Copper(II) ion selective electrode based on a newly synthesized Schiff-base chelate

被引:0
|
作者
Ajay Kumar Jain
Raj Kumar Singh
Shalabh Jain
Jitendra Raisoni
机构
[1] Indian Institute of Technology Roorkee,Department of Chemistry
[2] Gurukul Knagri University,Department of Chemistry
[3] Western Digital Media Operation,undefined
[4] Bayan Lepaz,undefined
来源
Transition Metal Chemistry | 2008年 / 33卷
关键词
Dyslexia; Selectivity Coefficient; Copper Chelate; Cold Vapour Atomic Absorption Spectrometry; Selective Sensor;
D O I
暂无
中图分类号
学科分类号
摘要
A new Cu (II) ion-selective electrode has been fabricated in poly (vinyl chloride) matrix based on a recently synthesized Schiff-base chelate. The addition of sodium tetraphenylborate (NaTPB) and various plasticizers viz. TBP, TEHP, DOS, and CN have been found to substantially improve the performance of the electrode. The membrane of various compositions of the ionophore (I) were investigated and it was found that the best performance was obtained with the membrane having (I): PVC: NaTPB: CN in the ratio 4: 140: 3: 80 (mg). The electrode exhibits a Nernstian response over a wide concentration range (1.9 × 10−6–1.0 × 10−1 M) with 30.0 mV/decade of concentration between pH 3.0 and 7.5. The response time of the electrode is about 12 s and it can be used over a period of 3 months without any divergence in potential. The potentiometric selectivity coefficient values as determined by fixed interference method indicate excellent selectivity for Cu2+ ions over interfering cations. The electrode has also been used successfully in partially non-aqueous media having a 25% (v/v) methanol, ethanol or acetone content without showing any considerable change in the value of slope or working concentration range. The electrode has been used in the potentiometric titration of Cu2+ with EDTA.
引用
收藏
页码:243 / 249
页数:6
相关论文
共 50 条
  • [1] Copper(II) ion selective electrode based on a newly synthesized Schiff-base chelate
    Jain, Ajay Kumar
    Singh, Raj Kumar
    Jain, Shalabh
    Raisoni, Jitendra
    TRANSITION METAL CHEMISTRY, 2008, 33 (02) : 243 - 249
  • [2] Novel copper(II)-selective membrane electrode based on a new synthesized Schiff base
    Akhond, Morteza
    Najafi, Mohammad Bagher
    Sharghi, Hashem
    Tashkhourian, Javad
    Naiemi, Hossein
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2007, 54 (02) : 331 - 337
  • [3] IMMOBILIZED CHYMOTRYPSIN BY MEANS OF SCHIFF-BASE COPPER(II)CHELATE
    MORIYA, K
    TANIZAWA, K
    KANAOKA, Y
    BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 1989, 162 (01) : 408 - 414
  • [4] SCHIFF-BASE COPPER(II) CHELATE AS A TOOL FOR IMMOBILIZATION OF PROTEIN
    MORIYA, K
    TANIZAWA, K
    KANAOKA, Y
    CHEMICAL & PHARMACEUTICAL BULLETIN, 1989, 37 (10) : 2849 - 2851
  • [5] Aluminium(III)-selective electrode based on a newly synthesized tetradentate Schiff base
    Abbaspour, A
    Esmaeilbeig, AR
    Jarrahpour, AA
    Khajeh, B
    Kia, R
    TALANTA, 2002, 58 (02) : 397 - 403
  • [6] Fabrication of copper-selective PVC membrane electrode based on newly synthesized copper complex of Schiff base as carrier
    Chandra, Sulekh
    Tomar, Praveen Kumar
    Kumar, Avdhesh
    Malik, Amrita
    Singh, Arendra
    JOURNAL OF SAUDI CHEMICAL SOCIETY, 2016, 20 : S293 - S299
  • [7] Copper (II) ion selective liquid membrane electrode based on new Schiff base carrier
    Sadeghi, S
    Vardini, MT
    Naeimi, H
    ANNALI DI CHIMICA, 2006, 96 (1-2) : 65 - 74
  • [8] Fabrication of PVC Membrane Based Ion Selective Electrode by Using the Newly Synthesised Copper Schiff Base Complex
    Swami, Babu Lal
    Tyagi, Sonika
    Ahmed, Shakeel
    Ikram, Saiqa
    MATERIALS FOCUS, 2015, 4 (03) : 179 - 183
  • [9] SELECTIVE ESTER-EXCHANGE REACTION IN COPPER(II) CHELATE OF SCHIFF-BASE DERIVED FROM SALICYLALDEHYDE AND DIBENZYLASPARTATE
    NAKAO, Y
    NAKAHARA, A
    CHEMISTRY LETTERS, 1977, (02) : 145 - 146
  • [10] Copper(II)-selective membrane electrode based on a recently synthesized naphthol-derivative Schiff's base
    Alizadeh, N
    Ershad, S
    Naeimi, H
    Sharghi, H
    Shamsipur, M
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 365 (06): : 511 - 515