Good indoor air quality (IAQ) in buildings provides a comfortable and healthy environment for the occupants to work, learn, study, etc. Therefore, it is important to ascertain the IAQ status in the buildings. This study is aimed to establish and demonstrate the comprehensive IAQ audit approach for public buildings, based on Portugal national laws. Four public buildings in Portugal are used to demonstrate the IAQ audit application. The systematic approach involves the measurement of physical parameters (temperature, relative humidity, and concentration of the suspended particulate matter), monitoring of the concentrations of selected chemical indicators [carbon dioxide (CO2), carbon monoxide, formaldehyde, ozone, and total volatile organic compounds], and the measurements of biological indicators (bacteria and fungi). In addition, air exchange rates are measured by the concentration decay method using metabolic CO2 as the tracer gas. The comprehensive audits indicated some situations of common IAQ problems in buildings, namely: (1) insufficient ventilation rate, (2) too high particle concentration; and (3) poor filtration effectiveness and hygienic conditions in most of the air handling units. Accordingly, a set of recommendations for the improvement of IAQ conditions were advised to the building owner/managers.
引用
收藏
页码:865 / 875
页数:10
相关论文
共 50 条
  • [1] A systematic indoor air quality audit approach for public buildings
    Asadi, Ehsan
    Gameiro da Silva, Manuel C.
    Costa, J. J.
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2013, 185 (01) : 865 - 875
  • [2] Indoor air quality audit implementation in a hotel building in Portugal
    Asadi, Ehsan
    Costa, J. J.
    da Silva, Manuel Gameiro
    BUILDING AND ENVIRONMENT, 2011, 46 (08) : 1617 - 1623
  • [3] Improving the Indoor Air Quality in Nursery Buildings in United Arab Emirates
    Arar, Mohammad
    Jung, Chuloh
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (22)
  • [4] A finish material management system for indoor air quality of apartment buildings (FinIAQ)
    Lee, Sungho
    Kwon, Gideoc
    Joo, Jinkyu
    Kim, Jeong Tai
    Kim, Sunkuk
    ENERGY AND BUILDINGS, 2012, 46 : 68 - 79
  • [5] Taking the “leed” in indoor air quality: Does certification result in healthier buildings?
    Phillips H.
    Handy R.
    Sleeth D.
    Thiese M.S.
    Schaefer C.
    Stubbs J.
    Journal of Green Building, 1600, 15 (03): : 55 - 66
  • [6] TAKING THE "LEED" IN INDOOR AIR QUALITY: DOES CERTIFICATION RESULT IN HEALTHIER BUILDINGS?
    Phillips, Hannah
    Handy, Rod
    Sleeth, Darrah
    Thiese, Matthew S.
    Schaefer, Camie
    Stubbs, James
    JOURNAL OF GREEN BUILDING, 2020, 15 (03): : 55 - 66
  • [7] Experimental Study of Indoor Air Quality in Educational Buildings: A Spanish Case Study
    Matilla, Alberto Leal
    Velilla, Jorge Pablo Diaz
    Zaragoza-Benzal, Alicia
    Ferrandez, Daniel
    Santos, Paulo
    BUILDINGS, 2023, 13 (11)
  • [8] Development and application of an integrated indoor air quality audit to an international hotel building in Taiwan
    Kuo, Nae-Wen
    Chiang, Hsin-Chen
    Chiang, Che-Ming
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2008, 147 (1-3) : 139 - 147
  • [9] Development and application of an integrated indoor air quality audit to an international hotel building in Taiwan
    Nae-Wen Kuo
    Hsin-Chen Chiang
    Che-Ming Chiang
    Environmental Monitoring and Assessment, 2008, 147 : 139 - 147
  • [10] Natural ventilation and indoor air quality in educational buildings: experimental assessment and improvement strategies
    Ricardo M. S. F. Almeida
    Manuel Pinto
    Paulo G. Pinho
    Luís T. de Lemos
    Energy Efficiency, 2017, 10 : 839 - 854