Discrete-time sliding mode control with power rate exponential reaching law of a pneumatic artificial muscle system

被引:0
作者
Quy-Thinh Dao
Trung-Kien Le Tri
Van-Anh Nguyen
Manh-Linh Nguyen
机构
[1] Hanoi University of Science and Technology,School of Electrical and Electronic Engineering
来源
Control Theory and Technology | 2022年 / 20卷
关键词
Pneumatic artificial muscle; Discrete-time sliding mode control; Exponential reaching law; Chattering;
D O I
暂无
中图分类号
学科分类号
摘要
This paper develops a discrete-time sliding mode controller with a power rate exponential reaching law approach to enhance the performance of a pneumatic artificial muscle system in both reaching time and chattering reduction. The proposed method dynamically adapts to the variation of the switching function, which is based on an exponential term and a power rate term of the sliding surface. Thus, the controlled system can achieve high tracking performance while still obtain chattering-free control. Moreover, the effectiveness of the proposed method is validated through multiple experimental tests, focused on a dual pneumatic artificial muscle system. Finally, experimental results show the effectiveness of the proposed approach in this paper.
引用
收藏
页码:514 / 524
页数:10
相关论文
共 72 条
[1]  
Chavoshian M(2020)Recurrent neuro-fuzzy model of pneumatic artificial muscle position Journal of Mechanical Science and Technology 34 499-508
[2]  
Taghizadeh M(2019)Trajectory tracking control for double-joint manipulator systems driven by pneumatic artificial muscles based on a nonlinear extended state observer Mechanical Systems and Signal Processing 122 307-320
[3]  
Zhao L(2019)Dynamic analysis of pneumatic artificial muscle (PAM) actuator for rehabilitation with principal parametric resonance condition Nonlinear Dynamics 97 2271-2289
[4]  
Liu X(2009)Robot assisted gait training with active leg exoskeleton (ALEX) IEEE Transactions on Neural Systems and Rehabilitation Engineering 17 2-8
[5]  
Wang T(2018)Assist-as-needed control of a robotic orthosis actuated by pneumatic artificial muscle for gait rehabilitation Applied Sciences 8 499-919
[6]  
Kalita B(2013)Control of a robotic orthosis for gait rehabilitation Robotics and Autonomous Systems 61 911-6937
[7]  
Dwivedy SK(2014)Advanced nonlinear PID-based antagonistic control for pneumatic muscle actuators IEEE Transactions on Industrial Electronics 61 6926-716
[8]  
Banala SK(2011)Hybrid control of a pneumatic artificial muscle (PAM) robot arm using an inverse Narx fuzzy model Engineering Applications of Artificial Intelligence 24 697-1900
[9]  
Kim SH(2020)A method for the length-pressure hysteresis modeling of pneumatic artificial muscles Science China Technological Sciences 63 1869-224
[10]  
Agrawal SK(2018)Hysteresis modeling and trajectory tracking control of the pneumatic muscle actuator using modified Prandtl–Ishlinskii model Mechanism and Machine Theory 120 213-186