Comparison of organ cultured precut corneas versus surgeon-cut corneas for Descemet’s stripping automated endothelial keratoplasty

被引:0
作者
Suganiah Ragunathan
Anders Ivarsen
Kim Nielsen
Jesper Hjortdal
机构
[1] Aarhus University Hospital,Department of Ophthalmology
来源
Cell and Tissue Banking | 2014年 / 15卷
关键词
Descemet stripping endothelial keratoplasty; Corneal transplantation; Eye banks; Tissue donors; Organ culture;
D O I
暂无
中图分类号
学科分类号
摘要
To compare precut and surgeon-cut organ cultured donor corneas for DSAEK. A total of 119 consecutive eyes treated with DSAEK were retrospectically identified. 65 grafts were cut by the surgeon (Moria, ALTK System) prior to DSAEK and 54 grafts were precut by laboratory technicians from the Danish Eye Bank (Horizon single-use system). 1 year after surgery, tomographic images were obtained with the Pentacam HR. Endothelial cell density (ECD) and best-corrected visual acuity (BCVA) was determined. Graft thickness and graft asymmetry was evaluated in the centre and 1 mm from the edge of the graft in 6 semi-meridians. 1 year after surgery, the ECD loss was similar in the two groups, averaging 25.9 ± 14 % in surgeon-cut, and 22.9 ± 17 % in precut group (p = 0.33). Mean central graft thickness was 172 ± 6 μm in surgeon-cut grafts and 182 ± 6 μm in precut grafts (p = 0.30). BCVA was similar in surgeon-cut and precut corneas; being 0.25 ± 0.02 logMAR and 0.24 ± 0.02 logMAR, respectively (p = 0.59). The graft asymmetry index was 1.48 ± 0.02 for surgeon-cut and 1.44 ± 0.02 for precut grafts. There were no significant differences in complications rate in both groups. No correlations between BCVA and central graft thickness or graft asymmetry index in both groups were observed. Organ cultured precut donor corneas are comparable with surgeon-cut grafts with respect to ECD, graft thickness and asymmetry, and postoperative complication rate.
引用
收藏
页码:573 / 578
页数:5
相关论文
共 57 条
  • [1] De Sanctis U(2011)Corneal power after DSAEK using microkeratome-prepared tissues Optom Vis Sci 88 697-702
  • [2] Angeloni M(2013)Effects of graft thickness and asymmetry on visual gain and aberrations after descemet stripping automated endothelial keratoplasty JAMA Ophthalmol 11 1-8
  • [3] Zilio C(1999)Corneal transplantation with donor tissue kept in organ culture for 7 weeks Acta Ophthalmol Scand 77 277-278
  • [4] Dickman MM(2012)Corneal topographic analysis by 3-dimensional anterior segment optical coherence tomography after endothelial keratoplasty Invest Ophthalmol Vis Sci 53 3286-3295
  • [5] Cheng YY(2012)Inverse cutting of posterior lamellar corneal grafts by a femtosecond laser Open Ophthalmol J 6 19-22
  • [6] Berendschot TT(2012)Histopathological evaluation of anterior lamellar corneal tissue-on/-off storage conditions on DSAEK donor tissue after storage in organ culture Curr Eye Res 37 155-158
  • [7] Ehlers H(2008)Eye bank survey of surgeons using precut donor tissue for descemet stripping automated endothelial keratoplasty Cornea 27 634-639
  • [8] Ehlers N(2011)Comparison of central corneal graft thickness to visual acuity outcomes in endothelial keratoplasty Cornea 30 388-391
  • [9] Hjortdal JO(2009)A clinicopathologic series of primary graft failure after Descemet’s stripping and automated endothelial keratoplasty Ophthalmology 116 609-614
  • [10] Higashiura R(2008)Eye bank issues: II. Preservation techniques: warm versus cold storage Int Ophthalmol 28 155-163