Properties of Multilayered Metallic Coatings Deposited on Carbon Fiber-Reinforced Polymers (CFRPs) through Electrochemical and Cold Spray Processes

被引:0
作者
Panteha Fallah
Sima A. Alidokht
Phuong Vo
Richard R. Chromik
André McDonald
Stephen Yue
机构
[1] McGill University,Department of Mining and Materials Engineering
[2] Memorial University of Newfoundland,Department of Mechanical and Mechatronics Engineering, Faculty of Engineering and Applied Science
[3] National Research Council Canada,Department of Mechanical Engineering
[4] University of Alberta,undefined
来源
Journal of Thermal Spray Technology | 2023年 / 32卷
关键词
adhesive failure; cohesive failure; grain size; microstructure; scratch adhesion testing; tensile adhesion bond strength;
D O I
暂无
中图分类号
学科分类号
摘要
Previous studies have shown that copper (Cu) may be cold spray deposited on epoxy carbon fiber-reinforced polymers (CFRPs) if an interlayer Cu of electroplated on an electroless nickel (Ni) coating is present prior to cold spraying. In this present study, the tensile adhesion bond strength of these multilayered metallic coatings was measured in accordance with ASTM Standard C-633-13. Fractured surfaces after tensile adhesion testing were examined by scanning electron microscopy (SEM) and optical microscopy (OM). Scratch adhesion testing from the polished cross sections of the multilayered coatings was also performed to compare the results with those obtained from the tensile adhesion testing. The microstructure of the cold-sprayed and electroplated Cu coatings was analyzed by electron channeling contrast imaging (ECCI), and its correlation with hardness values was studied. Adhesive failure at the Ni coating/CFRP interface was observed in the absence of a cold-sprayed Cu coating. Enhanced bonding between electroless Ni coating and exposed carbon fiber areas was observed relative to the epoxy regions. This enhanced bonding was attributed to the increased roughness of the carbon fiber regions relative to the epoxy areas. However, after cold spraying with Cu, cohesive failure of the cold-sprayed Cu coating occurred, which was likely due to insufficient plastic deformation of the particles cold sprayed close to the critical velocity of Cu. Electron channeling contrast imaging analysis from the cross sections revealed uniform and inhomogeneous microstructures within the electroplated and cold-sprayed Cu coatings, respectively.
引用
收藏
页码:234 / 248
页数:14
相关论文
共 176 条
[91]  
Kaci A(undefined)undefined undefined undefined undefined-undefined
[92]  
Yandouzi M(undefined)undefined undefined undefined undefined-undefined
[93]  
Fallah P(undefined)undefined undefined undefined undefined-undefined
[94]  
Rajagopalan S(undefined)undefined undefined undefined undefined-undefined
[95]  
McDonald A(undefined)undefined undefined undefined undefined-undefined
[96]  
Yue S(undefined)undefined undefined undefined undefined-undefined
[97]  
Fallah P(undefined)undefined undefined undefined undefined-undefined
[98]  
Chakrabarty R(undefined)undefined undefined undefined undefined-undefined
[99]  
Song J(undefined)undefined undefined undefined undefined-undefined
[100]  
McDonald A(undefined)undefined undefined undefined undefined-undefined