Evaluation of optic nerve head changes with optic coherence tomography in patients with idiopathic intracranial hypertension

被引:0
|
作者
Yasemin Eren
Naciye Kabatas
Hayat Guven
Selcuk Comoglu
Canan Gurdal
机构
[1] Neurology Clinic of Diskapi Yildirim Beyazit Training and Research Hospital,
[2] Opthalmology Clinic of Diskapi Yildirim Beyazit Training and Research Hospital,undefined
来源
Acta Neurologica Belgica | 2019年 / 119卷
关键词
Idiopathic intracranial hypertension; OCT; RNLF; Disc area;
D O I
暂无
中图分类号
学科分类号
摘要
In the case of mild papilledema, fundoscopy findings may sometimes be insufficient, leading to false and misleading indices in the diagnosis of early-stage idiopathic intracranial hypertension (IIH). This study aims to evaluate these patients through optic coherence tomography (OCT). The study included 54 individuals diagnosed with IIH and 48 healthy individuals in the control group. All patients underwent neurological and ophthalmologic examinations. Opening pressure values of patients’ cerebrospinal fluid (CSF) were recorded. We measured the thickness of the retinal nerve fiber layer (RNFL) and the ganglion cell complex, cup volume, and the optical disc area, as well as the neuroretinal rim in both groups. A total of 108 eyes from the patient group and 96 eyes from the control group were evaluated. It was found that the mean value of the RNFL thickness of the IIH patients was greater than the control group in the following eight segments: superior nasal, superior temporal, inferior nasal, inferior temporal, nasal superior, nasal inferior, temporal superior, and temporal inferior (p < 0.01 for all). In contrast to the control group, the disc and rim area values of the patient group were higher (p < 0.01), while the cup volume was smaller (p < 0.01) than in the control group. In the patient group, a positive correlation was observed between the papilledema grade and the RNFL thickness (r = 0.64, p < 0.01), CSF opening pressure (r = 0.59, p < 0.01), disc area (r = 0.68, p < 0.01), and rim area (r = 0.70, p < 0.01). Furthermore, RNFL thickness, CSF opening pressure (r = 0.61, p < 0.01), disc area (r = 0.71, p < 0.01), and rim area (r = 0.71, p < 0.01) values were determined to be positively correlated to each other. OCT is believed to contribute to the diagnosis of IIH, by providing reliable data on optical cup volume, optical disc and rim area, and a greater RNFL thickness.
引用
收藏
页码:351 / 357
页数:6
相关论文
共 50 条
  • [1] Evaluation of optic nerve head changes with optic coherence tomography in patients with idiopathic intracranial hypertension
    Eren, Yasemin
    Kabatas, Naciye
    Guven, Hayat
    Comoglu, Selcuk
    Gurdal, Canan
    ACTA NEUROLOGICA BELGICA, 2019, 119 (03) : 351 - 357
  • [2] Optical coherence tomography of the optic nerve head before and after optic nerve sheath fenestration for idiopathic intracranial hypertension
    Magdy M. Shuaib
    Gehan M. Helmy
    Nashwa Badr Eldin
    Ayman G. Elnahry
    Gehad A. Elnahry
    Acta Neurologica Belgica, 2020, 120 : 775 - 777
  • [3] Optical coherence tomography of the optic nerve head before and after optic nerve sheath fenestration for idiopathic intracranial hypertension
    Shuaib, Magdy M.
    Helmy, Gehan M.
    Eldin, Nashwa Badr
    Elnahry, Ayman G.
    Elnahry, Gehad A.
    ACTA NEUROLOGICA BELGICA, 2020, 120 (03) : 775 - 777
  • [4] Optic Nerve Head Volumetry by Optical Coherence Tomography in Papilledema Related to Idiopathic Intracranial Hypertension
    Dreesbach, Michelle
    Joachimsen, Lutz
    Kuechlin, Sebastian
    Reich, Michael
    Gross, Nikolai J.
    Brandt, Alexander U.
    Schuchardt, Florian
    Harloff, Andreas
    Boehringer, Daniel
    Lagreze, Wolf A.
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2020, 9 (03):
  • [5] OCT measurements of optic nerve head changes in idiopathic intracranial hypertension
    Huang-Link, Yu-Min
    Al-Hawasi, Abbas
    Oberwahrenbrock, Timm
    Jin, Ya-Ping
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2015, 130 : 122 - 127
  • [6] Optic Nerve Head Changes Measured by Swept Source Optical Coherence Tomography and Angiography in Patients with Intracranial Hypertension
    Wang, Hang
    Cao, Le
    Kwapong, William Robert
    Liu, Guina
    Wang, Ruilin
    Liu, Junfeng
    Wu, Bo
    OPHTHALMOLOGY AND THERAPY, 2023, 12 (06) : 3295 - 3305
  • [7] Optic Nerve Head Changes Measured by Swept Source Optical Coherence Tomography and Angiography in Patients with Intracranial Hypertension
    Hang Wang
    Le Cao
    William Robert Kwapong
    Guina Liu
    Ruilin Wang
    Junfeng Liu
    Bo Wu
    Ophthalmology and Therapy, 2023, 12 (6) : 3295 - 3305
  • [8] Optic Nerve Evaluation in Idiopathic Intracranial Hypertension
    De Bernardo, M.
    Vitiello, L.
    Rosa, N.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2019, 40 (07) : E36 - E36
  • [9] Optic Nerve Ultrasound Evaluation in Idiopathic Intracranial Hypertension
    De Bernardo, Maddalena
    Vitiello, Livio
    De Pascale, Ilaria
    Capasso, Luigi
    Cornetta, Palmiro
    Rosa, Nicola
    FRONTIERS IN MEDICINE, 2022, 9
  • [10] Optic Nerve Evaluation in Idiopathic Intracranial Hypertension REPLY
    Kennedy, T. A.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2019, 40 (07) : E37 - E37