Characteristics and prognosis of interval cancers after biennial screen-film or full-field digital screening mammography

被引:0
|
作者
Roy J. P. Weber
Rob M. G. van Bommel
Marieke W. Louwman
Joost Nederend
Adri C. Voogd
Frits H. Jansen
Vivianne C. G. Tjan-Heijnen
Lucien E. M. Duijm
机构
[1] Catharina Hospital,Department of Radiology
[2] Netherlands Comprehensive Cancer Organization (IKNL),Department of Research
[3] Maastricht University,Department of Epidemiology
[4] Maastricht University Medical Centre,Department of Internal Medicine, Division of Medical Oncology
[5] Canisius-Wilhelmina Hospital,Department of Radiology
[6] Dutch Reference Centre for Screening,undefined
来源
关键词
Breast cancer; Screening mammography; Interval cancer; Digital mammography and survival rates;
D O I
暂无
中图分类号
学科分类号
摘要
We determined the characteristics and prognosis of interval breast cancers (IC) at screen-film (SFM) and full-field digital (FFDM) screening mammography. The study population consisted of 417,746 consecutive screening mammograms (302,699 SFM screens and 115,047 FFDM screens), obtained between 2000 and 2011. During 2-year follow-up, we collected breast imaging reports, surgical reports, and pathology results. A total of 800 ICs had been diagnosed in the screened population, of which 288 detected in the first year (early ICs) and 512 in the second year (late ICs) after a negative screen. 31.3 % of early IC’s and 19.1 % of late IC’s, respectively, were visible in retrospect on the latest previous screens, but had been missed during screening (P < 0.001). Missed invasive ICs were larger (28.5 mm vs. 23.9 mm, P = 0.003) and showed a higher fraction of T3+cancers (16.9 vs. 8.5 %, P = 0.02) than true ICs (i.e., not visible at the latest screen). A higher portion of missed than true ICs underwent mastectomy (44.7 vs. 30.8 %, P = 0.002). We found no differences in mammographic and tumor characteristics for early ICs, detected either after SFM or FFDM. Late ICs following FFDM were more often true ICs than missed ICs (69.0 vs. 57.6 %, P = 0.03) and more often receptor triple negative (P = 0.02), compared to late ICs at SFM. Interval cancer subgroups showed comparable overall survival. Interval cancer subgroups show distinctive mammographic and tumor characteristics but a comparable overall survival.
引用
收藏
页码:471 / 483
页数:12
相关论文
共 50 条
  • [41] Comparison of full-field digital mammography with screen-film mammography for cancer detection: Results of 4,945 paired examinations
    Lewin, JM
    Hendrick, RE
    D'Orsi, CJ
    Isaacs, PK
    Moss, LJ
    Karellas, A
    Sisney, GA
    Kuni, CC
    Cutter, GR
    RADIOLOGY, 2001, 218 (03) : 873 - 880
  • [42] Comparison of full-field digital mammography to screen-film mammography with respect to contrast and spatial resolution in tissue equivalent breast phantoms
    Kuzmiak, CM
    Pisano, ED
    Cole, EB
    Zeng, DL
    Burns, CB
    Roberto, C
    Pavic, D
    Lee, Y
    Seo, BK
    Koomen, M
    Washburn, D
    MEDICAL PHYSICS, 2005, 32 (10) : 3144 - 3150
  • [43] Full-Field Digital versus Screen-Film Mammography: Comparison within the UK Breast Screening Program and Systematic Review of Published Data
    Vinnicombe, Sarah
    Pinto Pereira, Snehal M.
    McCormack, Valerie A.
    Shiel, Susan
    Perry, Nick
    Silva, Isabel M. dos Santos
    RADIOLOGY, 2009, 251 (02) : 347 - 358
  • [44] Computer-aided detection of masses in full-field digital mammography using screen-film mammograms for training
    Kallenberg, Michiel
    Karssemeijer, Nico
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (23): : 6879 - 6891
  • [45] SCREEN-FILM VERSUS FULL-FIELD DIGITAL MAMMOGRAPHY: RADIATION DOSE AND IMAGE QUALITY IN A LARGE TEACHING HOSPITAL
    Stantic, Tomislav J.
    Ciraj-Bjelac, Olivera E.
    Stojanovic, Saida S.
    Basta-Nikolic, Marijana D.
    Arandjic, Danijela D.
    Stoiljkovic, Dragana S.
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2013, 28 (04): : 398 - 405
  • [46] Dose comparison between screen/film and full-field digital mammography
    Gennaro, Gisella
    di Maggio, Cosimo
    EUROPEAN RADIOLOGY, 2006, 16 (11) : 2559 - 2566
  • [47] Comparison of radiation dose using full field digital and conventional screen-film mammography in a screening clinic
    Gingold, E
    MEDICAL PHYSICS, 2005, 32 (06) : 2100 - 2100
  • [48] Dose comparison between screen/film and full-field digital mammography
    Gisella Gennaro
    Cosimo di Maggio
    European Radiology, 2006, 16 : 2559 - 2566
  • [49] Full-field digital mammography compared with screen-film mammography in the detection of breast cancer: rays of light through DMIST or more fog?
    Tice, Jeffrey A.
    Feldman, Mitchell D.
    BREAST CANCER RESEARCH AND TREATMENT, 2008, 107 (02) : 157 - 165
  • [50] Comparison of full-field digital mammography to screen-film mammography with respect to diagnostic accuracy of lesion characterization in breast tissue biopsy specimens
    Kuzmiak, CM
    Millnamow, GA
    Qaqish, B
    Pisano, ED
    Cole, EB
    Brown, ME
    ACADEMIC RADIOLOGY, 2002, 9 (12) : 1378 - 1382