Reference material certification by prompt-gamma activation analysis

被引:0
作者
Richard M. Lindstrom
机构
[1] Analytical Chemistry Division,
[2] National Institute of Standards and Technology,undefined
[3] Gaithersburg,undefined
[4] Maryland 20899,undefined
[5] USA,undefined
来源
Fresenius' Journal of Analytical Chemistry | 1998年 / 360卷
关键词
Radiation; Activation Analysis; Neutron Activation; Neutron Activation Analysis; Instrumental Neutron Activation Analysis;
D O I
暂无
中图分类号
学科分类号
摘要
Neutron-capture prompt-gamma-ray activation analysis (PGAA) shares most of the virtues of instrumental neutron activation analysis (INAA) for reference material certification: highly penetrating probe and response radiation, simple physics, and few interelement interferences or matrix related non-linearities. PGAA complements INAA in determining a different suite of elements using the same tools: a neutron source and gamma-ray spectrometry. Several important elements that are difficult to measure by other techniques are measurable by PGAA, notably H, B, C, N, and S. A survey of published applications and NIST Standard Reference Material certification work shows over thirty different SRMs analyzed by PGAA, including biological materials (botanical and food), coal and fly ash, metals, and several other matrices.
引用
收藏
页码:322 / 324
页数:2
相关论文
共 50 条
[41]   Neutron activation analysis of IAEA proposed certified reference material IAEA-407 (North Sea Fish Homogenate) [J].
M. Wasim ;
A. Rahman ;
J. H. Zaidi ;
S. Waheed ;
S. Ahmad .
Journal of Radioanalytical and Nuclear Chemistry, 2002, 254 :219-222
[42]   Gamma–gamma coincidence in neutron activation analysis [J].
A. Drescher ;
M. Yoho ;
S. Landsberger .
Journal of Radioanalytical and Nuclear Chemistry, 2018, 318 :527-532
[43]   Certification of reference materials for inorganic trace analysis: the INCT approach [J].
Polkowska-Motrenko, Halina ;
Dybczynski, Rajmund S. ;
Chajduk, Ewelina .
ACCREDITATION AND QUALITY ASSURANCE, 2010, 15 (04) :245-250
[44]   Gamma-gamma coincidence in neutron activation analysis [J].
Drescher, A. ;
Yoho, M. ;
Landsberger, S. .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2018, 318 (01) :527-532
[45]   Determination of silver in biological reference materials by neutron activation analysis [J].
J. Mizera ;
Z. Řanda ;
J. Kučera .
Journal of Radioanalytical and Nuclear Chemistry, 2008, 278 :599-602
[46]   Experimental setup for elemental analysis using prompt gamma rays at research reactor IBR-2 [J].
Hramco, C. ;
Turlybekuly, K. ;
Borzakov, S. B. ;
Gundorin, N. A. ;
Lychagin, E., V ;
Nehaev, G., V ;
Muzychka, A. Yu ;
Strelkov, A., V ;
Teymurov, E. .
NUCLEAR ENGINEERING AND TECHNOLOGY, 2022, 54 (08) :2999-3005
[47]   Prompt gamma-ray analysis of chlorine in superpozz cement concrete [J].
Naqvi, A. A. ;
Kalakada, Zameer ;
Al-Matouq, Faris A. ;
Maslehuddin, M. ;
Al-Amoudi, O. S. B. ;
Ur-Rehman, Khateeb .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 693 :67-73
[48]   Trace element determination in a mussel reference material using short irradiation instrumental neutron activation analysis [J].
Moreira, E. G. ;
Seo, D. ;
Vasconcellos, M. B. A. ;
Saiki, M. .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2013, 296 (01) :251-254
[49]   Advantages of synthetic multi-element reference material with pseudo-biological matrix in activation analysis [J].
Y. Iwata ;
N. Suzuki .
Journal of Radioanalytical and Nuclear Chemistry, 1998, 233 :49-53
[50]   Determination of arsenic in a KRISS candidate Oyster Tissue certified reference material by instrumental neutron activation analysis [J].
Kwangwon Park ;
Kyunghaeng Cho ;
Namgoo Kang .
Journal of Radioanalytical and Nuclear Chemistry, 2008, 275 :155-159