Coagulation and ablation patterns of high-intensity focused ultrasound on a tissue-mimicking phantom and cadaveric skin

被引:0
|
作者
Hee-Jin Kim
Han Gu Kim
Zhenlong Zheng
Hyoun Jun Park
Jeung Hyun Yoon
Wook Oh
Cheol Woo Lee
Sung Bin Cho
机构
[1] Yonsei University College of Dentistry,Division of Anatomy and Developmental Biology, Department of Oral Biology, Human Identification Research Center
[2] Baekseol Gonju Clinic,Department of Dermatology and Cutaneous Biology Research Institute
[3] Yonsei University College of Medicine,Department of Dermatology
[4] Yanbian University Hospital,undefined
[5] Maylin Clinic,undefined
[6] Yonseifams Clinic,undefined
[7] Samsung Feel Clinic,undefined
[8] WITH ME Clinic,undefined
[9] Kangskin Dermatology Clinic,undefined
来源
Lasers in Medical Science | 2015年 / 30卷
关键词
High-intensity focused ultrasound; Coagulation; Ablation; Tissue phantom; Cadaver; Comparison study;
D O I
暂无
中图分类号
学科分类号
摘要
High-intensity focused ultrasound (HIFU) can be applied noninvasively to create focused zones of tissue coagulation on various skin layers. We performed a comparative study of HIFU, evaluating patterns of focused tissue coagulation and ablation upon application thereof. A tissue-mimicking (TM) phantom was prepared with bovine serum albumin and polyacrylamide hydrogel to evaluate the geometric patterns of HIFU-induced thermal injury zones (TIZs) for five different HIFU devices. Additionally, for each device, we investigated histologic patterns of HIFU-induced coagulation and ablation in serial sections of cadaveric skin of the face and neck. All HIFU devices generated remarkable TIZs in the TM phantom, with different geometric values of coagulation for each device. Most of the TIZs seemed to be separated into two or more tiny parts. In cadaveric skin, characteristic patterns of HIFU-induced ablation and coagulation were noted along the mid to lower dermis at the focal penetration depth of 3 mm and along subcutaneous fat to the superficial musculoaponeurotic system or the platysma muscle of the neck at 4.5 mm. Additionally, remarkable pre-focal areas of tissue coagulation were observed in the upper and mid dermis at the focal penetration depth of 3 mm and mid to lower dermis at 4.5 mm. For five HIFU devices, we outlined various patterns of HIFU-induced TIZ formation along pre-focal, focal, and post-focal areas of TM phantom and cadaveric skin of the face and neck.
引用
收藏
页码:2251 / 2258
页数:7
相关论文
共 50 条
  • [1] Coagulation and ablation patterns of high-intensity focused ultrasound on a tissue-mimicking phantom and cadaveric skin
    Kim, Hee-Jin
    Kim, Han Gu
    Zheng, Zhenlong
    Park, Hyoun Jun
    Yoon, Jeung Hyun
    Oh, Wook
    Lee, Cheol Woo
    Cho, Sung Bin
    LASERS IN MEDICAL SCIENCE, 2015, 30 (09) : 2251 - 2258
  • [2] Development and Characterization of a Tissue-Mimicking Material for High-Intensity Focused Ultrasound
    King, Randy L.
    Liu, Yunbo
    Maruvada, Subha
    Herman, Bruce A.
    Wear, Keith A.
    Harris, Gerald R.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2011, 58 (07) : 1397 - 1405
  • [3] Boiling activity induced by high intensity focused ultrasound in a tissue-mimicking phantom
    Kang, Hwi Suk
    Lee, Kang Il
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2020, 59 (02)
  • [4] AN IMPROVED TISSUE-MIMICKING POLYACRYLAMIDE HYDROGEL PHANTOM FOR VISUALIZING THERMAL LESIONS WITH HIGH-INTENSITY FOCUSED ULTRASOUND
    Guntur, Sitaramanjaneya Reddy
    Choi, Min Joo
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2014, 40 (11): : 2680 - 2691
  • [5] SIMULTANEOUS EVALUATION OF THERMAL AND NON-THERMAL EFFECTS OF HIGH-INTENSITY FOCUSED ULTRASOUND ON A TISSUE-MIMICKING PHANTOM
    Kim, Yong Tae
    Ma, Donghee
    Sim, Jai Kyoung
    Kim, Se-Hwa
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2018, 44 (08): : 1799 - 1809
  • [6] Confocal dual-frequency enhances the damaging effect of high-intensity focused ultrasound in tissue-mimicking phantom
    Kuang, Sheng-Li
    Hu, Bing
    Jiang, Li-Xin
    He, Pei-Zhong
    Xia, Rong-Min
    Shou, Wen-De
    MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2008, 17 (05) : 285 - 291
  • [7] Development of a tissue-mimicking phantom for evaluating the focusing performance of high intensity focused ultrasound
    Jing Zongyu
    Li Faqi
    Zou Hangzhong
    Wang Zhibiao
    THERAPEUTIC ULTRASOUND, 2006, 829 : 648 - +
  • [8] A visualization method for a wide range of rising temperature induced by high-intensity focused ultrasound using a tissue-mimicking phantom
    Takagi, Ryo
    Yoshinaka, Kiyoshi
    Washio, Toshikatsu
    Koseki, Yoshihiko
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2022, 39 (01) : 22 - 33
  • [9] Prediction and Measurement of Temperature Rise Induced by High Intensity Focused Ultrasound in a Tissue-Mimicking Phantom
    Kang Il Lee
    Journal of the Korean Physical Society, 2018, 72 : 1313 - 1319
  • [10] Prediction and Measurement of Temperature Rise Induced by High Intensity Focused Ultrasound in a Tissue-Mimicking Phantom
    Lee, Kang Il
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2018, 72 (11) : 1313 - 1319