Analysis of four methods of measuring three-dimensional pelvic tilt in the lateral decubitus position

被引:0
作者
Meredith Stadnyk
Tao Liu
Fatemeh Fallahi Arezodar
Lindsey Westover
Jaime A. Carvajal Alba
Edward Masson
Lauren Beaupre
Jacob L. Jaremko
Marwan El-Rich
机构
[1] University of Alberta,Department of Biomedical Engineering
[2] University of Alberta,Department of Mechanical Engineering
[3] Khalifa University,Healthcare Engineering Innovation Center, Department of Mechanical Engineering
[4] University of Alberta,Department of Civil and Environmental Engineering
[5] University of Miami,Department of Orthopaedics
[6] University of Alberta,Department of Surgery
[7] University of Alberta,Department of Physical Therapy
[8] University of Alberta,Department of Radiology and Diagnostic Imaging
来源
Medical & Biological Engineering & Computing | 2020年 / 58卷
关键词
Total hip arthroplasty; Pelvic rotations; Lateral decubitus; Pelvic angle;
D O I
暂无
中图分类号
学科分类号
摘要
Proper alignment of acetabular implantation is necessary for good patient outcomes and preventing complications or additional surgeries in total hip arthroplasty (THA). Rotation of the pelvis in lateral decubitus (LD) is typically not accounted for as surgeons use the surgery table as a reference plane to align implants. This study compared four techniques to measure 3D pelvic rotations in LD position using computer models. CT scans of 19 subjects in LD position were used to create 3D pelvis models. Pelvic rotations were measured by three users using four techniques: landmark (LM), defined plane (DP), anterior pelvic plane (APP), and plane of best symmetry (POBS) methods. Measurements were analysed for intra-user reliability and relationships between methods were assessed using intraclass correlation coefficient, standard error of measurement, and coefficient of determination. The POBS method exhibited the highest inter-observer reliability and is recommended as a new measurement technique to measure pelvic rotations before THA surgery. The LM method exhibited low reliability but may be suitable for expert users familiar with pelvic landmarks. The APP method should only be used when the patients’ APP planes are known in neutral standing and side-lying postures. The DP method is not recommended due to substantial individual variability.
引用
收藏
页码:2387 / 2396
页数:9
相关论文
共 50 条
  • [21] Three-dimensional analysis of acetabular orientation using a semi-automated algorithm
    Lee, Changhwan
    Jang, Jongseong
    Kim, Hyung Wook
    Kim, Young Soo
    Kim, Yeesuk
    COMPUTER ASSISTED SURGERY, 2019, 24 (01) : 18 - 25
  • [22] Three-Dimensional CT-Based Limb Length Evaluation Is Highly Dependent on Anatomical Landmark Selection and Pelvic Asymmetry
    O'Callaghan, William B.
    Thompson, Matt
    Wuestemann, Thies
    Whitehouse, Sarah L.
    Crawford, Ross W.
    ARTHROPLASTY TODAY, 2023, 23
  • [23] Gait deviations in individuals with inflammatory joint diseases and osteoarthritis and the usage of three-dimensional gait analysis
    Brostrom, Eva W.
    Esbjornsson, Anna-Clara
    von Heideken, Johan
    Iversen, Maura D.
    BEST PRACTICE & RESEARCH IN CLINICAL RHEUMATOLOGY, 2012, 26 (03): : 409 - 422
  • [24] Does total hip arthroplasty restore native hip anatomy? Three-dimensional reconstruction analysis
    Tsai, Tsung-Yuan
    Dimitriou, Dimitris
    Li, Guoan
    Kwon, Young-Min
    INTERNATIONAL ORTHOPAEDICS, 2014, 38 (08) : 1577 - 1583
  • [25] Does total hip arthroplasty restore native hip anatomy? Three-dimensional reconstruction analysis
    Tsung-Yuan Tsai
    Dimitris Dimitriou
    Guoan Li
    Young-Min Kwon
    International Orthopaedics, 2014, 38 : 1577 - 1583
  • [26] Analysis of acetabular orientation and femoral anteversion using images of three-dimensional reconstructed bone models
    Park, Jaeyeong
    Kim, Jun-Young
    Kim, Hyun Deok
    Kim, Young Cheol
    Seo, Anna
    Je, Minkyu
    Mun, Jong Uk
    Kim, Bia
    Park, Il Hyung
    Kim, Shin-Yoon
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2017, 12 (05) : 855 - 864
  • [27] Three-dimensional kinematic analysis of dislocation mechanism in dual mobility total hip arthroplasty constructs
    Klemt, Christian
    Bounajem, Georges
    Tirumala, Venkatsaiakhil
    Xiong, Liang
    Padmanabha, Anand
    Kwon, Young-Min
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2021, 39 (07) : 1423 - 1432
  • [28] Preoperative ultrasound to map the three-dimensional anatomical distribution of the lateral femoral cutaneous nerve in direct anterior approach for total hip arthroplasty
    Yu Zhang
    Yao Yao
    Yexian Wang
    Zaikai Zhuang
    Ying Shen
    Qing Jiang
    Dongyang Chen
    Journal of Orthopaedic Surgery and Research, 16
  • [29] Preoperative ultrasound to map the three-dimensional anatomical distribution of the lateral femoral cutaneous nerve in direct anterior approach for total hip arthroplasty
    Zhang, Yu
    Yao, Yao
    Wang, Yexian
    Zhuang, Zaikai
    Shen, Ying
    Jiang, Qing
    Chen, Dongyang
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [30] Accuracy analysis of artificial intelligence-assisted three-dimensional preoperative planning in total hip replacement
    Wu, Long
    Zhao, Xin
    Lu, Zhi-Dong
    Yang, Yong
    Ma, Long
    Li, Peng
    JOINT DISEASES AND RELATED SURGERY, 2023, 34 (03) : 537 - 547