Influence of laminate direction and glue area on in-plane shear modulus of cross-laminated timber

被引:0
作者
Jonas Turesson
Zahra Sharifi
Sven Berg
Mats Ekevad
机构
[1] Luleå University of Technology,Department of Engineering Sciences and Mathematics, Division of Wood Science and Engineering, Skellefteå Campus
来源
SN Applied Sciences | 2020年 / 2卷
关键词
Cross-laminated timber; Diagonal compression test; Laminate direction; Shear modulus; Finite elements; Glue;
D O I
暂无
中图分类号
学科分类号
摘要
The use of cross-laminated timber (CLT) in constructing tall buildings has increased. So, it has become crucial to get a higher in-plane stiffness in CLT panels. One way of increasing the shear modulus, G, for CLT panels can be by alternating the layers to other angles than the traditional 0° and 90°. The diagonal compression test can be used to measure the shear stiffness from which G is calculated. A general equation for calculating the G value for the CLT panels tested in the diagonal compression test was established and verified by tests, finite element simulations and external data. The equation was created from finite element simulations of full-scale CLT walls. By this equation, the influence on the G value was a factor of 2.8 and 2.0 by alternating the main laminate direction of the mid layer from the traditional 90° to 45° and 30°, respectively. From practical tests, these increases were measured to 2.9 and 1.8, respectively. Another influence on the G value was studied by the reduction of the glue area between the layers. It was shown that the pattern of the contact area was more important than the size of the contact area.
引用
收藏
相关论文
共 31 条
[1]  
Lukacs I(2019)Strength and stiffness of cross-laminated timber (CLT) shear walls: State-of-the-art of analytical approaches Eng Struct 178 136-147
[2]  
Björnfot A(2016)Cross laminated timber (CLT) overview and development Eur J Wood Wood Prod 74 331-351
[3]  
Tomasi R(2016)Comparison of multi-storey cross-laminated timber and timber frame buildings by in situ modal analysis Constr Build Mater 102 1009-1017
[4]  
Brandner R(2019)Impact of board width on in-plane shear stiffness of cross-laminated timber Eng Struct 196 109249-5572
[5]  
Flatscher G(2019)In-plane shear modulus of cross-laminated timber by diagonal compression test Bioresour 14 5559-327
[6]  
Ringhofer A(2019)Picture frame and diagonal compression testing of cross-laminated timber Mater Struct 52 66-316
[7]  
Schickhofer G(2017)Cross laminated timber (CLT) diaphragms under shear: test configuration, properties and design Constr Build Mater 147 312-undefined
[8]  
Thiel A(2013)Einfaches Prufverfahren zur Bewertung der Schubfestigkeit von Kreuzlagenholz/Brettsperrholz Bautech 90 314-undefined
[9]  
Reynolds T(2015)ASTM E519/E519M-15 Standard test method for diagonal tension (shear) in masonry assemblages ASTM International, West Conshohocken, PA undefined undefined-undefined
[10]  
Casagrande D(undefined)undefined undefined undefined undefined-undefined