A glassy carbon electrode modified with a nanocomposite consisting of MoS2 and reduced graphene oxide for electrochemical simultaneous determination of ascorbic acid, dopamine, and uric acid

被引:0
|
作者
Liwen Xing
Zhanfang Ma
机构
[1] Capital Normal University,Department of Chemistry
来源
Microchimica Acta | 2016年 / 183卷
关键词
MoS; Cyclic voltammetry; Differential pulse voltammetry; High-resolution transmission electron microscopy; FTIR; Electrochemical sensor;
D O I
暂无
中图分类号
学科分类号
摘要
We describe the synthesis of a hybrid nanocomposite consisting of MoS2 and reduced graphene oxide (MoS2/rGO) by a one-pot hydrothermal process, and the use of the material in an amperometric sensor. Scanning electron microscopy and nitrogen adsorption-desorption tests revealed that the nanocomposite possesses a porous and flower-like structure and a large specific surface. Cyclic voltammetry and differential pulse voltammetry demonstrated the nanocomposite to perform excellently in the electrochemical oxidation of ascorbic acid (AA), dopamine (DA), and uric acid (UA), respectively. The oxidation potentials are well separated (oxidation peaks at −64, 168 and 320 mV vs. Ag/AgCl) for AA, DA, and UA, and the respective detection sensitivities are strongly enhanced (0.12, 4.11 and 1.59 μA μM−1 cm−2). The sensor was applied to the detection of the three species in spiked human serum samples where it gave recoveries ranging from 98.9 to 104.1 % (for n = 3).
引用
收藏
页码:257 / 263
页数:6
相关论文
共 50 条
  • [41] Superlattice stacking by hybridizing layered double hydroxide nanosheets with layers of reduced graphene oxide for electrochemical simultaneous determination of dopamine, uric acid and ascorbic acid
    Asif, Muhammad
    Aziz, Ayesha
    Wang, Haitao
    Wang, Zhengyun
    Wang, Wei
    Ajmal, Muhammad
    Xiao, Fei
    Chen, Xuedong
    Liu, Hongfang
    MICROCHIMICA ACTA, 2019, 186 (02)
  • [42] Electrochemical sensor for simultaneous determination of ascorbic acid, uric acid and folic acid based on Mn-SnO2 nanoparticles modified glassy carbon electrode
    Lavanya, N.
    Fazio, E.
    Neri, F.
    Bonavita, A.
    Leonardi, S. G.
    Neri, G.
    Sekar, C.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 770 : 23 - 32
  • [43] Superlattice stacking by hybridizing layered double hydroxide nanosheets with layers of reduced graphene oxide for electrochemical simultaneous determination of dopamine, uric acid and ascorbic acid
    Muhammad Asif
    Ayesha Aziz
    Haitao Wang
    Zhengyun Wang
    Wei Wang
    Muhammad Ajmal
    Fei Xiao
    Xuedong Chen
    Hongfang Liu
    Microchimica Acta, 2019, 186
  • [44] An electrochemical sensor based on reduced graphene oxide/β-cyclodextrin/multiwall carbon nanotubes/polyoxometalate tetracomponent hybrid: Simultaneous determination of ascorbic acid, dopamine and uric acid
    Ma, Chaonan
    Xu, Pingping
    Chen, Hongzhong
    Cui, Jing
    Guo, Minjie
    Zhao, Jin
    MICROCHEMICAL JOURNAL, 2022, 180
  • [45] Electrocatalytic oxidation and simultaneous determination of uric acid and ascorbic acid on the gold nanoparticles-modified glassy carbon electrode
    Hu, Guangzhi
    Ma, Yonggen
    Guo, Yong
    Shao, Shijun
    ELECTROCHIMICA ACTA, 2008, 53 (22) : 6610 - 6615
  • [46] A Silver Hexacyanoferrate-Graphene Modified Glassy Carbon Electrode in Electrochemical Sensing of Uric Acid and Dopamine
    Zhang, Fenghua
    Li, Sue
    Zhang, Hua
    Li, Huaixiang
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (12): : 11181 - 11194
  • [47] A Voltammetric Sensor Based on Chemically Reduced Graphene Oxide-Modified Screen-Printed Carbon Electrode for the Simultaneous Analysis of Uric Acid, Ascorbic Acid and Dopamine
    Kanyong, Prosper
    Rawlinson, Sean
    Davis, James
    CHEMOSENSORS, 2016, 4 (04):
  • [48] Differential Pulse Voltammetric Determination of Folic Acid in the Presence of Ascorbic Acid using A Glassy Carbon Electrode Modified with Reduced Graphene Oxide
    Abd-Elsabour, Mohamed
    Toghan, Arafat
    Abo-bakr, Ahmed M.
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2022, 14 (08): : 789 - 805
  • [49] Simultaneous Voltammetric Determination of Norepinephrine, Ascorbic Acid and Uric Acid by TTAB Modified Carbon Paste Electrode
    Shankar, S. Sharath
    Swamy, Bahaddurghatta E. Kumara
    Mahanthesha, Kurangalara R.
    Vishwanatha, Chandrashekar C.
    Kumar, Mohan
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2013, 5 (05): : 555 - 573
  • [50] Study on Electrochemical Behaviors and Determination of Xanthine and Uric Acid on Modified Glassy Carbon Electrode
    Sun Kai
    Sun Deng-Ming
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2014, 42 (07) : 991 - 996