Protective effect of heparin-coated circuits on the platelets during cardiopulmonary bypass

被引:0
作者
Zhang Kailun
Hu Zhiwei
Yang Yunhai
Huang Ruqing
Fan Huiming
Sun Zongquan
机构
[1] Huazhong University of Science and Technology,Department of Cardiovasular Surgery, Xiehe Hospital, Tongji Medical College
关键词
cardiopulmonary bypass; heparin-coated circuits; platelet;
D O I
10.1007/BF02829429
中图分类号
学科分类号
摘要
To observe the protective effect of heparin-coated circuits (HCC) on the platelet function during cardiopulmonary bypass (CPB). 23 patients with heart valve replacement were studied. The system heparin dose was 3 mg/kg in the control group (n=15) and heparin-coated circuits in the HCC group (n=8). Platelet count, α-granule membrane protein-140 (GMP-140) concentrations were determined before CPB, at 60 min of CPB, 30 and 60 min after protamine administration, first 12 h after CPB, respectively. At end of CPB the arterial filters in the circuits were observed by electron microscopy. The amount of first 12-h postoperative blood loss was measured. There was significant reduction in platelet loss during and after CPB in the HCC group in contrast to the control group during CPB (P<0.05). During the first 12 h, postoperative blood loss was reduced in the HCC group as compared with that in the control group (218±61 ml, vs. 332±118 ml,P<0.05). Electron microscopy showed that in the HCC group the filter meshes and their fringes were clear and fragments of floccules were occasionally seen, without adherent cells or only few adherent cells on their surfaces, whereas several cellular and fibrous components were found to adhere to the surfaces of the filter meshes in the control group. This study indicates that heparin-coated circuits might reduce the platelet loss and activation during CPB and improve hemocompatibility of cardiopulmonary bypass equipment.
引用
收藏
页码:403 / 406
页数:3
相关论文
共 25 条
  • [1] Wahba A(1996)Cardiopulmonary bypass leads to a preferential loss of activated platelets. A flow cytometric assay of platelet surface antigens Eur J Cardiothorac Surg 10 768-768
  • [2] Black G(1999)Coating-techniques to improve the hemocompatibility of artificial diveces used for extracorporeal circulation Eur J Cardiothorac Surg 16 342-342
  • [3] Koksch M(1990)GMP-140 mediates adhesion of stimulated platelets to neutrophils Blood 75 550-550
  • [4] Wendel H P(1993)Comparison of platelet membrane markers for the detection of platelet activation in vitro and during platelet storage and cardiopulmonary bypass surgery J Lab Clin Med 121 579-579
  • [5] Ziemer G(1999)Evaluation of heparin-coated circuits wigth full heparin dose strategy Ann Thorac Cardiovasc Surg 5 156-156
  • [6] Hamburger S A(1996)The effects of Carmeda Bioactive Surface on human blood components during simulated extracoporeal circulation J Thorac Cardiovasc Surg 111 1073-1073
  • [7] McEver R P(1995)High and low heparin dose with hdparin-coated cardiopulmonary bypass: Activation of complement and granulocytes Ann Thorac Surg 60 1755-1755
  • [8] Metzelaar M J(1998)A heparin-coated circuit maintains platelet aggregability in response to shear stress in an in vitro model of cardiopulmonary by-pass Thromb Haemost 80 437-437
  • [9] Korteweg J(1993)Heparin coating reduces blood cell adhesion to arterial filters during coronary bypass; a clinical study Ann Thorac Surg 55 1540-1540
  • [10] Sixma J J(undefined)undefined undefined undefined undefined-undefined