共 50 条
Comparison of a laboratory and a production coating spray gun with respect to scale-up
被引:0
|作者:
Ronny Mueller
Peter Kleinebudde
机构:
[1] Heinrich-Heine-University,Institute of Pharmaceutics and Biopharmaceutics
来源:
AAPS PharmSciTech
|
/
8卷
关键词:
Atomization;
film coating;
spray gun;
scale-up;
design of experiments;
D O I:
暂无
中图分类号:
学科分类号:
摘要:
A laboratory spray gun and a production spray gun were investigated in a scale-up study. Two Schlick spray guns, which are equipped with a new antibearding cap, were used in this study. The influence of the atomization air pressure, spray gun-to tablet bed distance, polymer solution viscosity, and spray rate were analyzed in a statistical design of experiments. The 2 spray guns were compared with respect to the spray width and height, droplet size, droplet velocity, and spray density. The droplet size, velocity, and spray density were measured with a Phase Doppler Particle Analyzer.