Analysis of four methods of measuring three-dimensional pelvic tilt in the lateral decubitus position

被引:0
作者
Meredith Stadnyk
Tao Liu
Fatemeh Fallahi Arezodar
Lindsey Westover
Jaime A. Carvajal Alba
Edward Masson
Lauren Beaupre
Jacob L. Jaremko
Marwan El-Rich
机构
[1] University of Alberta,Department of Biomedical Engineering
[2] University of Alberta,Department of Mechanical Engineering
[3] Khalifa University,Healthcare Engineering Innovation Center, Department of Mechanical Engineering
[4] University of Alberta,Department of Civil and Environmental Engineering
[5] University of Miami,Department of Orthopaedics
[6] University of Alberta,Department of Surgery
[7] University of Alberta,Department of Physical Therapy
[8] University of Alberta,Department of Radiology and Diagnostic Imaging
来源
Medical & Biological Engineering & Computing | 2020年 / 58卷
关键词
Total hip arthroplasty; Pelvic rotations; Lateral decubitus; Pelvic angle;
D O I
暂无
中图分类号
学科分类号
摘要
Proper alignment of acetabular implantation is necessary for good patient outcomes and preventing complications or additional surgeries in total hip arthroplasty (THA). Rotation of the pelvis in lateral decubitus (LD) is typically not accounted for as surgeons use the surgery table as a reference plane to align implants. This study compared four techniques to measure 3D pelvic rotations in LD position using computer models. CT scans of 19 subjects in LD position were used to create 3D pelvis models. Pelvic rotations were measured by three users using four techniques: landmark (LM), defined plane (DP), anterior pelvic plane (APP), and plane of best symmetry (POBS) methods. Measurements were analysed for intra-user reliability and relationships between methods were assessed using intraclass correlation coefficient, standard error of measurement, and coefficient of determination. The POBS method exhibited the highest inter-observer reliability and is recommended as a new measurement technique to measure pelvic rotations before THA surgery. The LM method exhibited low reliability but may be suitable for expert users familiar with pelvic landmarks. The APP method should only be used when the patients’ APP planes are known in neutral standing and side-lying postures. The DP method is not recommended due to substantial individual variability.
引用
收藏
页码:2387 / 2396
页数:9
相关论文
共 50 条
[31]   Effect of Acetabular Reinforcement Ring With Hook for Acetabular Dysplasia Clarified by Three-Dimensional Finite Element Analysis [J].
Zhao, Xin ;
Chosa, Etsuo ;
Yamako, Go ;
Watanabe, Shinji ;
Deng, Gang ;
Totoribe, Koji .
JOURNAL OF ARTHROPLASTY, 2013, 28 (10) :1765-1769
[32]   Accuracy analysis of artificial intelligence-assisted three-dimensional preoperative planning in total hip replacement [J].
Wu, Long ;
Zhao, Xin ;
Lu, Zhi-Dong ;
Yang, Yong ;
Ma, Long ;
Li, Peng .
JOINT DISEASES AND RELATED SURGERY, 2023, 34 (03) :537-547
[33]   Three-dimensional contact analysis of coupled surfaces by a novel contact transformation method based on localized Lagrange multipliers [J].
Lin, Yi-Tsung ;
Wu, James Shih-Shyn ;
Lai, Yuan-Lung .
ADVANCES IN MECHANICAL ENGINEERING, 2016, 8 (04) :1-13
[34]   Influence of the volume of bone defect, bone grafting methods, and hook fixation on stress on the Kerboull-type plate and screw in total hip arthroplasty: three-dimensional finite element analysis [J].
Kaku N. ;
Hara K. ;
Tabata T. ;
Tsumura H. .
European Journal of Orthopaedic Surgery & Traumatology, 2015, 25 (2) :321-329
[35]   Three-Dimensional Surface Deviation Maps for Analysis of Retrieved Polyethylene Acetabular Liners Using Micro-Computed Tomography [J].
Teeter, Matthew G. ;
Naudie, Douglas D. R. ;
Charron, Kory D. ;
Holdsworth, David W. .
JOURNAL OF ARTHROPLASTY, 2010, 25 (02) :330-332
[36]   Three-dimensional analysis of the cortical contact state of short and conventional stems in different stem positions in total hip arthroplasty [J].
Shoji, Takeshi ;
Saka, Hideki ;
Inoue, Tadashi ;
Kato, Yuichi ;
Fujiwara, Yusuke ;
Yamasaki, Takuma ;
Yasunaga, Yuji ;
Adachi, Nobuo .
CLINICAL BIOMECHANICS, 2021, 83
[37]   Total hip arthroplasty after failed transtrochanteric rotational osteotomy for osteonecrosis of the femoral head: analysis of three-dimensional morphological features [J].
Onaga, Masamichi ;
Nakasone, Satoshi ;
Ishihara, Masato ;
Igei, Takahiro ;
Washizaki, Fumiyuki ;
Kuniyoshi, Sakura ;
Nishida, Kotaro .
BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
[38]   Three-dimensional analysis of the proximal anterior femoral flare and torsion. Anatomic bases for metaphyseally fixed short stems design [J].
Sariali, Elhadi ;
Knaffo, Yohan .
INTERNATIONAL ORTHOPAEDICS, 2017, 41 (10) :2017-2023
[39]   The effect of range of motion simulated with a patient-specific three-dimensional simulation analysis on dislocation after total hip arthroplasty [J].
Mitsutake, Ryo ;
Tanino, Hiromasa ;
Ito, Hiroshi .
HIP INTERNATIONAL, 2023, 33 (02) :313-322
[40]   Total hip arthroplasty after failed transtrochanteric rotational osteotomy for osteonecrosis of the femoral head: analysis of three-dimensional morphological features [J].
Masamichi Onaga ;
Satoshi Nakasone ;
Masato Ishihara ;
Takahiro Igei ;
Fumiyuki Washizaki ;
Sakura Kuniyoshi ;
Kotaro Nishida .
BMC Musculoskeletal Disorders, 25