Ultrasensitive non-enzymatic glucose sensing at near-neutral pH values via anodic stripping voltammetry using a glassy carbon electrode modified with Pt3Pd nanoparticles and reduced graphene oxide

被引:0
作者
Li Zhao
Genghuang Wu
Zhixiong Cai
Tingting Zhao
Qiuhong Yao
Xi Chen
机构
[1] Xiamen Huaxia College,MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, College of Chemistry and Chemical Engineering
[2] Xiamen University,undefined
来源
Microchimica Acta | 2015年 / 182卷
关键词
Anodic stripping voltammetry; Platinum nanoparticles; Palladium nanoparticles; Reduced graphene oxide; Glucose;
D O I
暂无
中图分类号
学科分类号
摘要
We describe an anodic stripping voltammetric (ASV) method for glucose sensing that widely expands the typical amperometric i-t response of glucose sensors. The electrode is based on a working electrode consisting of a glassy carbon electrode modified with Pt-Pd nanoparticles (NPs; in an atomic ratio of 3:1) on a reduced graphene oxide (rGO) support. The material was prepared via the spontaneous redox reaction between rGO, PdCl42− and PtCl42− without any additional reductant or surfactant. Unlike known Pt-based sensors, the use of Pt3Pd NPs results in an ultrasensitive ASV approach for sensing glucose even at near-neutral pH values. If operated at a working voltage as low as 0.06 V (vs. SCE), the modified electrode can detect glucose in the 2 nM to 300 μM concentration range. The lowest detectable concentration is 2 nM which is much lower than the LODs obtained with other amperometric i-t type sensing approaches, most of which have LODs at a μM level. The sensor is not interfered by the presence of 0.1 M of NaCl.
引用
收藏
页码:2055 / 2060
页数:5
相关论文
共 114 条
[21]  
Yao S(2008)Langmuir-Blodgett assembly of graphite oxide single layers J Am Chem Soc 131 1043-undefined
[22]  
Toghill K(2008)Nonenzymatic electrochemical glucose sensor based on nanoporous PtPb networks Anal Chem 80 997-undefined
[23]  
Compton R(2011)Direct electrodeposition of reduced graphene oxide on glassy carbon electrode and its electrochemical application Electrochem Commun 13 133-undefined
[24]  
Wang G(2009)Nonenzymatic glucose sensor based on ultrasonic-electrodeposition of bimetallic PtM (M = Ru, Pd and Au) nanoparticles on carbon nanotubes-ionic liquid composite film Biosens Bioelectron 24 3481-undefined
[25]  
He X(2003)Nonenzymatic glucose detection using mesoporous platinum Anal Chem 75 3046-undefined
[26]  
Wang L(2010)Nonenzymatic amperometric sensing of glucose by using palladium nanoparticles supported on functional carbon nanotubes Biosens Bioelectron 25 1803-undefined
[27]  
Gu A(2011)Synthesis of “clean” and well-dispersive Pd nanoparticles with excellent electrocatalytic property on graphene oxide J Am Chem Soc 133 3693-undefined
[28]  
Huang Y(undefined)undefined undefined undefined undefined-undefined
[29]  
Fang B(undefined)undefined undefined undefined undefined-undefined
[30]  
Geng B(undefined)undefined undefined undefined undefined-undefined