Effects of vitamin E incorporation in polyethylene on oxidative degradation, wear rates, immune response, and infections in total joint arthroplasty: a review of the current literature

被引:0
作者
Bart Lambert
Daniëlle Neut
Hugo C. van der Veen
Sjoerd K. Bulstra
机构
[1] University of Groningen,Department of Orthopedic Surgery
[2] University Medical Center Groningen,Department of Biomedical Engineering
[3] University of Groningen,undefined
[4] University Medical Center Groningen,undefined
来源
International Orthopaedics | 2019年 / 43卷
关键词
Vitamin E; UHMWPE; Highly cross-linked polyethylene; Arthroplasty; Wear rates; Infection;
D O I
暂无
中图分类号
学科分类号
摘要
Highly cross-linked ultrahigh molecular weight polyethylene (UHMWPE) was introduced to decrease wear debris and osteolysis. During cross-linking, free radicals are formed, making highly cross-linked polyethylene vulnerable to oxidative degradation. In order to reduce this process, anti-oxidant vitamin E can be incorporated in polyethylene. This review provides an overview of the effects of vitamin E incorporation on major complications in total joint arthroplasty: material failure due to oxidative degradation, wear debris and subsequent periprosthetic osteolysis, and prosthetic joint infections. Secondly, this review summarizes the first clinical results of total hip and knee arthroplasties with vitamin E incorporated highly cross-linked polyethylene. Based on in vitro studies, incorporation of vitamin E in polyethylene provides good oxidative protection and preserves low wear rates. Incorporation of vitamin E may have the beneficial effect of reduced inflammatory response to its wear particles. Some microorganisms showed reduced adherence to vitamin E–incorporated UHMWPE; however, clinical relevance is doubtful. Short-term clinical studies of total hip and knee arthroplasties with vitamin E–incorporated highly cross-linked UHMWPE reported good clinical results and wear rates similar to highly cross-linked UHMWPE without vitamin E.
引用
收藏
页码:1549 / 1557
页数:8
相关论文
共 293 条
[51]  
Kurtz SM(2016)Five-year experience of vitamin E-diffused highly cross-linked polyethylene wear in total hip arthroplasty assessed by radiostereometric analysis J Arthroplast 31 1251-1255
[52]  
Manley M(2017)Vitamin E diffused highly cross-linked polyethylene in total hip arthroplasty at five years: a randomised controlled trial using radiostereometric analysis Bone Joint J 99-B 577-584
[53]  
Wang A(2017)Does vitamin E-blended polyethylene reduce wear in primary total hip arthroplasty: a blinded randomised clinical trial Int Orthop 41 1113-1118
[54]  
Taylor S(2002)A literature review of the association between wear rate and osteolysis in total hip arthroplasty J Arthroplasty 17 649-661
[55]  
Dumbleton J(2016)Early experience with vitamin E antioxidant-infused highly cross-linked polyethylene inserts in primary total knee arthroplasty Surg Technol Int XXIX 334-340
[56]  
Oral E(2015)Early fracture of a vitamin-E-infused, highly cross-linked polyethylene liner after total hip arthroplasty: a case report JBJS Case Connect 5 e65-6
[57]  
Muratoglu OK(2013)Retrieval analysis of an early fracture of a vitamin E-stabilized tibial liner in total knee arthroplasty: a case report JBJS Case Connect 3 1-458
[58]  
Currier BH(2012)Increasing risk of prosthetic joint infection after total hip arthroplasty Acta Orthop 83 449-undefined
[59]  
Currier JH(undefined)undefined undefined undefined undefined-undefined
[60]  
Mayor MB(undefined)undefined undefined undefined undefined-undefined