Baroreflex failure and beat-to-beat blood pressure variation

被引:0
作者
Takuya Kishi
机构
[1] Kyushu University,Department of Advanced Risk Stratification for Cardiovascular Diseases, Center for Disruptive Cardiovascular Medicine
来源
Hypertension Research | 2018年 / 41卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Hypertension has strong adverse effects on cardiovascular diseases, and increased blood pressure (BP) variability (BPV) is closely associated with the development of hypertensive organ injuries and the occurrence of cardiovascular diseases. Similar to other forms of BPV, short-term beat-to-beat BPV has also been established as a risk factor for cardiovascular diseases. Baroreflex failure is the major mechanism involved in the pathophysiology of short-term beat-to-beat BPV. Previous clinical and animal studies have demonstrated that baroreflex failure disrupted beat-to-beat BPV and hypertensive organ damage. Moreover, short-term beat-to-beat BPV was an independent determinant of vascular elasticity. Although, the clinical measurement tools and therapeutics for beat-to-beat BPV are not sufficient, we should consider that large beat-to-beat BPV is an important risk factor for cardiovascular diseases in patients with hypertension.
引用
收藏
页码:547 / 552
页数:5
相关论文
共 50 条
[21]   Cuffless Beat-to-Beat Blood Pressure Estimation from Photoplethysmogram Signals [J].
Wuerich, Carolin ;
Wiede, Christian ;
Schiele, Gregor .
2023 IEEE 36TH INTERNATIONAL SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS, CBMS, 2023, :305-310
[22]   Beat-to-beat blood pressure and heart rate responses to the Valsalva maneuver [J].
David S. Goldstein ;
William P. Cheshire .
Clinical Autonomic Research, 2017, 27 :361-367
[23]   Finger beat-to-beat blood pressure responses to successive hand elevations [J].
Raamat, R. ;
Jagomagi, K. ;
Talts, J. ;
Mager, I. .
MEDICAL ENGINEERING & PHYSICS, 2009, 31 (05) :522-527
[24]   BEAT-TO-BEAT BLOOD-PRESSURE RESPONSE IN ASYMPTOMATIC IDDM SUBJECTS [J].
GOLDSTEIN, IB ;
NALIBOFF, BD ;
SHAPIRO, D ;
FRANK, HJL .
DIABETES CARE, 1988, 11 (10) :774-779
[25]   Effect of peripheral vasoconstriction on the beat-to-beat measurement of finger blood pressure [J].
Raamat, R ;
Talts, J ;
Jagomägi, K ;
Kingisepp, PH .
PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 :2223-2226
[26]   Reduced resting beat-to-beat blood pressure variability in multiple sclerosis [J].
Trotter, Claire ;
Young, Ben ;
Huang, Mu ;
Allen, Dustin ;
Fade, Paul ;
Davis, Scott .
FASEB JOURNAL, 2021, 35
[27]   Beat-to-beat blood pressure and heart rate responses to the Valsalva maneuver [J].
Goldstein, David S. ;
Cheshire, William P., Jr. .
CLINICAL AUTONOMIC RESEARCH, 2017, 27 (06) :361-367
[28]   ADOPTION OF CONTINUOUS BEAT-TO-BEAT NOCTURNAL BLOOD PRESSURE MEASUREMENT IN AMBULATORY BLOOD PRESSURE MONITORING [J].
Estrada, Sebastian ;
Kwon, Younghoon ;
Baruch, Martin ;
Harrison, Elizabeth ;
Williams, Ronald ;
Cho, Yeilim ;
Gerdt, David ;
Bonner, Heather ;
Mazimba, Sula ;
Berry, Richard .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (09) :1893-1893
[29]   Beat-to-Beat Blood Pressure Variations While Standing are Associated with Postural Changes in Blood Pressure [J].
Goh, C. H. ;
Ng, S. C. ;
Tan, M. P. .
INTERNATIONAL CONFERENCE FOR INNOVATION IN BIOMEDICAL ENGINEERING AND LIFE SCIENCES, ICIBEL2015, 2016, 56 :44-48
[30]   Blood pressure measurements in research: suitability of auscultatory, beat-to-beat, and ambulatory blood pressure measurements [J].
Carlson, Debra J. ;
Dieberg, Gudrun ;
Mcfarlane, James R. ;
Smart, Neil A. .
BLOOD PRESSURE MONITORING, 2019, 24 (01) :18-23