Technical limitations and pitfalls of diffusion-weighted imaging in intraoperative high-field MRI

被引:0
作者
Constantin Roder
Patrick Haas
Marcos Tatagiba
Ulrike Ernemann
Benjamin Bender
机构
[1] University Hospital Tübingen,Department of Neurosurgery
[2] Eberhard Karls University,Department of Neuroradiology
[3] Eberhard Karls University,undefined
来源
Neurosurgical Review | 2021年 / 44卷
关键词
Intraoperative MRI; Diffusion-weighted imaging; Neurosurgery;
D O I
暂无
中图分类号
学科分类号
摘要
Objective: Image quality in high-field intraoperative MRI (iMRI) is often influenced negatively by susceptibility artifacts. While routine sequences are rather robust, advanced imaging such as diffusion-weighted imaging (DWI) is very sensitive to susceptibility resulting in insufficient imaging data. This study aims to analyze intraoperatively acquired DWI to identify the main factors for susceptibility, to compare results with postoperative images and to identify technical aspects for improvement of intraoperative DWI.
引用
收藏
页码:327 / 334
页数:7
相关论文
共 75 条
  • [1] Roder C(2016)Beneficial impact of high-field intraoperative magnetic resonance imaging on the efficacy of pediatric low-grade glioma surgery Neurosurg Focus 40 297-304
  • [2] Breitkopf M(2014)Maximizing the extent of resection and survival benefit of patients in glioblastoma surgery: High-field iMRI versus conventional and 5-ALA-assisted surgery Eur J Surg Oncol 40 533-546
  • [3] Bisdas S(2018)Fluorescence guided surgery by 5-ALA and intraoperative MRI in high grade glioma: a systematic review J Neuro-Oncol 141 911-919
  • [4] Freitas RS(2012)Intraoperative visualization of fiber tracking based reconstruction of language pathways in glioma surgery Neurosurgery 70 ons151-ons158
  • [5] Dimostheni A(2013)Intraoperative visualization of residual tumor: the role of perfusion-weighted imaging in a high-field intraoperative magnetic resonance scanner Neurosurgery 72 551-559
  • [6] Ebinger M(2013)Spectroscopy imaging in intraoperative MR suite: tissue characterization and optimization of tumor resection Int J Comput Assist Radiol Surg 9 269-277
  • [7] Wolff M(2011)Intraoperative acquisition of fMRI and DTI Neurosurg Clin N Am 22 428-438
  • [8] Tatagiba M(2005)Serial diffusion-weighted magnetic resonance imaging in cases of glioma: distinguishing tumor recurrence from postresection injury J Neurosurg 103 191-197
  • [9] Schuhmann MU(2016)The value of intraoperative and early postoperative magnetic resonance imaging in low-grade glioma surgery: a retrospective study World Neurosurg 93 756-765
  • [10] Roder C(2019)The Zurich checklist for safety in the intraoperative magnetic resonance imaging suite: technical note Oper Neurosurg (Hagerstown) 16 328-330