T2* quantification using multi-echo gradient echo sequences: a comparative study of different readout gradients

被引:0
|
作者
Seonyeong Shin
Seong Dae Yun
N. Jon Shah
机构
[1] Forschungszentrum Jülich,Institute of Neuroscience and Medicine 4
[2] RWTH Aachen University,Institute of Neuroscience and Medicine 11
[3] JARA,Department of Neurology
[4] Forschungszentrum Jülich,undefined
[5] JARA-BRAIN-Translational Medicine,undefined
[6] RWTH Aachen University,undefined
来源
Scientific Reports | / 13卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
To quantify T2*, multiple echoes are typically acquired with a multi-echo gradient echo sequence using either monopolar or bipolar readout gradients. The use of bipolar readout gradients achieves a shorter echo spacing time, enabling the acquisition of a larger number of echoes in the same scan time. However, despite their relative time efficiency and the potential for more accurate quantification, a comparative investigation of these readout gradients has not yet been addressed. This work aims to compare the performance of monopolar and bipolar readout gradients for T2* quantification. The differences in readout gradients were theoretically investigated with a Cramér-Rao lower bound and validated with computer simulations with respect to the various imaging parameters (e.g., flip angle, TR, TE, TE range, and BW). The readout gradients were then compared at 3 T using phantom and in vivo experiments. The bipolar readout gradients provided higher precision than monopolar readout gradients in both computer simulations and experimental results. The difference between the two readout gradients increased for a lower SNR and smaller TE range, consistent with the prediction made using Cramér-Rao lower bound. The use of bipolar readout gradients is advantageous for regions or situations where a lower SNR is expected or a shorter acquisition time is required.
引用
收藏
相关论文
共 50 条
  • [1] T2*quantification using multi-echo gradient echo sequences: a comparative study of different readout gradients
    Shin, Seonyeong
    Yun, Seong Dae
    Shah, N. Jon
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [2] Phase-corrected bipolar gradients in multi-echo gradient-echo sequences for quantitative susceptibility mapping
    Li, Jianqi
    Chang, Shixin
    Liu, Tian
    Jiang, Hongwei
    Dong, Fang
    Pei, Mengchao
    Wang, Qianfeng
    Wang, Yi
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2015, 28 (04) : 347 - 355
  • [3] Phase-corrected bipolar gradients in multi-echo gradient-echo sequences for quantitative susceptibility mapping
    Jianqi Li
    Shixin Chang
    Tian Liu
    Hongwei Jiang
    Fang Dong
    Mengchao Pei
    Qianfeng Wang
    Yi Wang
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2015, 28 : 347 - 355
  • [4] Comparison of conventional single echo and multi-echo sequences with a fast spin echo sequence for quantitative T2 mapping: Application to the prostate
    Liney, GP
    Knowles, AJ
    Manton, DJ
    Turnbull, LW
    Blackband, SJ
    Horsman, A
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (04): : 603 - 607
  • [5] Fast T2 Relaxometry with an Accelerated Multi-echo Spin-echo Sequence
    Senegas, Julien
    Liu, Wei
    Dahnke, Hannes
    Song, Hotaek
    Jordan, E. Kay
    Frank, Joseph A.
    NMR IN BIOMEDICINE, 2010, 23 (08) : 958 - 967
  • [6] Simultaneous Quantification of T2 and T2′ Using a Combined Gradient Echo-Spin Echo Sequence at Ultrahigh Field
    Cox, Eleanor F.
    Gowland, Penny A.
    MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (05) : 1441 - 1446
  • [7] Fast T2 mapping using multi-echo spin-echo MRI: A linear order approach
    Fatemi, Yaghoub
    Danyali, Habibollah
    Helfroush, Mohammad Sadegh
    Amiri, Houshang
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (05) : 2815 - 2830
  • [8] Effect of gadolinium on hepatic fat quantification using multi-echo reconstruction technique with T2*correction and estimation
    Ge, Mingmei
    Zhang, Jing
    Wu, Bing
    Liu, Zhiqin
    Song, Hai
    Meng, Xiangfeng
    Wu, Xinhuai
    EUROPEAN RADIOLOGY, 2016, 26 (06) : 1913 - 1920
  • [9] Effect of gadolinium on hepatic fat quantification using multi-echo reconstruction technique with T2* correction and estimation
    Mingmei Ge
    Jing Zhang
    Bing Wu
    Zhiqin Liu
    Hai Song
    Xiangfeng Meng
    Xinhuai Wu
    European Radiology, 2016, 26 : 1913 - 1920
  • [10] New approach to phase correction in multi-echo T2 relaxometry
    Bjork, Marcus
    Stoica, Petre
    JOURNAL OF MAGNETIC RESONANCE, 2014, 249 : 100 - 107