Investigation on Precooling Effects of 4 K Stirling-Type Pulse Tube Cryocoolers

被引:0
|
作者
Qiang Cao
Zimu Li
Mingkai Luan
Zheng Sun
Xiao Tang
Peng Li
Zhenhua Jiang
Li Wei
机构
[1] Tongji University,Institute of Refrigeration and Cryogenics, School of Mechanical Engineering
[2] Tongji University,Shanghai Key Laboratory of Vehicle Aerodynamics and Vehicle Thermal Management Systems
[3] Chinese Academy of Sciences,Shanghai Institute of Technical Physics
[4] Tongji University,Department of Electrical Engineering, School of Electronics and Information Engineering
来源
Journal of Thermal Science | 2019年 / 28卷
关键词
stirling-type pulse tube cryocooler; precooling effects; liquid-helium temperatures;
D O I
暂无
中图分类号
学科分类号
摘要
Stirling-type pulse tube cryocoolers (SPTCs) working at liquid-helium temperatures are appealing in space applications because of their promising advantages such as high reliability, compactness, etc. Worldwide efforts have been put in to develop SPTCs operating at liquid-helium temperatures especially with helium-4 as the working fluid. Staged structure is essential to reach such low temperatures. Generally, both the regenerator of the last section and the pulse tube together with the phase shifter are precooled by its upper stage or by external cold source to a low temperature of around 20 K. However, the precooling effects on the regenerator and the pulse tube are synthetic in previous studies, and their independent effects have not been studied clearly. In this manuscript, the precooling effects on the regenerator and on the pulse tube together with the phase shifter are tested independently on a unique-designed precooled SPTC. The tested precooling temperature is between 13.3 K and 22 K, and the no-load refrigeration temperature gets down to 3.6 K. Further analyses and numerical calculations have been carried out. It is found that the influence on the regenerator is remarkable, which is different from previous conclusions. It is also found that the precooling effects on the pulse tube are relatively weak because of the large pressure-induced enthalpy flow of a real gas working at the temperatures near to the critical point. Furthermore, the phase shifting capacity is analyzed with two cases and with both helium-4 and helium-3 as working fluids, and it keeps quite constant after optimizing the frequency and the precooling temperature for each case. The investigation on these independent effects will provide valid reference on the precooling mechanism study of SPTCs working down to liquid-helium temperatures.
引用
收藏
页码:714 / 726
页数:12
相关论文
共 50 条
  • [31] 15 K two-stage Stirling-type pulse-tube cryocooler
    Yan, Pengda
    Chen, Guobang
    Dong, Jingjing
    Gao, Weili
    CRYOGENICS, 2009, 49 (02) : 103 - 106
  • [32] Advances in High Power Stirling-Type Pulse Tube Cooler
    Sun, Daming
    Chao, Wei
    Sun, Jiuce
    Qiu, Limin
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2010, 20 (03) : 2043 - 2046
  • [33] Numerical and experimental study on the characteristics of 4 K gas-coupled Stirling-type pulse tube cryocooler
    Chen Liubiao
    Wu Xianlin
    Liu Xuming
    Pan Changzhao
    Zhou Yuan
    Wang Junjie
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 88 : 204 - 210
  • [34] Numerical simulation of a three-stage Stirling-type pulse tube cryocooler for 4K operation
    Hu, J. Y.
    Dai, W.
    Luo, E. C.
    Wu, Z. H.
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 53A AND 53B, 2008, 985 : 1531 - 1538
  • [35] 13 K thermally coupled two-stage Stirling-type pulse tube refrigerator
    THUMMES Günter
    ChineseScienceBulletin, 2005, (16) : 144 - 146
  • [36] 13 K thermally coupled two-stage Stirling-type pulse tube refrigerator
    Tang, K
    Chen, GB
    Thummes, G
    CHINESE SCIENCE BULLETIN, 2005, 50 (16): : 1814 - 1816
  • [37] MEASUREMENT AND ANALYSIS OF ENERGY FLOW IN STIRLING-TYPE PULSE TUBE REFRIGERATOR
    Ki, T.
    Jeong, S.
    Seo, M.
    Park, I.
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 57A AND 57B, 2012, 1434 : 555 - 562
  • [38] Investigation on Dynamic Pressure Characteristics of a 5–7 K Three-Stage Stirling-Type Pulse Tube Cryocooler
    Fengshuo, Wen
    Wenting, Wu
    Shaoshuai, Liu
    Jiantang, Song
    Xiao, Tang
    Haifeng, Zhu
    Zhenhua, Jiang
    Yinong, Wu
    Advanced Topics in Science and Technology in China, 2023, 70 : 635 - 641
  • [39] 386 mW/20 K single-stage Stirling-type pulse tube cryocooler
    Chen, Liubiao
    Zhou, Qiang
    Jin, Hai
    Zhu, Wenxiu
    Wang, Junjie
    Zhou, Yuan
    CRYOGENICS, 2013, 57 : 195 - 199
  • [40] High efficiency 40 K single-stage Stirling-type pulse tube cryocooler
    Wu, X. L.
    Chen, L. B.
    Pan, C. Z.
    Cui, C.
    Wang, J. J.
    Zhou, Y.
    ADVANCES IN CRYOGENIC ENGINEERING, 2017, 278