摘要
The current study aimed at examining surface and chemical composition changes of retrieved mini-implants after different periods of service as aids of anchorage for orthodontic patients. This study examined 72 retrieved orthodontic self-tapping and self-drilling mini-implants, 1.7 mm in diameter and 8 mm in length (OrthoEasy system, Forestadent, Pforzheim, Germany) from 36 adult orthodontic patients (18 men and 18 women, mean age = 23 years). The retrieved mini-implants were divided into 3 groups according to service period: 3–6 months (3M–6M) group, 6–12 months (6M–12M) group, and 12–24 months (12M–24M) group, with 24 mini-implants in each group. The control group (As Received) comprised of 24 unused mini-implants of the same type (AR group). All mini-implant heads and threaded bodies were examined for chemical characterization and topographical features by SEM–EDS. The average weight percentages for the following elements Ti, Al, and O2 were obtained and compared among the 4 groups. There was significant decrease in titanium content and deterioration for the surface properties for all parts of the mini-implants after being used inside patients’ oral cavities for more than 6 months p < 0.05. The period of mini-implant service inside patients’ oral cavities should not exceed 6 months.
引用
收藏
页码:208 / 214
页数:6
相关论文
共 122 条
[1]  
Vilani GN(2015)Influence of cortical thickness on the stability of mini-implants with microthreads Braz Oral Res 29 1-7
[2]  
Ruellas AC(2002)Orthodontic anchorage with specific fixtures: related study analysis Am J Orthod Dentofac Orthop 122 84-94
[3]  
Mattos CT(2005)Dental implants for orthodontic anchorage Am J Orthod Dentofac Orthop 127 713-722
[4]  
Fernandes DJ(2004)Severe anterior open-bite case treated using titanium screw anchorage Angle Orthod 74 558-567
[5]  
Elias CN(2003)Factors associated with the stability of titanium screws placed in the posterior region for orthodontic anchorage Am J Orthod Dentofac Orthop 124 373-378
[6]  
Favero L(2003)Intrusion of posterior teeth using mini-screw implants Am J Orthod Dentofac Orthop 123 690-694
[7]  
Brollo P(2014)Acceptance of orthodontic miniscrews as temporary anchorage devices Patient Preference Adherence 8 933-937
[8]  
Bressan E(2008)Clinical outcome of mini-screws used as orthodontic anchorage Clin Implant Dent Relat Res 10 174-180
[9]  
Huang LH(2003)The study of metal ion release and cytotoxicity in Co–Cr–Mo and Ti–Al–V alloy in total knee prosthesis—scanning electron microscopic observation J Mater Sci Mater Med 14 79-86
[10]  
Shotwell JL(2009)Survival and failure rates of orthodontic temporary anchorage devices: a systematic review Clin Oral Implants Res 20 1351-1359