Towards analytically useful two-dimensional Fourier transform ion cyclotron resonance mass spectrometry

被引:0
|
作者
Maria A. van Agthoven
Marc-André Delsuc
Geoffrey Bodenhausen
Christian Rolando
机构
[1] Miniaturisation pour la Synthèse l’Analyse et la Protéomique,U 596 and UMR CNRS 7104, Institut de Génétique et de Biologie Moléculaire et Cellulaire, INSERM
[2] USR CNRS 3290,UMR 7203, Département de Chimie
[3] Institut Michel-Eugène Chevreul,undefined
[4] FR CNRS 2638 and Protéomique,undefined
[5] Modifications Post-Traductionnelles et Glycobiologie,undefined
[6] IFR 147 Université de Lille 1,undefined
[7] Sciences et Technologie,undefined
[8] Université de Strasbourg,undefined
[9] École Normale Supérieure,undefined
来源
Analytical and Bioanalytical Chemistry | 2013年 / 405卷
关键词
Mass spectrometry; Fourier transform ion cyclotron resonance; Two-dimensional; FT-ICR;
D O I
暂无
中图分类号
学科分类号
摘要
Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry (MS) achieves high resolution and mass accuracy, allowing the identification of the raw chemical formulae of ions in complex samples. Using ion isolation and fragmentation (MS/MS), we can obtain more structural information, but MS/MS is time- and sample-consuming because each ion must be isolated before fragmentation. In 1987, Pfändler et al. proposed an experiment for 2D FT-ICR MS in order to fragment ions without isolating them and to visualize the fragmentations of complex samples in a single 2D mass spectrum, like 2D NMR spectroscopy. Because of limitations of electronics and computers, few studies have been conducted with this technique. The improvement of modern computers and the use of digital electronics for FT-ICR hardware now make it possible to acquire 2D mass spectra over a broad mass range. The original experiments used in-cell collision-induced dissociation, which caused a loss of resolution. Gas-free fragmentation modes such as infrared multiphoton dissociation and electron capture dissociation allow one to measure high-resolution 2D mass spectra. Consequently, there is renewed interest to develop 2D FT-ICR MS into an efficient analytical method. Improvements introduced in 2D NMR spectroscopy can also be transposed to 2D FT-ICR MS. We describe the history of 2D FT-ICR MS, introduce recent improvements, and present analytical applications to map the fragmentation of peptides. Finally, we provide a glossary which defines a few keywords for the 2D FT-ICR MS field.
引用
收藏
页码:51 / 61
页数:10
相关论文
共 50 条
  • [21] Fourier transform ion cyclotron resonance mass spectrometry study of mesomeric heterocyclic betainium ions
    Mäkinen, M
    Vainiotalo, P
    Schmidt, A
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2000, 6 (03) : 259 - 265
  • [22] Molecular characterization of petroporphyrins in crude oil by electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry
    Rodgers, RP
    Hendrickson, CL
    Emmett, MR
    Marshall, AG
    Greaney, M
    Qian, KN
    CANADIAN JOURNAL OF CHEMISTRY, 2001, 79 (5-6) : 546 - 551
  • [23] Direct Analysis in Real Time (DART) of an Organothiophosphate at Ultrahigh Resolution by Fourier Transform Ion Cyclotron Resonance Mass Spectrometry and Tandem Mass Spectrometry
    Prokai, Laszlo
    Stevens, Stanley M., Jr.
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2016, 17 (01)
  • [24] 21 Tesla Fourier Transform Ion Cyclotron Resonance Mass Spectrometer Greatly Expands Mass Spectrometry Toolbox
    Shaw, Jared B.
    Lin, Tzu-Yung
    Leach, Franklin E., III
    Tolmachev, Aleksey V.
    Tolic, Nikola
    Robinson, Errol W.
    Koppenaal, David W.
    Pasa-Tolic, Ljiljana
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2016, 27 (12) : 1929 - 1936
  • [25] Chemical profiling of bioactive constituents in hop cones and pellets extracts by online comprehensive two-dimensional liquid chromatography with tandem mass spectrometry and direct infusion Fourier transform ion cyclotron resonance mass spectrometry
    Sommella, Eduardo
    Pagano, Francesco
    Salviati, Emanuela
    Chieppa, Marcello
    Bertamino, Alessia
    Manfra, Michele
    Sala, Marina
    Novellino, Ettore
    Campiglia, Pietro
    JOURNAL OF SEPARATION SCIENCE, 2018, 41 (07) : 1548 - 1557
  • [26] Laser-induced acoustic desorption/chemical ionization in Fourier-transform ion cyclotron resonance mass spectrometry
    Pérez, J
    Ramírez-Arizmendi, LE
    Petzold, CJ
    Guler, LP
    Nelson, ED
    Kenttämaa, HI
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2000, 198 (03) : 173 - 188
  • [27] Letter: Identification of polyborate ions in aqueous solution by electrospray ionisation Fourier transform ion cyclotron resonance mass spectrometry
    Gaspar, Andras
    Schmitt-Kopplin, Philippe
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2010, 16 (02) : 237 - 242
  • [28] Petroleomic Characterization of Bio-Oil Aging using Fourier-Transform Ion Cyclotron Resonance Mass Spectrometry
    Smith, Erica A.
    Thompson, Christopher
    Lee, Young Jin
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2014, 35 (03) : 811 - 814
  • [29] Synthesis and Characterization of Methylsulfonium Salt in Diesel Fraction Using Electrospray Ionization Fourier Transform Ion Cyclotron Resonance Mass Spectrometry
    Pan Na
    Shi Quan
    Xu Chun-Ming
    Liu Peng
    Zhang Ya-He
    He Jun-Hui
    Zhao Suo-Qi
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 38 (03) : 413 - 416
  • [30] Specific electrochemical iodination of horse heart myoglobin at tyrosine 103 as determined by Fourier transform ion cyclotron resonance mass spectrometry
    Iniesta, Jesus
    Cooper, Helen J.
    Marshall, Alan G.
    Heptinstall, John
    Walton, David J.
    Peterson, Ian R.
    ARCHIVES OF BIOCHEMISTRY AND BIOPHYSICS, 2008, 474 (01) : 1 - 7