On-line, non-Newtonian capillary rheometry for continuous and in-line coatings production

被引:0
|
作者
Shicong Luo
Claus Erik Weinell
Fridolin Okkels
Anders Landeira Østergård
Søren Kiil
机构
[1] Technical University of Denmark,Department of Chemical and Biochemical Engineering
[2] Fluidan Aps,undefined
来源
Journal of Coatings Technology and Research | 2021年 / 18卷
关键词
On-line measurement; Quality control; Viscosity; Capillary rheometer;
D O I
暂无
中图分类号
学科分类号
摘要
Moving from traditional batch production into in-line or continuous coatings production requires accurate on-line quality control instruments. The aim of the present work was to investigate the principle of non-Newtonian capillary rheometry for quality control purposes. In the investigation, three series of acrylic-based viscoelastic coating samples with different types and concentrations of pigments and thickening agents were used, and the rheological measurements were compared to results obtained with the so-called Stormer viscometer and an advanced off-line rheometer. A detailed analysis of the potential measurement implications was also conducted. For shear stresses from 15.0 to 350.0 Pa (the upper boundary), the novel capillary rheometer was found to provide results in good quantitative agreement with the advanced rheometer when sample holding time, and thereby shear history, was properly controlled. At a shear stress between 1.0 Pa (lower boundary) and 15.0 Pa, the agreement was not as good, with a difference in results of the non-Newtonian capillary rheometer and the advanced rheometer between 15% and 74%. The resolution of the capillary rheometer was sufficiently high to allow detection of the rheology changes associated with variations in coating formulations of pigment volume and rheology modifier concentrations. In summary, for fast on-line evaluation of coating rheology, the principle of capillarity has been demonstrated to be a varied and robust technique.
引用
收藏
页码:611 / 626
页数:15
相关论文
共 36 条
  • [21] Monitoring of the methanolysis reaction for biodiesel production by off-line and on-line refractive index and speed of sound measurements
    Zabala, S.
    Arzamendi, G.
    Reyero, I.
    Gandia, L. M.
    FUEL, 2014, 121 : 157 - 164
  • [22] Non-destructive technique for on-line determination of fruit and vegetable quality
    Damyanov, C
    Georgiev, A
    Kostadinova, L
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON QUALITY IN CHAINS, VOLS 1 AND 2: AN INTEGRATED VIW ON FRUIT AND VEGETABLE QUALITY, 2003, (604): : 577 - 584
  • [23] Thermohydrostatic analysis of capillary compensated symmetric hole-entry hybrid journal bearing operating with non-Newtonian lubricant
    Garg, H. C.
    Kumar, Vijay
    Sharda, H. B.
    INDUSTRIAL LUBRICATION AND TRIBOLOGY, 2009, 61 (01) : 11 - 21
  • [24] A Non-Destructive Technique for the On-Line Quality Control of Green and Baked Anodes
    Benzaoui, Abderrahmane
    Kocaefe, Duygu
    Bhattacharyay, Dipankar
    Kocaefe, Yasar
    METALS, 2017, 7 (04):
  • [25] In-line rheological characterisation of wastewater sludges using non-invasive ultrasound sensor technology
    Kotze, R.
    Haldenwang, R.
    Fester, V.
    Roessle, W.
    WATER SA, 2015, 41 (05) : 683 - 690
  • [26] Energy loss analysis of volute centrifugal pump handling non-Newtonian emulsions through entropy production theory
    Achour, Lila
    Specklin, Mathieu
    Asuaje, Miguel
    Kouidri, Smaine
    Belaidi, Idir
    MECHANICS & INDUSTRY, 2024, 25
  • [27] Monitoring biofilm thickness using a non-destructive, on-line, electrical capacitance technique
    Mauricio, R.
    Dias, C. J.
    Santana, F.
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2006, 119 (1-3) : 599 - 607
  • [28] Monitoring Biofilm Thickness Using A Non-Destructive, On-Line, Electrical Capacitance Technique
    R. Maurício
    C. J. Dias
    F. Santana
    Environmental Monitoring and Assessment, 2006, 119 : 599 - 607
  • [29] Continuous on-line measurement of solid moisture content during fluidized bed drying using triboelectric probes
    Portoghese, Federica
    Berruti, Franco
    Briens, Cedric
    POWDER TECHNOLOGY, 2008, 181 (02) : 169 - 177
  • [30] Polynomial ARMA model identification for a continuous styrene polymerization reactor using on-line measurements of polymer properties
    Na, SS
    Rhee, HK
    JOURNAL OF APPLIED POLYMER SCIENCE, 2000, 76 (13) : 1889 - 1901