Numerical Study of the Effect of Different Transverse Fire Locations on Smoke Mass Flow Rate in Tunnel Fires

被引:0
作者
Rongfang Chen
Zhiguo Guo
Yangpeng Liu
Yurun Yang
Qinglan Tan
机构
[1] Jiangxi University of Science and Technology,School of Emergency Management and Safety Engineering
[2] Zhejiang University,State Key Laboratory of Clean Energy Utilization
[3] Huzhou Institute of Zhejiang University,undefined
来源
Fire Technology | 2023年 / 59卷
关键词
Tunnel fires; Transverse fire locations; Mass flow rate; Smoke transport characteristics; Fire dynamics simulator;
D O I
暂无
中图分类号
学科分类号
摘要
Wall restriction is an important factor affecting flame space development, air entrainment and heat transfer. To investigate the smoke characteristics in the one-dimensional horizontal spreading stage at different transverse fire locations in tunnel, FDS was used to simulate and analyze the smoke mass flow rate. The results show that the average smoke mass flow rate is positively correlated with distance from fire source to sidewall and heat release rate (HRR). The maximum smoke temperature rises decay exponentially along the longitudinal direction of the tunnel. Based on dimensional analysis, a prediction model is proposed to predict the average smoke mass flow rate in one-dimensional horizontal spreading stage in tunnel. For wall fires, predicted mass flow rate is 1.29 times of Zukoski model via generalizing the "mirror" effect. For non-wall fires, the dimensionless smoke mass flow is proportional to the 0.19 power of the dimensionless HRR. Besides, the reliability of the prediction model is verified by comparing with full-scale and reduced-scale experiments.
引用
收藏
页码:2567 / 2586
页数:19
相关论文
共 234 条
[1]  
Li HH(2020)Phenomenological characteristics of continuous spill fires in a tunnel with longitudinal ventilation Process Saf Environ 138 108-116
[2]  
Liu JH(2002)Toxicity of fire smoke Crit Rev Toxicol 32 259-289
[3]  
Ge JW(2017)Analysis of fire deaths in Poland and influence of smoke toxicity Forensic Sci Int 277 77-87
[4]  
Alarie Y(2022)Numerical study of the characteristics of smoke spread in tunnel fires during construction and method for improvement of smoke control Case Stud Therm Eng 34 181-195
[5]  
Giebultowicz J(2021)Lessons learned from critical accidental fires in tunnels Tunn Undergr Space Technol 113 134-142
[6]  
Ruzycka M(1972)Calculation of response time of ceiling-mounted fire detectors Fire Technol 8 889-905
[7]  
Wroczynski P(2018)Experimental and numerical studies on ceiling maximum smoke temperature and longitudinal decay in a horseshoe shaped tunnel fire Case Stud Therm Eng 12 2839-2858
[8]  
Purser DA(2014)Position of maximum ceiling temperature in a tunnel fire Fire Technol 50 61-68
[9]  
Stec AA(2021)Investigation on the tunnel curvature effect upon the ceiling temperature of tunnel fires: a numerical simulation Fire Technol 57 2143-2166
[10]  
Yao YZ(2016)Numerical analysis of smoke dispersion against the wind in a tunnel fire J Wind Eng Ind Aerodyn 158 1765-1793