Analysis and comparison of monofocal, extended depth of focus and trifocal intraocular lens profiles

被引:0
作者
Juan J. Miret
Vicente J. Camps
Celia García
Maria T. Caballero
Juan M. Gonzalez-Leal
机构
[1] University of Alicante,Group of Optics and Visual Perception, Department of Optics, Pharmacology and Anatomy
[2] University of Cadiz,Department of Condensed Matter Physics, Faculty of Sciences
来源
Scientific Reports | / 12卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
To test the feasibility of using profilometers to extract information about IOL surfaces design. A standard monofocal IOL (Tecnis 1), a monofocal IOL that provided some depth of focus (Eyhance), an extended depth of focus IOL based on refractive optics (Mini Well) and a trifocal IOL based on diffractive optics were used in this study (Tecnis Synergy). The surface topography of the IOLs was measured by using a multimode optical profilometer. Posterior surface of Tecnis 1 IOL was spherical and the anterior surface aspherical. In the Eyhance IOL, posterior surface was spherical and anterior surface did not fit to any of our reference surfaces, indicating a higher order aspheric surface design. In the Mini Well Ready IOL, a best-fit sphere surface was obtained for the second surface and a high order aspherical surface design was deduced for the first surface. The anterior surface of the Synergy IOL was aspherical and the base curve of the diffractive structure fitted very well to a spherical surface. To consider an aspheric surface as possible best-fit surface provided more information than if only best-fit spherical surface was considered. The high order aspheric surface designs employed in the IOLs studied presented differences, regarding best-fit asphere surface, higher than 1 micron. These differences were correlated with the generation of spherical aberration complex profiles (with Zernike terms higher than 4th order) and with the production of distinct amounts of depth of focus. This method was also useful to deduce the base curve of diffractive surfaces.
引用
收藏
相关论文
共 94 条
[1]  
Vega F(2021)Optical design and performance of a trifocal sinusoidal diffractive intraocular lens Biomed. Opt. Express 12 3338-3351
[2]  
Valentino M(2011)Design and qualification of a diffractive trifocal optical profile for intraocular lenses J. Cataract Refract. Surg. 37 2060-2067
[3]  
Rigato F(2017)In vitro aberrometric assessment of a multifocal intraocular lens and two extended depth of focus IOLs J. Ophthalmol. 2017 7095734-227
[4]  
Millan MS(2018)Simulation of the effect of different presbyopia-correcting intraocular lenses with eyes with previous laser refractive surgery J. Refract. Surg. 34 222-5256
[5]  
Gatinel D(2010)Comparison of the efficiency, MTF and chromatic properties of four diffractive bifocal intraocular lens designs Opt. Express 18 5245-46
[6]  
Pagnoulle C(2012)Optical and visual quality comparison of implantable Collamer lens and laser in situ keratomileusis for myopia using an adaptive optics visual simulator Eur. J. Ophthalmol. 23 39-906
[7]  
Houbrechts Y(2020)New method to improve the quality of vision in cataractous keratoconus eye Sci Rep 10 20049-916
[8]  
Gobin L(2015)Application of nanoimprinting technique for fabrication of trifocal diffractive lens with sine-like radial profile J. Biomed. Opt. 20 25008-632
[9]  
Camps VJ(2018)Fractal-structured multifocal intraocular lens PLoS One 13 e0200197-1808
[10]  
Tolosa A(2020)Surface profiles of new-generation IOLs with improved intermediate vision J Cataract Refract. Surg. 46 902-262