Towards analytically useful two-dimensional Fourier transform ion cyclotron resonance mass spectrometry

被引:0
作者
Maria A. van Agthoven
Marc-André Delsuc
Geoffrey Bodenhausen
Christian Rolando
机构
[1] Miniaturisation pour la Synthèse l’Analyse et la Protéomique,U 596 and UMR CNRS 7104, Institut de Génétique et de Biologie Moléculaire et Cellulaire, INSERM
[2] USR CNRS 3290,UMR 7203, Département de Chimie
[3] Institut Michel-Eugène Chevreul,undefined
[4] FR CNRS 2638 and Protéomique,undefined
[5] Modifications Post-Traductionnelles et Glycobiologie,undefined
[6] IFR 147 Université de Lille 1,undefined
[7] Sciences et Technologie,undefined
[8] Université de Strasbourg,undefined
[9] École Normale Supérieure,undefined
来源
Analytical and Bioanalytical Chemistry | 2013年 / 405卷
关键词
Mass spectrometry; Fourier transform ion cyclotron resonance; Two-dimensional; FT-ICR;
D O I
暂无
中图分类号
学科分类号
摘要
Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry (MS) achieves high resolution and mass accuracy, allowing the identification of the raw chemical formulae of ions in complex samples. Using ion isolation and fragmentation (MS/MS), we can obtain more structural information, but MS/MS is time- and sample-consuming because each ion must be isolated before fragmentation. In 1987, Pfändler et al. proposed an experiment for 2D FT-ICR MS in order to fragment ions without isolating them and to visualize the fragmentations of complex samples in a single 2D mass spectrum, like 2D NMR spectroscopy. Because of limitations of electronics and computers, few studies have been conducted with this technique. The improvement of modern computers and the use of digital electronics for FT-ICR hardware now make it possible to acquire 2D mass spectra over a broad mass range. The original experiments used in-cell collision-induced dissociation, which caused a loss of resolution. Gas-free fragmentation modes such as infrared multiphoton dissociation and electron capture dissociation allow one to measure high-resolution 2D mass spectra. Consequently, there is renewed interest to develop 2D FT-ICR MS into an efficient analytical method. Improvements introduced in 2D NMR spectroscopy can also be transposed to 2D FT-ICR MS. We describe the history of 2D FT-ICR MS, introduce recent improvements, and present analytical applications to map the fragmentation of peptides. Finally, we provide a glossary which defines a few keywords for the 2D FT-ICR MS field.
引用
收藏
页码:51 / 61
页数:10
相关论文
共 50 条
  • [31] Synthesis and Characterization of Methylsulfonium Salt in Diesel Fraction Using Electrospray Ionization Fourier Transform Ion Cyclotron Resonance Mass Spectrometry
    Pan Na
    Shi Quan
    Xu Chun-Ming
    Liu Peng
    Zhang Ya-He
    He Jun-Hui
    Zhao Suo-Qi
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 38 (03) : 413 - 416
  • [32] Fourier Transform-Ion Cyclotron Resonance Mass Spectrometry as a Platform for Characterizing Multimeric Membrane Protein Complexes
    Lippens, Jennifer L.
    Nshanian, Michael
    Spahr, Chris
    Egea, Pascal F.
    Loo, Joseph A.
    Campuzano, Iain D. G.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2018, 29 (01) : 183 - 193
  • [34] High performance electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry at low magnetic field
    Gorshkov, MV
    Udseth, HR
    Anderson, GA
    Smith, RD
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2002, 8 (02) : 169 - 176
  • [35] Investigation of the ozonation products of natural complex mixtures using Fourier transform ion cyclotron resonance mass spectrometry
    Kostyukevich, Yury
    Stavitskaya, Anna
    Zherebker, Alexander
    Konstantinova, Marina
    Vlaskin, Mikhail
    Borisova, Ludmila
    Kononikhin, Alexey
    Popov, Igor
    Nikolaev, Eugene
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2017, 23 (04) : 152 - 155
  • [36] Precision profiling and identification of human serum peptides using Fourier transform ion cyclotron resonance mass spectrometry
    Nicolardi, Simone
    Palmblad, Magnus
    Hensbergen, Paul J.
    Tollenaar, Rob A. E. M.
    Deelder, Andre M.
    van der Burgt, Yuri E. M.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (23) : 3457 - 3463
  • [37] Application of glow discharge Fourier-transform ion cyclotron resonance mass spectrometry to isotope ratio measurements
    Barshick, CM
    Goodner, KL
    Watson, CH
    Eyler, JR
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1998, 178 (1-2) : 73 - 79
  • [38] Electron capture dissociation fourier transform ion cyclotron resonance mass spectrometry of cyclodepsipeptides, branched peptides, and ε-peptides
    Cooper, HJ
    Hudgins, RR
    Marshall, AG
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2004, 234 (1-3) : 23 - 35
  • [39] Peculiarities of data interpretation upon direct tissue analysis by Fourier transform ion cyclotron resonance mass spectrometry
    Chagovets, Vitaliy
    Kononikhin, Aleksey
    Starodubtseva, Nataliia
    Kostyukevich, Yury
    Popov, Igor
    Frankevich, Vladimir
    Nikolaev, Eugene
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2016, 22 (03) : 123 - 126
  • [40] Characterization of nitrogen compounds in vacuum residues by electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry
    Miyabayashi, K
    Naito, Y
    Tsujimoto, K
    Miyake, M
    JOURNAL OF THE JAPAN PETROLEUM INSTITUTE, 2004, 47 (05) : 326 - 334