Numerical and Experimental Investigations of Different Cross-Sectional Configuration of Plain Concrete and CFST Short Columns Under Axial Compression

被引:0
作者
Palash Dey
R. K. Gupta
A. I. Laskar
机构
[1] National Institute of Technology Silchar,Department of Civil Engineering
来源
International Journal of Civil Engineering | 2019年 / 17卷
关键词
Concrete filled steel tube; Short column; Axial compression; Energy absorption capacity; Failure mode;
D O I
暂无
中图分类号
学科分类号
摘要
In the present study, the finite-element (FE) and experimental analysis were carried out to understand the behaviour of the different cross-sectional configuration of plain concrete and concrete filled steel tube (CFST) short columns. A numerical model for the simulation of columns subjected to axial compression has been established using the commercial software package ABAQUS. The ultimate load carrying capacities of the different configuration of short columns are calculated using ACI-318 code. The results estimated according to the design code are found in good agreement with the FE and measured results. It has been noticed that the ductility of the CFST column is significantly high compared to the concrete alone. The outcome of the study reveals that the circular column profiles are good geometry to be considered, since they have outstanding performance concerning of energy absorption in axial loading condition. Furthermore, it has been noticed that the numerical model shows the satisfactory performance in predicting the failure modes. At the end of the study, it is recommended that the utilization of various grade of concrete layer combination of CFST columns shows a better choice from the economic point of view.
引用
收藏
页码:1585 / 1601
页数:16
相关论文
共 89 条
[1]  
Schneider SP(1998)Axially loaded concrete-filled steel tubes J Struct Eng 124 1125-1138
[2]  
Zhong Shan-tong(1998)Application and development of concrete-filled steel tubes (CFST) in high rise buildings Adv Struct Eng 2 149-159
[3]  
Zhang Sumei(2000)Strength of concrete filled steel box columns incorporating local buckling J Struct Eng 126 341-352
[4]  
Uy B(2002)Behavior of fiber reinforced concrete-filled tubular columns in compression Mater struct 35 332-337
[5]  
Campione G(2002)Experimental behavior of high strength square concrete-filled steel tube beam-columns J Struct Eng 128 309-318
[6]  
La Mendola L(2003)Ultimate capacity of high-strength rectangular concrete-filled steel hollow section stub columns J Constr Steel Res 59 1499-1515
[7]  
Sanpaolesi L(2004)Concrete-filled double skin (SHS outer and CHS inner) steel tubular beam-columns Thin Walled Struct 42 1329-1355
[8]  
Scibilia N(2004)Behavior of centrally loaded concrete-filled steel tube short columns J Struct Eng 130 180-188
[9]  
Zingone G(2008)Behaviour of concrete-filled steel tubular stub columns subjected to axially local compression J Constr Steel Res 64 377-387
[10]  
Varma AH(2008)Behavior of thin walled steel tube confined concrete stub columns subjected to axial local compression Thin Walled Struct 46 155-164