Early failure with the Journey-Deuce bicompartmental knee arthroplasty

被引:10
作者
Dudhniwala A.G. [1 ]
Rath N.K. [1 ]
Joshy S. [2 ]
Forster M.C. [1 ]
White S.P. [1 ]
机构
[1] Cardiff & Vale Orthopaedic Centre, University Hospital Llandough, Penlan Road, Penarth
[2] Hull and East Yorkshire Hospitals NHS Trust, Hull
关键词
Arthroplasty; Bicompartmental; Failure; Knee; Loosening; Replacement; Revision;
D O I
10.1007/s00590-016-1760-4
中图分类号
学科分类号
摘要
The aim of this study was to evaluate the early functional outcome and survivorship of a bicompartmental knee arthroplasty implant (Journey-Deuce) in a cohort of patients with combined medial and patellofemoral degenerative osteoarthritis. Fifteen patients with a mean age of 57 years were followed up prospectively and evaluated with clinical examination, Oxford knee score and radiology imaging. Poor pain scores, concerns about the tibial fixation, early aseptic loosening of the tibial component and a revision rate of 60 % at a minimum follow-up of 54 months are reported. Implantation of this prosthesis was stopped at our institution well before the first revision due to an unfavourable early clinical response. This was further endorsed by an unacceptable revision rate. The outcome of the Journey-Deuce bicompartmental knee replacement was considerably worse than the published outcome of total knee replacement. © 2016, Springer-Verlag France.
引用
收藏
页码:517 / 521
页数:4
相关论文
共 12 条
[1]  
Ledingham J., Regan M., Jones A., Doherty M., Radiographic patterns and associations of osteoarthritis of the knee in patients referred to hospital, Ann Rheum Dis, 52, pp. 520-526, (1993)
[2]  
Rolston L., Bresch J., Engh G., Franz A., Kreuzer S., Nadaud M., Puri L., Wood D., Bicompartmental knee arthroplasty: a bone-sparing, ligament-sparing, and minimally invasive alternative for active patients, Orthopedics, 30, pp. 70-73, (2007)
[3]  
Rolston L., Siewert K., Assessment of knee alignment after bicompartmental knee arthroplasty, J Arthroplast, 24, pp. 1111-1114, (2009)
[4]  
Wunschel M., Lo J., Dilger T., Wulker N., Muller O., Influence of bi- and tri-compartmental knee arthroplasty on the kinematics of the knee joint, BMC Musculoskelet Disord, 12, (2011)
[5]  
Morrison T.A., Nyce J.D., Macaulay W.B., Geller J.A., Early adverse results with bicompartmental knee arthroplasty: a prospective cohort comparison to total knee arthroplasty, J Arthroplast, 26, pp. 35-39, (2011)
[6]  
Muller M., Matziolos G., Falk R., Hommel H., The bicompartmental knee joint prosthesis Journey Deuce: failure analysis and optimization strategies, Orthopade, 41, pp. 894-904, (2012)
[7]  
Palumbo B.T., Henderson E.R., Edwards P.K., Burris R.B., Gutierrez S., Raterman S.J., Initial experience of the Journey-Deuce bicompartmental knee prosthesis: a review of 36 cases, J Arthroplast, 26, pp. 40-45, (2011)
[8]  
Kozinn S., Scott R., Unicondylar knee arthroplasty, J Bone Joint Surg Am, 71, pp. 145-150, (1989)
[9]  
Mercier N., Wimsey S., Saragaglia D., Long-term clinical results of the Oxford medial unicompartmental knee arthroplasty, Int Orthop, 34, pp. 1137-1143, (2010)
[10]  
Lundberg-Jensen A., Kourakis A.H., Rossen B., Kofoed H., Radiolucency adjacent to the tibial component in total knee arthroplasty, Orthopedics, 25, pp. 49-51, (2002)