Time-domain Analysis of Laboratory Experiments on the Transient Pressure Damping in a Leaky Polymeric Pipe

被引:0
作者
Caterina Capponi
Silvia Meniconi
Pedro J. Lee
Bruno Brunone
Marco Cifrodelli
机构
[1] The University of Perugia,Department of Civil and Environmental Engineering
[2] The University of Canterbury,Department of Civil and Natural Resources Engineering
来源
Water Resources Management | 2020年 / 34卷
关键词
Leak detection; Transient; Pressure damping; Pressurized pipes;
D O I
暂无
中图分类号
学科分类号
摘要
The pressure damping occurring in pressurized pipes with a leak during transients has been examined as a diagnostic tool – the so-called transient damping method (TDM) – mainly from the theoretical and numerical point of view. On the contrary, the experimental data are limited to few cases. As a consequence, there is a need of an extensive experimental analysis of the role played on the pressure damping by leak parameters (size, location and initial pressure). On the basis of the laboratory tests executed on a polymeric pipe, it is shown that, while the magnitude of the injected pressure wave does not affect the damping, the initial pressure, the leak size and location influence it plainly. Moreover, an experimental evidence is provided of the ambiguity in the time-domain of the transient pressure damping pointed out by numerical experiments. Precisely, it is demonstrated that different combinations of the leak parameters can lead to the same pressure damping. The obtained results indicate that the TDM can give a reliable assessment of the pipe status only if it is integrated with other diagnostic tools, such as the interpretation of the pressure signal during the first characteristic time of the pipe.
引用
收藏
页码:501 / 514
页数:13
相关论文
共 48 条
[1]  
Ayati A(2019)Statistical review of major standpoints in hydraulic transient-based leak detection Journal of Hydraulic Structures 5 1-26
[2]  
Haghighi A(1999)Transient test-based technique for leak detection in outfall pipes J Water Res Plan Man, ASCE 125 302-306
[3]  
Lee P(2017)Waterloss detection in water distribution networks using wavelet change-point detection Water Resour Manag, EWRA 31 979-994
[4]  
Brunone B(2010)Case studies of leak detection and location in water pipe systems by inverse transient analysis J Water Res Plan Man, ASCE 136 248-257
[5]  
Christodoulou SE(2019)Leakage estimation in water distribution network: effect of the shape and size cracks Water Resour Manag, EWRA 33 1167-1183
[6]  
Kourti E(2006)Experimental verification of the frequency response method for pipeline leak detection J Hydraul Res, IAHR 44 693-707
[7]  
Agathokleous A(1994)Inverse transient analysis in pipe networks J Hydraul Eng, ASCE 120 934-955
[8]  
Covas D(2019)Theoretical investigation of leak’s impact on normal modes of a water-filled pipe: small to large leak impedance J Hydraul Eng, ASCE 145 04019017-838
[9]  
Ramos H(1998)Pipeline leak detection by impulse response extraction J Fluids Eng, ASME 120 833-345
[10]  
De Marchis M(2011)Transient tests for locating and sizing illegal branches in pipe systems J Hydroinform, IWA 13 334-749