Hollow Fiber Liquid Phase Microextraction Method Combined with High-Performance Liquid Chromatography for Simultaneous Separation and Determination of Ultra-Trace Amounts of Naproxen and Nabumetone in Cow Milk, Water, and Biological Samples

被引:0
作者
Mohammad Asadi
Shayessteh Dadfarnia
Ali Mohammad Haji Shabani
Bijan Abbasi
机构
[1] Yazd University,Department of Chemistry, Faculty of Science
[2] Khorassan Research Institute for Food Science and Technology,undefined
来源
Food Analytical Methods | 2016年 / 9卷
关键词
Naproxen; Nabumetone; Hollow fiber liquid phase microextraction; HPLC;
D O I
暂无
中图分类号
学科分类号
摘要
A simple and highly sensitive method based on hollow fiber liquid phase microextraction combined with high-performance liquid chromatography and fluorescence detection has been developed for simultaneous separation, preconcentration, and determination of naproxen and nabumetone from water, wastewater, milk, and biological samples. Parameters affecting the microextraction efficiency were evaluated and optimized. Under optimum conditions (extractant (14 μL of 1-undecanol), sample pH (3.0), extraction time (20 min), stirring rate (600 rpm), temperature (45 °C), potassium chloride concentration (4.0 %) and sample volume (9 mL)), the limits of detection based on (S/N = 3) were 1.3 ng L−1 for naproxen and 2.9 ng L−1 for nabumetone. The intra- and inter-assay relative standard deviations for naproxen and nabumetone were in the ranges of 3.2–6.1 % and 6.5–9.5 %, respectively. The calibration curves were linear in concentration ranges of 4.0–300.0 ng L−1 and 9.0–300.0 ng L−1 for naproxen and nabumetone, respectively, with good coefficient of determination (r2 > 0.999). The method was successfully applied to the determination of naproxen and nabumetone in cow milk, water, wastewater, human plasma, and urine samples.
引用
收藏
页码:2762 / 2772
页数:10
相关论文
共 163 条
  • [1] Adhoum N(2003)Determination of naproxen in pharmaceuticals by differential pulse voltammetry at a platinum electrode Anal Chim Acta 495 69-75
  • [2] Monser L(2010)Optimization of a novel method based on solidification of floating organic droplet by high-performance liquid chromatography for evaluation of antifungal drugs in biological samples Talanta 83 370-378
  • [3] Toumi M(2010)Determination of non-steroidal anti-inflammatory drugs in wastewaters by magnetic matrix solid phase dispersion–HPLC Talanta 80 1152-1157
  • [4] Boujlel K(2013)Dispersive liquid–liquid microextraction combined with field-amplified sample stacking in capillary electrophoresis for the determination of non-steroidal anti-inflammatory drugs in milk and dairy products Food Chem 138 890-897
  • [5] Adlnasab L(2015)Solid phase microextraction of diclofenac using molecularly imprinted polymer sorbent in hollow fiber combined with fiber optic-linear array spectrophotometry Spectrochim Acta, Part A 147 26-30
  • [6] Ebrahimzadeh H(2006)Profiling urinary metabolites of naproxen by liquid chromatography–electrospray mass spectrometry J Pharm Biomed Anal 41 1312-1316
  • [7] Yamini Y(2015)Simultaneous extraction and quantification of lamotrigine, phenobarbital and phenytoin in human plasma and urine samples using solidified floating organic drop microextraction and high performance liquid chromatography J Sep Sci 38 2510-2516
  • [8] Mirzajani F(2015)Solidified floating organic drop microextraction combined with high performance liquid chromatography for the determination of carbamazepine in human plasma and urine samples Chin J Chromatogr 33 634-641
  • [9] Aguilar-Arteaga K(2004)Immersed solvent microextraction of phenol and chlorophenols from water samples followed by gas chromatography-mass spectrometry J Chromatogr A 1046 27-33
  • [10] Rodriguez JA(2014)Determination of triazole fungicides in liquid samples using ultrasound-assisted emulsification microextraction with solidification of floating organic droplet followed by high-performance liquid chromatography Food Anal Methods 7 1195-1203