Investigation on thermodynamic performance analysis and environmental effects of various new refrigerants used in air conditioners

被引:0
作者
Sharmas Vali Shaik
Saboor Shaik
Kirankumar Gorantla
Debasish Mahapatra
Ashok BabuTalanki Puttaranga Setty
机构
[1] National Institute of Technology Karnataka,Department of Mechanical Engineering
[2] Vellore Institute of Technology,School of Mechanical Engineering
[3] Sasi Institute of Technology & Engineering,Department of Mechanical Engineering
来源
Environmental Science and Pollution Research | 2020年 / 27卷
关键词
Air conditioners; CO; emissions; EER; GWP; R22 alternatives; TEWI;
D O I
暂无
中图分类号
学科分类号
摘要
The main aim of this present investigation is to evaluate performance and environmental impact analysis of various novel mixture refrigerants as R22 replacements theoretically. Refrigerants with lower global warming potential (GWP) can be adequate for bringing down emissions which are concerned for air conditioners. In this investigation, twenty-seven refrigerants were developed at several compositions. Important studies such as computation of CO2 emissions using total equivalent warming impact (TEWI), toxicity and flammability analysis of various considered refrigerants were also carried out in this investigation. Performance analysis of refrigerants was conducted under different operating conditions. Results showed that the energy efficiency ratios (EERs) of refrigerants such as R1270, RM30 (R152a/R1270/RE170 of 25/71/4 by mass percentage) and RM50 (R152a/R1270/RE170 of 10/85/5 by mass percentage) were closer to that of R22 and they are relatively lower than R22 by 0.95%, 1.34% and 1.80%, respectively. Toxicity investigation exhibited that all the refrigerants studied were classified into nontoxic category (A) whereas flammability investigation revealed that all the novel refrigerant mixtures (RM10 to RM50) were classified into flammable category (A3). CO2 emissions (TEWI) released from air conditioner working with R1270, RM30 and RM50 were 7.41%, 6.85% and 6.51%, respectively, lower than that of R22. In terms of several thermodynamic aspects, the performance of refrigerants such as R1270, RM30 and RM50 were superior to those of R22 and its various considered alternatives working under different operating conditions, although their EERs are fairly lower than R22 and hence, these refrigerants could be considered suitable environment-friendly alternatives to R22 used in air conditioners. The present study gives essential information and a road map towards the development of low GWP R22 alternative refrigerant blends from the viewpoint of toxicity, flammability, performance aspects, environmental and safety aspects, respectively.
引用
收藏
页码:41415 / 41436
页数:21
相关论文
共 95 条
[1]  
Ahamed JU(2014)Investigation of environmental and heat transfer analysis of air conditioner using hydrocarbon mixture compared to R22 Arab J Sci Eng 39 4141-4150
[2]  
Saidur R(2019)Thermodynamic analysis of various refrigerants for automotive air conditioning system Arab J Sci Eng 44 1697-1707
[3]  
Masjuki HH(2018)A study on the use of propane (R-290) in vending machines as a substitute for R-134a to minimise the global warming potential Int J Glob Warm 4 131-141
[4]  
Aized T(2016)Experimental investigation on the performance and global environmental impact of a refrigeration system retrofitted with alternative refrigerants Int J Refrigeration 70 119-127
[5]  
Hamza A(2004)An evaluation of R22 substitutes performances regulating continuously the compressor refrigeration capacity Appl Therm Eng 24 127-139
[6]  
Alkhaledi KA(2008)Theoretical analysis of a vapour compression refrigeration system with R502, R404A and R507A Int J Refrigeration 31 998-1005
[7]  
Means K(2009)Thermodynamic analysis of R422 series refrigerants as alternative refrigerants to HCFC22 in a vapour compression refrigeration system Int J Energy Res 33 753-765
[8]  
Antunes AHP(2007)Exergy analysis of a vapour compression refrigeration system with R-22, R-407C and R-410A Int J Exergy 4 441-454
[9]  
Bandarra Filho EP(2011)Performance investigation of ozone-friendly R404A and R507 refrigerants as alternatives to R22 in a window air conditioner Energy Build 43 3139-3143
[10]  