Towards analytically useful two-dimensional Fourier transform ion cyclotron resonance mass spectrometry

被引:0
作者
Maria A. van Agthoven
Marc-André Delsuc
Geoffrey Bodenhausen
Christian Rolando
机构
[1] Miniaturisation pour la Synthèse l’Analyse et la Protéomique,U 596 and UMR CNRS 7104, Institut de Génétique et de Biologie Moléculaire et Cellulaire, INSERM
[2] USR CNRS 3290,UMR 7203, Département de Chimie
[3] Institut Michel-Eugène Chevreul,undefined
[4] FR CNRS 2638 and Protéomique,undefined
[5] Modifications Post-Traductionnelles et Glycobiologie,undefined
[6] IFR 147 Université de Lille 1,undefined
[7] Sciences et Technologie,undefined
[8] Université de Strasbourg,undefined
[9] École Normale Supérieure,undefined
来源
Analytical and Bioanalytical Chemistry | 2013年 / 405卷
关键词
Mass spectrometry; Fourier transform ion cyclotron resonance; Two-dimensional; FT-ICR;
D O I
暂无
中图分类号
学科分类号
摘要
Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry (MS) achieves high resolution and mass accuracy, allowing the identification of the raw chemical formulae of ions in complex samples. Using ion isolation and fragmentation (MS/MS), we can obtain more structural information, but MS/MS is time- and sample-consuming because each ion must be isolated before fragmentation. In 1987, Pfändler et al. proposed an experiment for 2D FT-ICR MS in order to fragment ions without isolating them and to visualize the fragmentations of complex samples in a single 2D mass spectrum, like 2D NMR spectroscopy. Because of limitations of electronics and computers, few studies have been conducted with this technique. The improvement of modern computers and the use of digital electronics for FT-ICR hardware now make it possible to acquire 2D mass spectra over a broad mass range. The original experiments used in-cell collision-induced dissociation, which caused a loss of resolution. Gas-free fragmentation modes such as infrared multiphoton dissociation and electron capture dissociation allow one to measure high-resolution 2D mass spectra. Consequently, there is renewed interest to develop 2D FT-ICR MS into an efficient analytical method. Improvements introduced in 2D NMR spectroscopy can also be transposed to 2D FT-ICR MS. We describe the history of 2D FT-ICR MS, introduce recent improvements, and present analytical applications to map the fragmentation of peptides. Finally, we provide a glossary which defines a few keywords for the 2D FT-ICR MS field.
引用
收藏
页码:51 / 61
页数:10
相关论文
共 50 条
  • [41] Early Days of Two-Dimensional Ion Cyclotron Resonance
    Bodenhausen, Geoffrey
    MOLECULES, 2021, 26 (11):
  • [42] Salvation of acylium fragment ions in electrospray ionization quadrupole ion trap and Fourier transform ion cyclotron resonance mass spectrometry
    Guan, ZQ
    Liesch, JM
    JOURNAL OF MASS SPECTROMETRY, 2001, 36 (03): : 264 - 276
  • [43] Characterization of Polyolefin Pyrolysis Species Produced Under Ambient Conditions by Fourier Transform Ion Cyclotron Resonance Mass Spectrometry and Ion Mobility-Mass Spectrometry
    Farenc, Mathilde
    Witt, Matthias
    Craven, Kirsten
    Barrere-Mangote, Caroline
    Afonso, Carlos
    Giusti, Pierre
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2017, 28 (03) : 507 - 514
  • [44] Compositional analysis for identification of arson accelerants by electron ionization Fourier transform ion cyclotron resonance high-resolution mass spectrometry
    Rodgers, RP
    Blumer, EN
    Freitas, MA
    Marshall, AG
    JOURNAL OF FORENSIC SCIENCES, 2001, 46 (02) : 268 - 279
  • [45] FAST NEUTRAL BEAM FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY FOR ANALYSIS OF INSULATING AND CONDUCTIVE MATERIALS
    LIMBACH, PA
    KIM, HS
    HILL, NC
    MARSHALL, AG
    ANALYTICA CHIMICA ACTA, 1993, 277 (01) : 31 - 39
  • [46] Using a website to explain Fourier transform ion ciclotron resonance mass spectrometry.
    Xavier, LA
    Sena, M
    Ferreira, RS
    Linnert, HV
    Menegon, JJ
    de Souza, LAG
    QUIMICA NOVA, 2001, 24 (03): : 412 - 415
  • [47] Capillary electrophoresis and electron capture dissociation Fourier transform ion cyclotron resonance mass spectrometry for peptide mixture and protein digest analysis
    Tsybin, YO
    Håkansson, P
    Wetterhall, M
    Markides, KE
    Bergquist, J
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2002, 8 (05) : 389 - 395
  • [48] Fourier transform ion cyclotron resonance: state of the art
    Marshall, A. G.
    Hendrickson, C. L.
    Ernmetta, M. R.
    Rodgers, R. P.
    Blakney, G. T.
    Nilsson, C. L.
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2007, 13 (01) : 57 - 59
  • [49] Structure characterization of petroleum vacuum residues by in-beam EI Fourier transform ion cyclotron resonance mass spectrometry
    Miyabayashi, K
    Naito, Y
    Tsujimoto, K
    Miyake, M
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2002, 221 (02) : 93 - 105
  • [50] Molecular characterization of lake sediment WEON by Fourier transform ion cyclotron resonance mass spectrometry and its environmental implications
    Zhang, Li
    Wang, Shengrui
    Xu, Yisheng
    Shi, Quan
    Zhao, Haichao
    Jiang, Bin
    Yang, Jiachun
    WATER RESEARCH, 2016, 106 : 196 - 203