Regional survey of image quality and radiation dose in computed tomography examinations in Saudi Arabia

被引:0
作者
M. K. Saeed
A. S. Alzoubi
J. M. Al-Qahtani
机构
[1] Najran University,Department of Radiological Sciences
[2] Najran University,College of Medicine
来源
Australasian Physical & Engineering Sciences in Medicine | 2014年 / 37卷
关键词
CT; Image quality; CTDI; Fabricated Phantom;
D O I
暂无
中图分类号
学科分类号
摘要
This study is the first regional investigation in Najran, Saudi Arabia aimed at investigating radiation dose and image quality of computed tomography (CT) examinations. The survey data was collected from five scanners in four hospitals. For all CT scanners, a correction factor was calculated to measure the weighted computed tomography dose index (CTDIw\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$_{w}$$\end{document}) using standard dosimetry phantoms. The CTDIw\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$_{w}$$\end{document} were reported in this study and compared with other countries. It was found that most CTDIw\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$_{w}$$\end{document} values were close to the European reference levels and in line with the results of similar surveys in the other parts of world. Concerning image quality, 80 % of the scanners were found to be in compliance with the relative international guidelines for all the examined parameters
引用
收藏
页码:279 / 283
页数:4
相关论文
共 72 条
  • [1] Treier R(2010)Patient doses in CT examinations in Switzerland: implementation of national diagnostic reference levels Radiat Prot Dosim 142 244-254
  • [2] Aroua A(2012)Towards dose reduction in CT: patient radiation dose assessment for CT examinations at university health center in Canada and comparison with national diagnostic reference levels Radiat Prot Dosim 148 202-210
  • [3] Verdun FR(2006)Current status of patient radiation doses from computed tomography examinations in Tanzania Radiat Prot Dosim 121 128-135
  • [4] Samara E(1995)Patient dose and image quality for computer tomography in several Dutch hospitals Radiat Prot Dosim 57 129-133
  • [5] Stuessi A(2009)Regional survey of CT dose indices in India Radiat Prot Dosim 136 222-227
  • [6] Trueb PhR(2011)Management of patient dose in radiology in the UK Radiat Prot Dosim 147 355-372
  • [7] Héliou R(2011)Image quality and patient dose in computed tomography examinations in Greece Radiat Prot Dosim 147 129-132
  • [8] Normandeau L(2012)Assessment of paediatric CT exposure in a Portuguese hospital Radiat Prot Dosim 151 456-462
  • [9] Beaudoin G(2007)Patient dose measurements in diagnostic radiology procedures in Korea Radiat Prot Dosim 123 540-545
  • [10] Ngaile JE(2008)Overview of patient dosimetry in diagnostic radiology in the USA for the past 50 years Med Phys 35 5713-5728