Reproducibility of pulse wave velocity measurements with phase contrast magnetic resonance and applanation tonometry

被引:0
|
作者
Jonathan D. Suever
John Oshinski
Enrique Rojas-Campos
David Huneycutt
Francesca Cardarelli
Arthur E. Stillman
Paolo Raggi
机构
[1] Emory University and Georgia Institute of Technology,Wallace H. Coulter Department of Biomedical Engineering
[2] Emory University School of Medicine,Department of Radiology and Imaging Sciences
[3] Emory University School of Medicine,Department of Medicine, Division of Cardiology
来源
The International Journal of Cardiovascular Imaging | 2012年 / 28卷
关键词
Pulse wave velocity; Applanation tonometry; Cross-correlation; Phase contrast magnetic resonance;
D O I
暂无
中图分类号
学科分类号
摘要
Increased aortic pulse wave velocity (PWV) results from loss of arterial compliance and is associated with unfavorable outcomes. Applanation tonometry (AT) is the most frequently applied method to assess PWV and deduce aortic compliance. The goal of this study was to compare the reproducibility of PWV measurements obtained with: (1) cross-correlation analysis of phase contrast magnetic resonance (PCMR) velocity data, and (2) applanation tonometry (AT). PWV was measured twice with each modality in 13 normal young volunteers (controls) and 9 older patients who had undergone a CT exam to evaluate coronary artery calcium. The coefficient of variation (CoV) between measurements was computed for each modality. There was no significant difference in PWV values obtained with AT and PCMR in controls or patients. The inter-scan reproducibility of PCMR was superior to AT in the controls (CoV: 3.4 ± 2.3% vs. 6.3 ± 4.0%, P = 0.03) but not in the older patients (7.4 ± 8.0% vs. 9.9 ± 9.6%, P = 0.32). PWV values were higher in patients than controls (5.6 ± 1.2 vs. 9.7 ± 2.8, P = 0.002). PCMR and AT yielded similar values for PWV in patients and volunteers. PCMR showed a superior reproducibility in young subjects but not in older patients.
引用
收藏
页码:1141 / 1146
页数:5
相关论文
共 50 条
  • [1] Reproducibility of pulse wave velocity measurements with phase contrast magnetic resonance and applanation tonometry
    Suever, Jonathan D.
    Oshinski, John
    Rojas-Campos, Enrique
    Huneycutt, David
    Cardarelli, Francesca
    Stillman, Arthur E.
    Raggi, Paolo
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (05): : 1141 - 1146
  • [2] Reproducibility of aortic pulse wave velocity measurements obtained with Phase Contrast Magnetic Resonance (PCMR) and applanation tonometry
    Jonathan Suever
    David Huneycutt
    Enrique Rojas-Campos
    Francesca Cardarelli
    Amol Pedneker
    Sam Fielden
    Arthur Stillman
    Paolo Raggi
    John Oshinski
    Journal of Cardiovascular Magnetic Resonance, 11 (Suppl 1)
  • [3] Required temporal resolution for accurate thoracic aortic pulse wave velocity measurements by phase-contrast magnetic resonance imaging and comparison with clinical standard applanation tonometry
    Dorniak, Karolina
    Heiberg, Einar
    Hellmann, Marcin
    Rawicz-Zegrzda, Dorota
    Wesierska, Maria
    Galaska, Rafal
    Sabisz, Agnieszka
    Szurowska, Edyta
    Dudziak, Maria
    Hedstrom, Erik
    BMC CARDIOVASCULAR DISORDERS, 2016, 16
  • [4] Required temporal resolution for accurate thoracic aortic pulse wave velocity measurements by phase-contrast magnetic resonance imaging and comparison with clinical standard applanation tonometry
    Karolina Dorniak
    Einar Heiberg
    Marcin Hellmann
    Dorota Rawicz-Zegrzda
    Maria Wesierska
    Rafal Galaska
    Agnieszka Sabisz
    Edyta Szurowska
    Maria Dudziak
    Erik Hedström
    BMC Cardiovascular Disorders, 16
  • [5] 2127 Validation of cardiovascular magnetic resonance aortic distensibility with applanation tonometry pulse wave velocity
    Adam J Nelson
    Angelo Carbone
    Stephen G Worthley
    Cynthia Piantadosi
    Sarah A Hope
    James D Cameron
    Ian T Meredith
    Matthew I Worthley
    Journal of Cardiovascular Magnetic Resonance, 10 (Suppl 1)
  • [6] Aortic pulse wave velocity measured by pulse wave imaging (PWI): A comparison with applanation tonometry
    Vappou J.
    Luo J.
    Okajima K.
    Di Tullio M.
    Konofagou E.
    Artery Research, 2011, 5 (2) : 65 - 71
  • [7] A novel tool for phase contrast MR-derived pulse wave velocity measurement - validation against applanation tonometry and phantom studies
    Karolina Dorniak
    Marcin Hellmann
    Dorota Rawicz-Zegrzda
    Maria Wesierska
    Agnieszka Sabisz
    Edyta Szurowska
    Maria Dudziak
    Einar Heiberg
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [8] Pulse Wave Analysis by Applanation Tonometry for the Measurement of Arterial Stiffness
    Doupis, John
    Papanas, Nikolaos
    Cohen, Alison
    McFarlan, Lyndsay
    Horton, Edward
    OPEN CARDIOVASCULAR MEDICINE JOURNAL, 2016, 10 : 188 - 195
  • [9] Diurnal variation of pulse wave velocity assessed non-invasively by applanation tonometry in young healthy men
    Bodlaj, Gerd
    Berg, Joerg
    Biesenbach, Georg
    YONSEI MEDICAL JOURNAL, 2007, 48 (04) : 665 - 670
  • [10] Measurement of pulse wave velocity in normal ageing: comparison of Vicorder and magnetic resonance phase contrast imaging
    Jehill D. Parikh
    Kieren G. Hollingsworth
    Vijay Kunadian
    Andrew Blamire
    Guy A. MacGowan
    BMC Cardiovascular Disorders, 16