Bioabsorbable interference screw versus bioabsorbable cross pins: influence of femoral graft fixation on the clinical outcome after ACL reconstruction

被引:0
作者
Stephan Frosch
Anne Rittstieg
Peter Balcarek
Tim Alexander Walde
Jan P. Schüttrumpf
Martin M. Wachowski
Klaus M. Stürmer
Karl-Heinz Frosch
机构
[1] Medical University of Göttingen,Department of Trauma Surgery, Plastic and Reconstructive Surgery
[2] Asklepios Clinic St. Georg,Department of Trauma and Reconstructive Surgery
来源
Knee Surgery, Sports Traumatology, Arthroscopy | 2012年 / 20卷
关键词
Milagro screw; Interference screw; Cross pins; ACL reconstruction; Postoperative outcome;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:2251 / 2256
页数:5
相关论文
共 50 条
  • [21] Close-looped graft suturing improves mechanical properties of interference screw fixation in ACL reconstruction
    María Prado
    Belén Martín-Castilla
    Alejandro Espejo-Reina
    José Miguel Serrano-Fernández
    Ana Pérez-Blanca
    Francisco Ezquerro
    Knee Surgery, Sports Traumatology, Arthroscopy, 2013, 21 : 476 - 484
  • [22] Close-looped graft suturing improves mechanical properties of interference screw fixation in ACL reconstruction
    Prado, Maria
    Martin-Castilla, Belen
    Espejo-Reina, Alejandro
    Miguel Serrano-Fernandez, Jose
    Perez-Blanca, Ana
    Ezquerro, Francisco
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2013, 21 (02) : 476 - 484
  • [23] Clinical and radiological comparison of bioactive glass and poly-L-lactic acid/hydroxyapatite bioabsorbable interference screws for tibial graft fixation in anterior cruciate ligament reconstruction
    Veizi, Enejd
    Alkan, Hilmi
    Cay, Nurdan
    Sahin, Ali
    Cepni, Sahin
    Tecimel, Osman
    Firat, Ahmet
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2022, 108 (03)
  • [24] Resorbable screw and sheath versus resorbable interference screw and staples for ACL reconstruction: a comparison of two tibial fixation methods
    Christian Carulli
    Fabrizio Matassi
    Stefano Soderi
    Luigi Sirleo
    Giovanni Munz
    Massimo Innocenti
    Knee Surgery, Sports Traumatology, Arthroscopy, 2017, 25 : 1264 - 1271
  • [25] No difference in clinical results between femoral transfixation and bio-interference screw fixation in hamstring tendon ACL reconstruction - A preliminary study
    Capuano, Luca
    Hardy, Philippe
    Longo, Umile Giuseppe
    Denaro, Vincenzo
    Maffulli, Nicola
    KNEE, 2008, 15 (03) : 174 - 179
  • [26] Evaluation of Isokinetic Knee Strengths after ACL Reconstruction with Quadrupled Semitendinosus Suspensory Femoral and Tibial Fixation versus Four-Strand Semitendinosus and Gracilis Suspensory Femoral and Tibial Screw Fixation
    Cerci, Mehmet Halis
    Yilmaz, Ali Kerim
    Kehribar, Lokman
    Surucu, Serkan
    Aydin, Mahmud
    Mahirogullari, Mahir
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (12)
  • [27] Resorbable screw and sheath versus resorbable interference screw and staples for ACL reconstruction: a comparison of two tibial fixation methods
    Carulli, Christian
    Matassi, Fabrizio
    Soderi, Stefano
    Sirleo, Luigi
    Munz, Giovanni
    Innocenti, Massimo
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2017, 25 (04) : 1264 - 1271
  • [28] Arthroscopic reconstruction of the ACL with double-looped semitendinosus and gracilis tendons and fixation with bioabsorbable interference screws. Medium-term results
    Comba, D
    Sandrucci, G
    Graziano, E
    Regis, G
    Cenna, E
    JOURNAL OF SPORTS TRAUMATOLOGY AND RELATED RESEARCH, 1999, 21 (03): : 145 - 154
  • [29] Biomechanical Comparison of a Novel Tibial Fixation Technique Versus Interference Screw Fixation for ACL Reconstruction Using Soft Tissue Grafts
    Sun, Tinghan
    Zhang, Hangzhou
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2021, 9 (08)
  • [30] Mechanical Evaluation of Bone-Patellar Tendon-Bone Graft Fixation to the Tibia in ACL Reconstruction: Bone Plug Tensioning and Fixation System versus Interference Screw
    Iuchi, Ryo
    Shino, Konsei
    Mae, Tatsuo
    Yamakawa, Satoshi
    Nakata, Ken
    JOURNAL OF KNEE SURGERY, 2024, 37 (13) : 894 - 901