Observability enhancement by optimal PMU placement considering random power system outages

被引:42
作者
Aminifar F. [1 ]
Fotuhi-Firuzabad M. [1 ]
Shahidehpour M. [2 ]
Khodaei A. [2 ]
机构
[1] Electrical Engineering Department, Sharif University of Technology, Tehran
[2] Electrical and Computer Engineering Department, Illinois Institute of Technology, Chicago
基金
美国国家科学基金会;
关键词
Phasor measurement units; Probabilistic assessment; System observability analysis; Wide-area measurement;
D O I
10.1007/s12667-011-0025-x
中图分类号
学科分类号
摘要
This paper enhances the observability of power networks by taking into consideration random component outages. The architecture of wide-area measurement system (WAMS) is analyzed in order to identify components that would affect the network observability. An iterative framework is devised to calculate a bus index in power networks equipped with phasor measurement units (PMUs) and conventional measurements. The average of bus indices represents a system index which provides an overall insight on the power network observability. The system index is utilized as a criterion to distinguish among multiple optimal PMU placements. Conventional bus injection and line flow measurements and the effect of zero-injection buses are considered in the proposed model. The numerical analyses are carried out for the proposed model and the results are discussed in detail. © 2011 Springer-Verlag.
引用
收藏
页码:45 / 65
页数:20
相关论文
共 50 条
  • [1] Optimal PMU placement for power system observability using BICA, considering measurement redundancy
    Mahari, Arash
    Seyedi, Heresh
    ELECTRIC POWER SYSTEMS RESEARCH, 2013, 103 : 78 - 85
  • [2] Optimal PMU Placement in a Power Network for Full System Observability
    Fish, Abdul-Aziz
    Chowdhury, S.
    Chowdhury, S. P.
    2011 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2011,
  • [3] Optimal Placement of PMU for Complete Observability of Power System Considering Zero Injection and Islanding Condition
    Devendran, Vidhya Sagar
    Jasni, Jasronita
    Radzi, Mohd Amran Mohd
    Azis, Norhafiz
    2020 IEEE INTERNATIONAL CONFERENCE ON POWER AND ENERGY (PECON 2020), 2020, : 107 - 112
  • [4] Optimal PMU placement for power system observability considering network expansion and N-1 contingencies
    Asgari, Abdolrahim
    Firouzjah, Khalil Gorgani
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2018, 12 (18) : 4216 - 4224
  • [5] OBSERVABILITY AND REDUNDANCY BASED PMU PLACEMENT AT OPTIMAL LOCATION OF POWER SYSTEM
    Narayana, P. Lakshmi
    Venkatesan, M.
    JOURNAL OF MECHANICS OF CONTINUA AND MATHEMATICAL SCIENCES, 2019, 14 (06): : 623 - 633
  • [6] Deep Reinforcement Learning-Based Optimal PMU Placement Considering the Degree of Power System Observability
    Zhou, Xu
    Wang, Yuhong
    Shi, Yunxiang
    Jiang, Qiliang
    Zhou, Chenyu
    Zheng, Zongsheng
    IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2024, 20 (06) : 8949 - 8960
  • [7] An optimal PMU placement method for power system observability under various contingencies
    Abiri, Ebrahim
    Rashidi, Farzan
    Niknam, Taher
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2015, 25 (04): : 589 - 606
  • [8] Optimal PMU placement for power system observability using Taguchi binary bat algorithm
    Vedik, Basetti
    Chandel, Ashwani K.
    MEASUREMENT, 2017, 95 : 8 - 20
  • [9] Optimal PMU placement method for complete topological observability of power system under various contingencies
    Abiri, Ebrahim
    Rashidi, Farzan
    Niknam, Taher
    Salehi, Mohammad Reza
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2014, 61 : 585 - 593
  • [10] Observability Constrained GA Approach for Optimal PMU Placement considering Zero Injection Modeling
    Sushma, G. Chandana
    Jyothsna, T. R.
    2018 INTERNATIONAL CONFERENCE ON CONTROL, POWER, COMMUNICATION AND COMPUTING TECHNOLOGIES (ICCPCCT), 2018, : 174 - 178