A systematic indoor air quality audit approach for public buildings

被引:0
|
作者
Ehsan Asadi
Manuel C. Gameiro da Silva
J. J. Costa
机构
[1] University of Coimbra,MIT
[2] University of Coimbra,Portugal Program, Department of Mechanical Engineering
来源
Environmental Monitoring and Assessment | 2013年 / 185卷
关键词
Indoor air quality (IAQ); Air exchange rate (AER); Indoor air pollutants; Metabolic CO;
D O I
暂无
中图分类号
学科分类号
摘要
Good indoor air quality (IAQ) in buildings provides a comfortable and healthy environment for the occupants to work, learn, study, etc. Therefore, it is important to ascertain the IAQ status in the buildings. This study is aimed to establish and demonstrate the comprehensive IAQ audit approach for public buildings, based on Portugal national laws. Four public buildings in Portugal are used to demonstrate the IAQ audit application. The systematic approach involves the measurement of physical parameters (temperature, relative humidity, and concentration of the suspended particulate matter), monitoring of the concentrations of selected chemical indicators [carbon dioxide (CO2), carbon monoxide, formaldehyde, ozone, and total volatile organic compounds], and the measurements of biological indicators (bacteria and fungi). In addition, air exchange rates are measured by the concentration decay method using metabolic CO2 as the tracer gas. The comprehensive audits indicated some situations of common IAQ problems in buildings, namely: (1) insufficient ventilation rate, (2) too high particle concentration; and (3) poor filtration effectiveness and hygienic conditions in most of the air handling units. Accordingly, a set of recommendations for the improvement of IAQ conditions were advised to the building owner/managers.
引用
收藏
页码:865 / 875
页数:10
相关论文
共 50 条
  • [31] Low-cost IoT-enabled indoor air quality monitoring systems: A systematic review
    Peixe, Joao
    Marques, Goncalo
    JOURNAL OF AMBIENT INTELLIGENCE AND SMART ENVIRONMENTS, 2024, 16 (02) : 167 - 180
  • [32] Revolutionizing indoor air quality monitoring through IoT innovations: a comprehensive systematic review and bibliometric analysis
    Tan H.
    Othman M.H.D.
    Kek H.Y.
    Chong W.T.
    Nyakuma B.B.
    Wahab R.A.
    Teck G.L.H.
    Wong K.Y.
    Environmental Science and Pollution Research, 2024, 31 (32) : 44463 - 44488
  • [33] Screening for indoor air quality of air-conditioned off ices
    Wong, L. T.
    Mui, K. W.
    Hui, P. S.
    INDOOR AND BUILT ENVIRONMENT, 2007, 16 (05) : 438 - 443
  • [34] Short Paper: Indoor Air Quality Assessments of Diverse Buildings in an Energy Conservation District from a Life Cycle Assessment Lens
    Rickenbacker, Harold J.
    Collinge, William O.
    Hasik, Vaclav
    Bilec, Melissa M.
    BUILDSYS'16: PROCEEDINGS OF THE 3RD ACM CONFERENCE ON SYSTEMS FOR ENERGY-EFFCIENT BUILT ENVIRONMENTS, 2016, : 207 - 210
  • [35] Indoor Air Quality in Passivhaus Dwellings: A Literature Review
    Moreno-Rangel, Alejandro
    Sharpe, Tim
    McGill, Grainne
    Musau, Filbert
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (13) : 1 - 16
  • [36] Indoor air quality control for green hotels in Beijing
    Huang, ZH
    Kang, FY
    Yang, JB
    Zhu, JT
    Lu, YQ
    Fan, X
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 3293 - 3297
  • [37] Particle dispersion for indoor air quality control considering air change approach: A novel accelerated CFD-DNN prediction
    Kek, Hong Yee
    Bazgir, Adib
    Tan, Huiyi
    Lee, Chew Tin
    Hong, Taehoon
    Othman, Mohd Hafiz Dzarfan
    Van Fan, Yee
    Zhang, Yuwen
    Wong, Keng Yinn
    ENERGY AND BUILDINGS, 2024, 306
  • [38] Assessing Indoor Air Quality Using Chemometric Models
    Azid, Azman
    Amran, Mohammad Azizi
    Samsudin, Mohd Saiful
    Abd Rani, Nurul Latiffah
    Khalit, Saiful Iskandar
    Gasim, Muhammad Barzani
    Yunus, Kamaruzzaman
    Saudi, Ahmad Shakir Mohd
    Amin, Siti Noor Syuhada Muhammad
    Yusof, Ku Mohd Kalkausar Ku
    POLISH JOURNAL OF ENVIRONMENTAL STUDIES, 2018, 27 (06): : 2443 - 2450
  • [39] Indoor air quality benchmarks of 'Grade A' offices in HongKong
    Hui, P. S.
    Wong, L. T.
    Mui, K. W.
    FIRST INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT, PROCEEDINGS VOLS 1-3, 2008, : 685 - 690
  • [40] The perception of air purifiers on indoor air quality: effective or human herd behavior?
    Ifta Irodatul Utami
    Wishnu Agung Baroto
    City and Built Environment, 3 (1):