Based on a new electrogenerated chemiluminescence (ECL) analytical idea, this paper explains a sensitive and selective flow-injection ECL method using luminol for the determination of isoniazid, based on the sensitizing effect of isoniazid for the weak ECL emission of electrochemically oxidized luminol. Under the optimum experimental conditions, the relative ECL intensity was linear with isoniazid concentration in the range of 4.0 × 10–8 mol/L to 8.0 × 10–6 mol/L and with a detecting limit of 2.8 × 10–8 mol/L.
引用
收藏
页码:1095 / 1099
页数:4
相关论文
共 50 条
  • [31] A Novel Enhancing Flow-Injection Chemiluminescence Method for the Determination of Glutathione Using the Reaction of Luminol with Hydrogen Peroxide
    Lun Wang
    Yongxin Li
    Danhua Zhao
    Changqin Zhu
    Microchimica Acta, 2003, 141 : 41 - 45
  • [32] Determination of norfloxacin by flow injection electrogenerated chemiluminescence
    Ma, HY
    Zheng, XW
    Zhang, ZJ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2004, 32 (07) : 857 - 860
  • [33] Determination of phloroglucinol by flow injection electrogenerated chemiluminescence
    Guo, ZH
    Zheng, XW
    Zhang, ZJ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2002, 30 (04) : 461 - 463
  • [34] DETERMINATION OF SULFITE IN WINE THROUGH FLOW-INJECTION ANALYSIS BASED ON THE SUPPRESSION OF LUMINOL CHEMILUMINESCENCE
    HUANG, YL
    KIM, JM
    SCHMID, RD
    ANALYTICA CHIMICA ACTA, 1992, 266 (02) : 317 - 323
  • [35] Flow-Injection Determination of Ornidazole by Chemiluminescence Detection Basedon a Luminol-Ferricyanide Reaction
    Yi Lv
    Zhujun Zhang
    Deyong He
    Yufei Hu
    Analytical Sciences, 2003, 19 : 625 - 626
  • [36] Flow-injection inhibition chemiluminescence determination of indapamide based on luminol-ferricyanide reaction
    Wang, ZP
    Zhang, ZJ
    Zhang, XO
    Fu, ZF
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 35 (01) : 1 - 7
  • [37] Development of a luminol-based chemiluminescence flow-injection method for the determination of dichlorvos pesticide
    Wang, JN
    Zhang, C
    Wang, HX
    Yang, FZ
    Zhang, XR
    TALANTA, 2001, 54 (06) : 1185 - 1193
  • [38] Flow injection determination of isoniazid using N-bromosuccinimide- and N-chlorosuccinimide-luminol chemiluminescence systems
    Safavi, A
    Karimi, MA
    Nezhad, MRH
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 30 (05) : 1499 - 1506
  • [39] Flow-injection determination of cysteine in pharmaceuticals based on luminol-persulphate chemiluminescence detection
    Waseem, Amir
    Yaqoob, Mohammad
    Nabi, Abdul
    LUMINESCENCE, 2008, 23 (03) : 144 - 149
  • [40] Flow-injection determination of ornidazole by chemiluminescence detection based on a luminol-ferricyanide reaction
    Lv, Y
    Zhang, ZJ
    He, DY
    Hu, YF
    ANALYTICAL SCIENCES, 2003, 19 (04) : 625 - 627