Reproducibility of pulse wave velocity measurements with phase contrast magnetic resonance and applanation tonometry

被引:0
|
作者
Jonathan D. Suever
John Oshinski
Enrique Rojas-Campos
David Huneycutt
Francesca Cardarelli
Arthur E. Stillman
Paolo Raggi
机构
[1] Emory University and Georgia Institute of Technology,Wallace H. Coulter Department of Biomedical Engineering
[2] Emory University School of Medicine,Department of Radiology and Imaging Sciences
[3] Emory University School of Medicine,Department of Medicine, Division of Cardiology
来源
The International Journal of Cardiovascular Imaging | 2012年 / 28卷
关键词
Pulse wave velocity; Applanation tonometry; Cross-correlation; Phase contrast magnetic resonance;
D O I
暂无
中图分类号
学科分类号
摘要
Increased aortic pulse wave velocity (PWV) results from loss of arterial compliance and is associated with unfavorable outcomes. Applanation tonometry (AT) is the most frequently applied method to assess PWV and deduce aortic compliance. The goal of this study was to compare the reproducibility of PWV measurements obtained with: (1) cross-correlation analysis of phase contrast magnetic resonance (PCMR) velocity data, and (2) applanation tonometry (AT). PWV was measured twice with each modality in 13 normal young volunteers (controls) and 9 older patients who had undergone a CT exam to evaluate coronary artery calcium. The coefficient of variation (CoV) between measurements was computed for each modality. There was no significant difference in PWV values obtained with AT and PCMR in controls or patients. The inter-scan reproducibility of PCMR was superior to AT in the controls (CoV: 3.4 ± 2.3% vs. 6.3 ± 4.0%, P = 0.03) but not in the older patients (7.4 ± 8.0% vs. 9.9 ± 9.6%, P = 0.32). PWV values were higher in patients than controls (5.6 ± 1.2 vs. 9.7 ± 2.8, P = 0.002). PCMR and AT yielded similar values for PWV in patients and volunteers. PCMR showed a superior reproducibility in young subjects but not in older patients.
引用
收藏
页码:1141 / 1146
页数:5
相关论文
共 50 条
  • [21] Measurement of pulse wave velocity using magnetic resonance imaging
    Gang, G
    Mark, P
    Cockshott, P
    Foster, J
    Martin, T
    Blyth, K
    Steedman, T
    Elliott, A
    Dargie, H
    Groenning, B
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 3684 - 3687
  • [22] Pulse Wave Velocity Measurements by Magnetic Resonance Imaging in Neonates and Adolescents: Methodological Aspects and Their Clinical Implications
    Simon Lundström
    Jonas Liefke
    Einar Heiberg
    Erik Hedström
    Pediatric Cardiology, 2022, 43 : 1631 - 1644
  • [23] Pulse Wave Velocity Measurements by Magnetic Resonance Imaging in Neonates and Adolescents: Methodological Aspects and Their Clinical Implications
    Lundstrom, Simon
    Liefke, Jonas
    Heiberg, Einar
    Hedstrom, Erik
    PEDIATRIC CARDIOLOGY, 2022, 43 (07) : 1631 - 1644
  • [24] Measurement of pulse wave velocity using pulse wave Doppler ultrasound: Comparison with arterial tonometry
    Jiang, Benyu
    Liu, Baoming
    McNeill, Karen L.
    Chowienczyk, Philip J.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2008, 34 (03): : 509 - 512
  • [25] Reproducibility of pulse wave velocity and augmentation index measured by pulse wave analysis
    Wilkinson, IB
    Fuchs, SA
    Jansen, IM
    Spratt, JC
    Murray, GD
    Cockcroft, JR
    Webb, DJ
    JOURNAL OF HYPERTENSION, 1998, 16 (12) : 2079 - 2084
  • [26] Aortic pulse wave velocity in obesity as assessed by magnetic resonance imaging
    Oliver J Rider
    Upasana Tayal
    Jane M Francis
    Monique Robinson
    James P Byrne
    Kieran Clarke
    Stefan Neubauer
    Journal of Cardiovascular Magnetic Resonance, 11 (Suppl 1)
  • [27] Pulse wave velocity in real-time cardiac magnetic resonance
    Martin Fasshauer
    Johannes T Kowallick
    Arun Joseph
    Christina Unterberg-Buchwald
    Klaus-Dietmar Merboldt
    Michael Steinmetz
    Jan M Sohns
    Wieland Staab
    Andreas Schuster
    Dirk Voit
    Sebastian Schaetz
    Shoun Zhang
    Jens Frahm
    Joachim Lotz
    Journal of Cardiovascular Magnetic Resonance, 16 (Suppl 1)
  • [28] Noninvasive evaluation of varying pulse pressures in vivo using brachial sphymomanometry, applanation tonometry, and Pulse Wave Ultrasound Manometry
    Li, Ronny X.
    Ip, Ada
    Sanz-Miralles, Elena
    Konofagou, Elisa E.
    ARTERY RESEARCH, 2017, 18 : 22 - 28
  • [29] Noninvasive evaluation of varying pulse pressures in vivo using brachial sphymomanometry, applanation tonometry, and Pulse Wave Ultrasound Manometry
    Ronny X. Li
    Ada Ip
    Elena Sanz-Miralles
    Elisa E. Konofagou
    Artery Research, 2017, 18 : 22 - 28
  • [30] Accurate method for measuring arterial pulse wave velocity by cardiovascular magnetic resonance
    El-Sayed Ibrahim
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)