stress shielding in the proximal femur. Compared to CSS, the removal of FNS results in larger bone tunnels and insufficient model stability. Further clinical interventions are recommended to address this issue.
引用
收藏
页数:8
相关论文
共 41 条
  • [21] Proximal femoral bionic nail-a novel internal fixation system for the treatment of femoral neck fractures: a finite element analysis
    Ding, Kai
    Zhu, Yanbin
    Zhang, Yifan
    Li, Yonglong
    Wang, Haicheng
    Li, Jiaxing
    Chen, Wei
    Zhang, Qi
    Zhang, Yingze
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
  • [22] Comparison of femoral mechanics before and after internal fixation removal and the effect of sclerosis on femoral stress: a finite element analysis
    Liu, Yang
    Song, Wenjie
    Liang, Haoran
    Li, Chaoxin
    Niu, Wenjie
    Shao, Huifeng
    Wang, Yuze
    Yang, Ziquan
    Li, Pengcui
    Wu, Xiaogang
    He, Yong
    Wei, Xiaochun
    Duan, Wangping
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [23] Comparison of femoral mechanics before and after internal fixation removal and the effect of sclerosis on femoral stress: a finite element analysis
    Yang Liu
    Wenjie Song
    Haoran Liang
    Chaoxin Li
    Wenjie Niu
    Huifeng Shao
    Yuze Wang
    Ziquan Yang
    Pengcui Li
    Xiaogang Wu
    Yong He
    Xiaochun Wei
    Wangping Duan
    BMC Musculoskeletal Disorders, 23
  • [24] Biomechanical Evaluation of the Femoral Neck System in Unstable Pauwels III Femoral Neck Fractures: A Comparison with the Dynamic Hip Screw and Cannulated Screws
    Stoffel, Karl
    Zderic, Ivan
    Gras, Florian
    Sommer, Christoph
    Eberli, Ursula
    Mueller, David
    Oswald, Martin
    Gueorguiev, Boyko
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2017, 31 (03) : 131 - 137
  • [25] Neck of femur fractures treated with the femoral neck system: outcomes of one hundred and two patients and literature review
    Davidson, Amit
    Blum, Shlomo
    Harats, Elad
    Kachko, Erick
    Essa, Ahmad
    Efraty, Ram
    Peyser, Amos
    Giannoudis, Peter, V
    INTERNATIONAL ORTHOPAEDICS, 2022, 46 (09) : 2105 - 2115
  • [26] Neck of femur fractures treated with the femoral neck system: outcomes of one hundred and two patients and literature review
    Amit Davidson
    Shlomo Blum
    Elad Harats
    Erick Kachko
    Ahmad Essa
    Ram Efraty
    Amos Peyser
    Peter V. Giannoudis
    International Orthopaedics, 2022, 46 : 2105 - 2115
  • [27] Low reoperation rate after fixation of displaced femoral neck fractures with the femoral neck system (FNS)
    Obey, Mitchel R.
    Falgons, Christian G.
    Eastman, Jonathan G.
    Choo, Andrew M.
    Achor, Timothy S.
    Munz, John W.
    Warner, Stephen J.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2024, 34 (05): : 2581 - 2588
  • [28] Biomechanical comparison of the femoral neck system versus InterTan nail and three cannulated screws for unstable Pauwels type III femoral neck fracture
    Wang, Zheng
    Yang, Yong
    Feng, Gangning
    Guo, Haohui
    Chen, Zhirong
    Chen, Yaogeng
    Jin, Qunhua
    BIOMEDICAL ENGINEERING ONLINE, 2022, 21 (01)
  • [29] Biomechanical comparison of the femoral neck system versus InterTan nail and three cannulated screws for unstable Pauwels type III femoral neck fracture
    Zheng Wang
    Yong Yang
    Gangning Feng
    Haohui Guo
    Zhirong Chen
    Yaogeng Chen
    Qunhua Jin
    BioMedical Engineering OnLine, 21
  • [30] Finite element study of the proximal femur with retained trochanteric gamma nail and after removal of nail
    Mahaisavariya, B.
    Sitthiseripratip, K.
    Suwanprateeb, J.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2006, 37 (08): : 778 - 785