Reproducibility of pulse wave velocity measurements with phase contrast magnetic resonance and applanation tonometry

被引:0
|
作者
Jonathan D. Suever
John Oshinski
Enrique Rojas-Campos
David Huneycutt
Francesca Cardarelli
Arthur E. Stillman
Paolo Raggi
机构
[1] Emory University and Georgia Institute of Technology,Wallace H. Coulter Department of Biomedical Engineering
[2] Emory University School of Medicine,Department of Radiology and Imaging Sciences
[3] Emory University School of Medicine,Department of Medicine, Division of Cardiology
来源
The International Journal of Cardiovascular Imaging | 2012年 / 28卷
关键词
Pulse wave velocity; Applanation tonometry; Cross-correlation; Phase contrast magnetic resonance;
D O I
暂无
中图分类号
学科分类号
摘要
Increased aortic pulse wave velocity (PWV) results from loss of arterial compliance and is associated with unfavorable outcomes. Applanation tonometry (AT) is the most frequently applied method to assess PWV and deduce aortic compliance. The goal of this study was to compare the reproducibility of PWV measurements obtained with: (1) cross-correlation analysis of phase contrast magnetic resonance (PCMR) velocity data, and (2) applanation tonometry (AT). PWV was measured twice with each modality in 13 normal young volunteers (controls) and 9 older patients who had undergone a CT exam to evaluate coronary artery calcium. The coefficient of variation (CoV) between measurements was computed for each modality. There was no significant difference in PWV values obtained with AT and PCMR in controls or patients. The inter-scan reproducibility of PCMR was superior to AT in the controls (CoV: 3.4 ± 2.3% vs. 6.3 ± 4.0%, P = 0.03) but not in the older patients (7.4 ± 8.0% vs. 9.9 ± 9.6%, P = 0.32). PWV values were higher in patients than controls (5.6 ± 1.2 vs. 9.7 ± 2.8, P = 0.002). PCMR and AT yielded similar values for PWV in patients and volunteers. PCMR showed a superior reproducibility in young subjects but not in older patients.
引用
收藏
页码:1141 / 1146
页数:5
相关论文
共 50 条
  • [41] Repeatability of Different Segmental Pulse Wave Velocity Measurements
    Papaioannou, Theodore G.
    Stamatelopoulos, Kimon
    Tousoulis, Dimitrios
    AMERICAN JOURNAL OF HYPERTENSION, 2016, 29 (07) : 889 - 889
  • [42] Assessement of repeatability of aortic pulse wave velocity measurements
    Strozecki, Pawel
    Manitius, Jacek
    ARTERIAL HYPERTENSION, 2009, 13 (05): : 327 - 335
  • [43] COMPARISON OF ECHOTRACKING AND MAGNETIC RESONANCE ASSESSMENT OF ABDOMINAL AORTA DISTENSIBILITY AND RELATIONSHIPS WITH PULSE WAVE VELOCITY
    Giannattasio, Cristina
    Cesana, Francesca
    Maestroni, Silvia
    Salvioni, Alessandra
    Maloberti, Alessandro
    Nava, Stefano
    Cairo, Matteo
    Madotto, Fabiana
    Zerboni, Filippo
    Sironi, Sandro
    Grassi, Guido
    Mancia, Giuseppe
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2011, 37 (12): : 1970 - 1976
  • [44] Regional assessment of carotid artery pulse wave velocity using compressed sensing accelerated high temporal resolution 2D CINE phase contrast cardiovascular magnetic resonance
    Eva S. Peper
    Gustav J. Strijkers
    Katja Gazzola
    Wouter V. Potters
    Abdallah G. Motaal
    Ilse K. Luirink
    Barbara A. Hutten
    Albert Wiegman
    Pim van Ooij
    Bert-Jan H. van den Born
    Aart J. Nederveen
    Bram F. Coolen
    Journal of Cardiovascular Magnetic Resonance, 20
  • [45] Indices of cardiovascular function derived from peripheral pulse wave analysis using radial applanation tonometry: a measurement repeatability study
    Crilly, Mike
    Coch, Christoph
    Bruce, Margaret
    Clark, Hazel
    Williams, David
    VASCULAR MEDICINE, 2007, 12 (03) : 189 - 197
  • [46] Regional assessment of carotid artery pulse wave velocity using compressed sensing accelerated high temporal resolution 2D CINE phase contrast cardiovascular magnetic resonance
    Peper, Eva S.
    Strijkers, Gustav J.
    Gazzola, Katja
    Potters, Wouter V.
    Motaal, Abdallah G.
    Luirink, Ilse K.
    Hutten, Barbara A.
    Wiegman, Albert
    van Ooij, Pim
    van den Born, Bert-Jan H.
    Nederveen, Aart J.
    Coolen, Bram F.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2018, 20
  • [47] Repeatability of central aortic blood pressures measured noninvasively using radial artery applanation tonometry and peripheral pulse wave analysis
    Crilly, Mike
    Coch, Christoph
    Bruce, Margaret
    Clark, Hazel
    Williams, David
    BLOOD PRESSURE, 2007, 16 (04) : 262 - 269
  • [48] Ageing, hypertension and aortic valve stenosis-Understanding the series circuit using cardiac magnetic resonance and applanation tonometry
    Hungerford, S. L.
    Adji, A., I
    Bart, N. K.
    Lin, L.
    Song, N.
    Jabbour, A.
    O'Rourke, M. F.
    Hayward, C. S.
    Muller, D. W. M.
    INTERNATIONAL JOURNAL CARDIOLOGY HYPERTENSION, 2021, 9
  • [49] 154 Aortic pulse wave velocity assessed with velocity-encoded MRI: a validation and reproducibility study
    Heynric B Grotenhuis
    Jos JM Westenberg
    Paul Steendijk
    Theodorus AM Kaandorp
    Wouter J Jukema
    Jeroen J Bax
    Johan HC Reiber
    Albert de Roos
    Journal of Cardiovascular Magnetic Resonance, 10 (Suppl 1)
  • [50] Brachial-Ankle Pulse Wave Velocity as a Screen for Arterial Stiffness: A Comparison with Cardiac Magnetic Resonance
    Kim, Eun Kyoung
    Chang, Sung-A
    Jang, Shin Yi
    Choi, Ki Hong
    Huh, Eun Hee
    Kim, Jung Hyun
    Kim, Sung Mok
    Choe, Yeon Hyeon
    Kim, Duk-Kyung
    YONSEI MEDICAL JOURNAL, 2015, 56 (03) : 617 - 624