Evaluation of a 3D-printed heterogeneous anthropomorphic head and neck phantom for patient-specific quality assurance in intensity-modulated radiation therapy

被引:0
作者
Noriyuki Kadoya
Kota Abe
Hikaru Nemoto
Kiyokazu Sato
Yoshiro Ieko
Kengo Ito
Suguru Dobashi
Ken Takeda
Keiichi Jingu
机构
[1] Tohoku University Graduate School of Medicine,Department of Radiation Oncology
[2] Tokyo Metropolitan Cancer and Infectious Diseases Center Komagome Hospital,Department of Radiation Oncology
[3] Tohoku University Hospital,Department of Radiology
[4] Yamagata University Faculty of Medicine,Department of Radiation Oncology
[5] Tohoku University,Department of Radiological Technology, School of Health Sciences, Faculty of Medicine
来源
Radiological Physics and Technology | 2019年 / 12卷
关键词
Radiotherapy; Quality assurance; Phantom; Structured exercise; 3D printer; Head and neck ;
D O I
暂无
中图分类号
学科分类号
摘要
We evaluated an anthropomorphic head and neck phantom with tissue heterogeneity, produced using a personal 3D printer, with quality assurance (QA), specific to patients undergoing intensity-modulated radiation therapy (IMRT). Using semi-automatic segmentation, 3D models of bone, soft tissue, and an air-filled cavity were created based on computed tomography (CT) images from patients with head and neck cancer treated with IMRT. For the 3D printer settings, polylactide was used for soft tissue with 100% infill. Bone was reproduced by pouring plaster into the cavity created by the 3D printer. The average CT values for soft tissue and bone were 13.0 ± 144.3 HU and 439.5 ± 137.0 HU, respectively, for the phantom and 12.1 ± 124.5 HU and 771.5 ± 405.3 HU, respectively, for the patient. The gamma passing rate (3%/3 mm) was 96.1% for a nine-field IMRT plan. Thus, this phantom may be used instead of a standard shape phantom for patient-specific QA in IMRT.
引用
收藏
页码:351 / 356
页数:5
相关论文
共 50 条
[21]   Posttreatment Quality-of-Life Assessment in Patients With Head and Neck Cancer Treated With Intensity-modulated Radiation Therapy [J].
O'Neill, Michael ;
Heron, Dwight E. ;
Flickinger, John C. ;
Smith, Ryan ;
Ferris, Robert L. ;
Gibson, Michael .
AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 2011, 34 (05) :478-482
[22]   Evaluation of surface and build-up region dose for intensity-modulated radiation therapy in head and neck cancer [J].
Chung, HT ;
Jin, HS ;
Dempsey, JF ;
Liu, CH ;
Palta, J ;
Suh, TS ;
Kim, SY .
MEDICAL PHYSICS, 2005, 32 (08) :2682-2689
[23]   Validation of Monte Carlo 131I radiopharmaceutical dosimetry workflow using a 3D-printed anthropomorphic head and neck phantom [J].
Adam, David P. ;
Grudzinski, Joseph J. ;
Bormett, Ian ;
Cox, Benjamin L. ;
Marsh, Ian R. ;
Bradshaw, Tyler J. ;
Harari, Paul M. ;
Bednarz, Bryan P. .
MEDICAL PHYSICS, 2022, 49 (08) :5491-5503
[24]   Preparation and fabrication of a full-scale, sagittal-sliced, 3D-printed, patient-specific radiotherapy phantom [J].
Craft, Daniel F. ;
Howell, Rebecca M. .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (05) :285-292
[25]   Evaluation of prediction and classification performances in different machine learning models for patient-specific quality assurance of head-and-neck VMAT plans [J].
Kusunoki, Terufumi ;
Hatanaka, Shogo ;
Hariu, Masatsugu ;
Kusano, Yohsuke ;
Yoshida, Daisaku ;
Katoh, Hiroyuki ;
Shimbo, Munefumi ;
Takahashi, Takeo .
MEDICAL PHYSICS, 2022, 49 (01) :727-741
[26]   Evaluation of dosimetric advantages of using patient-specific aperture system with intensity-modulated proton therapy for the shallow depth tumor [J].
Yasui, Keisuke ;
Toshito, Toshiyuki ;
Omachi, Chihiro ;
Hayashi, Kensuke ;
Tanaka, Kenichiro ;
Asai, Kumiko ;
Shimomura, Akira ;
Muramatsu, Rie ;
Hayashi, Naoki .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (01) :132-137
[27]   Evaluation of a novel phantom for the quality assurance of a six-degree-of-freedom couch 3D-printed at multiple centres [J].
Marshall, Hannah ;
Selvan, Tamil ;
Ahmad, Reem ;
Bento, Mariana ;
Veiga, Catarina ;
Sands, Gordon ;
Malone, Ciaran ;
King, Raymond B. ;
Clark, Catharine H. ;
McGarry, Conor K. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2023, 114
[28]   A systems theory-based safety assessment of pre-treatment patient-specific quality assurance for intensity-modulated treatments in a single-vendor environment [J].
Wong, Lawrence M. ;
Pawlicki, Todd .
RADIOTHERAPY AND ONCOLOGY, 2024, 201
[29]   Evaluation of Delta4DVH Anatomy in 3D Patient-Specific IMRT Quality Assurance [J].
Tang, Du ;
Yang, Zhen ;
Dai, Xunzhang ;
Cao, Ying .
TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2020, 19
[30]   Evaluation of the dynamic conformal arc therapy in comparison to intensity-modulated radiation therapy in prostate, brain, head-and-neck and spine tumors [J].
Morales-Paliza, Manuel A. ;
Coffey, Charles W. ;
Ding, George X. .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2011, 12 (02) :5-19