Acoustic Radiation Force Impulse (ARFI) technique in ultrasound with Virtual Touch tissue quantification of the upper abdomen

被引:225
作者
Gallotti, A. [1 ]
D'Onofrio, M. [1 ]
Mucelli, R. Pozzi [1 ]
机构
[1] Univ Verona, Ist Radiol, Policlin GB Rossi, I-37134 Verona, Italy
来源
RADIOLOGIA MEDICA | 2010年 / 115卷 / 06期
关键词
ARFI ultrasound imaging; Virtual Touch tissue quantification; Healthy abdominal organs; IN-VIVO; TRANSIENT ELASTOGRAPHY; CLINICAL-APPLICATION; MODULUS; SONOELASTOGRAPHY; DIAGNOSIS; STIFFNESS;
D O I
10.1007/s11547-010-0504-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose. Virtual Touch tissue quantification is an implementation of ultrasound (US) Acoustic Radiation Force Impulse (ARFI) imaging that provides numerical measurements (wave-velocity values) of tissue stiffness. The aim of this study was to define the normal values of shear-wave speed for the healthy liver, gallbladder, pancreas, spleen and kidneys. Materials and methods. Thirty-five young healthy volunteers underwent Virtual Touch tissue quantification after having signed an informed consent form. All upper abdominal organs were examined by two independent operators. A phantom fluid model was also evaluated. All mean wave-velocity values were analysed and compared. Results. One hundred and forty measurements of liver, pancreas, spleen and kidneys, and 70 measurements of the gallbladder lumen were performed. Twenty measurements on the phantom were also performed. Comparing all measurements separately made by each operator in different parts of the organs, no statistically significant differences were observed. A "XXXX/0" value was always obtained from all measurements performed on the gallbladder lumen and on the phantom fluid model. Liver, pancreas, spleen and kidney mean values were 1.59 m/s, 1.40 m/s, 2.44 m/s and 2.24 m/s, respectively. Conclusions. Virtual Touch tissue quantification is a new, promising implementation of the US ARFI technique, which provides numerical measurements of tissue stiffness. The mean shear-wave speed is lower in the pancreatic parenchyma than in the liver and kidney, whereas the spleen is characterised by the highest mean value. In simple fluids such as water, the value identified by the system with "XXXX" or 0, is always measured.
引用
收藏
页码:889 / 897
页数:9
相关论文
共 26 条
[1]   Elastography in the detection of prostatic cancer [J].
Cochlin, DL ;
Ganatra, RH ;
Griffiths, DFR .
CLINICAL RADIOLOGY, 2002, 57 (11) :1014-1020
[2]   In vivo visualization of abdominal malignancies with acoustic radiation force elastography [J].
Fahey, B. J. ;
Nelson, R. C. ;
Bradway, D. P. ;
Hsu, S. J. ;
Dumont, D. M. ;
Trahey, G. E. .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (01) :279-293
[3]   The impact of physiological motion on tissue tracking during radiation force imaging [J].
Fahey, Brian J. ;
Palmeri, Mark L. ;
Trahey, Gregg E. .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2007, 33 (07) :1149-1166
[4]  
Garra Brian Stephen, 2007, Ultrasound Q, V23, P255, DOI 10.1097/ruq.0b013e31815b7ed6
[5]   Selected methods for imaging elastic properties of biological tissues [J].
Greenleaf, JF ;
Fatemi, M ;
Insana, M .
ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, 2003, 5 :57-78
[6]   In Vivo assessment of myocardial stiffness with acoustic radiation force impulse imaging [J].
Hsu, Stephen J. ;
Bouchard, Richard R. ;
Dumont, Douglas M. ;
Wolf, Patrick D. ;
Trahey, Gregg E. .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2007, 33 (11) :1706-1719
[7]   Breast disease: Clinical application of US elastography for diagnosis [J].
Itoh, A ;
Ueno, E ;
Tohno, E ;
Kamma, H ;
Takahashi, H ;
Shiina, T ;
Yamakawa, M ;
Matsumura, T .
RADIOLOGY, 2006, 239 (02) :341-350
[8]  
Lamproye A, 2007, Rev Med Liege, V62 Spec No, P68
[9]   Viscoelastic property measurement in thin tissue constructs using ultrasound [J].
Liu, Dalong ;
Ebbini, Emad S. .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2008, 55 (02) :368-383
[10]   Thyroid gland tumor diagnosis at US elastography [J].
Lyshchik, A ;
Higashi, T ;
Asato, R ;
Tanaka, S ;
Ito, J ;
Mai, JJ ;
Pellot-Barakat, C ;
Insana, MF ;
Brill, AB ;
Saga, T ;
Hiraoka, M ;
Togashi, K .
RADIOLOGY, 2005, 237 (01) :202-211