A systematic indoor air quality audit approach for public buildings

被引:0
|
作者
Ehsan Asadi
Manuel C. Gameiro da Silva
J. J. Costa
机构
[1] University of Coimbra,MIT
[2] University of Coimbra,Portugal Program, Department of Mechanical Engineering
来源
Environmental Monitoring and Assessment | 2013年 / 185卷
关键词
Indoor air quality (IAQ); Air exchange rate (AER); Indoor air pollutants; Metabolic CO;
D O I
暂无
中图分类号
学科分类号
摘要
Good indoor air quality (IAQ) in buildings provides a comfortable and healthy environment for the occupants to work, learn, study, etc. Therefore, it is important to ascertain the IAQ status in the buildings. This study is aimed to establish and demonstrate the comprehensive IAQ audit approach for public buildings, based on Portugal national laws. Four public buildings in Portugal are used to demonstrate the IAQ audit application. The systematic approach involves the measurement of physical parameters (temperature, relative humidity, and concentration of the suspended particulate matter), monitoring of the concentrations of selected chemical indicators [carbon dioxide (CO2), carbon monoxide, formaldehyde, ozone, and total volatile organic compounds], and the measurements of biological indicators (bacteria and fungi). In addition, air exchange rates are measured by the concentration decay method using metabolic CO2 as the tracer gas. The comprehensive audits indicated some situations of common IAQ problems in buildings, namely: (1) insufficient ventilation rate, (2) too high particle concentration; and (3) poor filtration effectiveness and hygienic conditions in most of the air handling units. Accordingly, a set of recommendations for the improvement of IAQ conditions were advised to the building owner/managers.
引用
收藏
页码:865 / 875
页数:10
相关论文
共 50 条
  • [41] Apply grey relating method to evaluate indoor air quality
    Han, J
    Zhang, JW
    Zhang, GQ
    BUILT ENVIRONMENT AND PUBLIC HEALTH, PROCEEDINGS, 2004, : 183 - 186
  • [42] Investigation of Indoor Air Quality inside Houses From UAE
    Bani Mfarrej, Manar Fawzi
    Qafisheh, Nida Ali
    Bahloul, Moez Mohamed
    AIR SOIL AND WATER RESEARCH, 2020, 13
  • [43] Indoor air quality in sports center: Assessment of gaseous pollutants
    Bralewska, Karolina
    Rogula-Kozlowska, Wioletta
    Bralewski, Adrian
    BUILDING AND ENVIRONMENT, 2022, 208
  • [44] Evaluation on four sampling schemes for assessing indoor air quality
    Wong, L. T.
    Mui, K. W.
    BUILDING AND ENVIRONMENT, 2007, 42 (03) : 1119 - 1125
  • [45] Indoor Air Quality Assessment Based ON Grey Classification Method
    Zhang Furen
    Deng Panpan
    Xu Pai
    2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 3910 - 3913
  • [46] An Investigation of Indoor Air Quality in a Recently Refurbished Educational Building
    McLeod, R. S.
    Mathew, M.
    Salman, D.
    Thomas, C. L. P.
    FRONTIERS IN BUILT ENVIRONMENT, 2022, 7
  • [47] Indoor air quality (IAQ) in Hong Kong service apartment
    Mui, K
    Chan, M
    Leung, C
    Lau, Y
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 2660 - 2664
  • [48] Evaluation of Effects of VOCs Released by MDF on Indoor Air Quality
    Jiang L.
    Zhao Z.
    Shen J.
    Meng J.
    Dong H.
    Linye Kexue/Scientia Silvae Sinicae, 2020, 56 (07): : 135 - 141
  • [49] Effect of Air Purifier Use in the Classrooms on Indoor Air Quality-Case Study
    Basinska, Malgorzata
    Michalkiewicz, Michal
    Ratajczak, Katarzyna
    ATMOSPHERE, 2021, 12 (12)
  • [50] Indoor air quality (IAQ), pollutants, their sources and methods of elimination
    Wang, JJ
    Xie, YB
    Yuan, FD
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 2542 - 2546